Microscale wear behavior and crosslinking of PEG-like coatings for total hip replacements

被引:8
作者
Kane, Sheryl R. [1 ,2 ]
Ashby, Paul D. [3 ]
Pruitt, Lisa A. [1 ,2 ]
机构
[1] UC San Francisco, Joint Grad Grp Bioengn, Berkeley, CA 94720 USA
[2] UC Berkeley, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Lawrence Berkeley Lab, Berkeley, CA 94720 USA
关键词
MOLECULAR-WEIGHT POLYETHYLENE; TOTAL JOINT REPLACEMENTS; PERIPROSTHETIC OSTEOLYSIS; ARTICULAR-CARTILAGE; POLYMER; DEBRIS; ARTHROPLASTY; HYDROGELS;
D O I
10.1007/s10856-009-3935-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The predominant cause of late-state failure of total hip replacements is wear-mediated osteolysis caused by wear particles that originate from the ultrahigh molecular weight polyethylene (UHMWPE) acetabular cup surface. One strategy for reducing wear particle formation from UHMWPE is to modify the surface with a hydrophilic coating to increase lubrication from synovial fluid. This study focuses on the wear behavior of hydrophilic coatings similar to poly(ethylene glycol) (PEG). The coatings were produced by plasma-polymerizing tetraglyme on UHMWPE in a chamber heated to 40A degrees C or 50A degrees C. Both temperatures yielded coatings with PEG-like chemistry and increased hydrophilicity relative to uncoated UHMWPE; however, the 40A degrees C coatings were significantly more resistant to damage induced by atomic force microscopy nanoscratching. The 40A degrees C coatings exhibited only one damage mode (delamination) and often showed no signs of damage after repeated scratching. In contrast, the 50A degrees C coatings exhibited three damage modes (roughening, thinning, and delamination), and always showed visible signs of damage after no more than two scratches. The greater wear resistance of the 40A degrees C coatings could not be explained by coating chemistry or hydrophilicity, but it corresponded to an approximately 26-32% greater degree of crosslinking relative to the 50A degrees C surfaces, suggesting that crosslinking should be a significant design consideration for hydrophilic coatings used for total hip replacements and other wear-dependent applications.
引用
收藏
页码:1037 / 1045
页数:9
相关论文
共 20 条
[1]   The basic science of periprosthetic osteolysis [J].
Archibeck, MJ ;
Jacobs, JJ ;
Roebuck, KA ;
Glant, TT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (10) :1478-1489
[2]   The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene [J].
Baker, DA ;
Bellare, A ;
Pruitt, L .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 66A (01) :146-154
[3]   Study on the tribological properties of pHEMA hydrogels for use in artificial articular cartilage [J].
Bavaresco, V. P. ;
Zavaglia, C. A. C. ;
Reis, M. C. ;
Gomes, J. R. .
WEAR, 2008, 265 (3-4) :269-277
[4]   Comparison of cross-linked polyethylene materials for orthopaedic applications [J].
Collier, JP ;
Currier, BH ;
Kennedy, FE ;
Currier, JH ;
Timmins, GS ;
Jackson, SK ;
Brewer, RL .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (414) :289-304
[5]  
Flory P J., PRINCIPLES POLYM CHE
[6]   Statistical mechanics of cross-linked polymer networks II Swelling [J].
Flory, PJ ;
Rehner, J .
JOURNAL OF CHEMICAL PHYSICS, 1943, 11 (11) :521-526
[7]   Friction, wear, and lubrication of hydrogels as synthetic articular cartilage [J].
Freeman, ME ;
Furey, MJ ;
Love, BJ ;
Hampton, JM .
WEAR, 2000, 241 (02) :129-135
[8]   Biological reactions to wear debris in total joint replacement [J].
Ingham, E ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H1) :21-37
[9]   Plasma deposition and surface characterization of oligoglyme, dioxane, and crown ether nonfouling films [J].
Johnston, EE ;
Bryers, JD ;
Ratner, BD .
LANGMUIR, 2005, 21 (03) :870-881
[10]   Characterization and tribology of PEG-like coatings on UHMWPE for total hip replacements [J].
Kane, Sheryl R. ;
Ashby, Paul D. ;
Pruitt, Lisa A. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2010, 92A (04) :1500-1509