EMAG Institute has specialized in working out the devices for qualitative control of coal. In most cases, they are radiometer appliances taking advantage of absorption or dispersion of gamma radiation of artificial radioactive source or natural radioactivity (ALFA and RODOS Ash Meters). Such methods not always ensure a required accuracy of measurement in case of mineralogical changes of a tested material. In 1980s a PYLOX Meter was worked out in EMAG that makes use of X-ray fluorescence for determining contents of noncombustible solids in mine dust from zones which protect against dust explosions. It was recognised that it is the only method which could allow to measure the quality of hard coal of a very diversified mineralogical contents. Therefore, it was decided to research aimed to determine the usability of PYLOX Meter for measurements of quality of coals from different coal mines and the possibility of improvement of metrological parameters by using semiconductor detectors. Research was conducted on samples originated from Uzbekistan and "Piast" Coal Mine. On the basis of received outcomes, it was stated that accurate determination of qualitative parameters of hard coal in the size grade of 0-3 mm is possible. The accuracy of order of 0,02 % A(a) (ash) and 0,002 % S-t (sulphur) was obtained.
引用
收藏
页码:677 / 685
页数:9
相关论文
共 50 条
  • [1] Application of selected fundamental parameters in x-ray fluorescence analysis
    Zhuo, SJ
    Tao, GY
    Ji, A
    X-RAY SPECTROMETRY, 2003, 32 (01) : 8 - 12
  • [2] Application of nondestructive X-ray fluorescence analysis to determine the element composition of medicinal plants
    Chuparina, E. V.
    Martynov, A. M.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (04) : 389 - 395
  • [3] Application of nondestructive X-ray fluorescence analysis to determine the element composition of medicinal plants
    E. V. Chuparina
    A. M. Martynov
    Journal of Analytical Chemistry, 2011, 66
  • [4] Measurements of K x-ray fluorescence parameters
    Bennal, AS
    Shidling, PD
    Badiger, NM
    Thontadarya, SR
    Hanumaiah, B
    AMERICAN JOURNAL OF PHYSICS, 2005, 73 (09) : 883 - 887
  • [5] Basic fundamental parameters in X-ray fluorescence
    Thomsen, Volker
    SPECTROSCOPY, 2007, 22 (05) : 46 - 50
  • [6] X-ray fluorescence techniques in Czech coal industry
    Cechák, T
    EDXRS-98: PROCEEDINGS OF THE EUROPEAN CONFERENCE ON ENERGY DISPERSIVE X-RAY SPECTROMETRY 1998, 1999, : 329 - 331
  • [7] X-RAY FLUORESCENCE DETERMINATION OF BROWN COAL INORGANICS
    KISS, LT
    ANALYTICAL CHEMISTRY, 1966, 38 (12) : 1731 - &
  • [8] DETERMINATION OF INORGANIC CONSTITUENTS OF COAL BY X-RAY FLUORESCENCE
    ANDERSON, CH
    JONES, RE
    APPLIED SPECTROSCOPY, 1968, 22 (03) : 242 - &
  • [9] The application of x-ray fluorescence analysis with total external reflection for determining the microelements in coal
    Krasnolutskii, VP
    Losev, NF
    Poluyanova, GI
    INDUSTRIAL LABORATORY, 1995, 61 (09): : 531 - 532
  • [10] Glancing angle X-ray fluorescence and its application in X-ray technic
    Dudchik, YI
    Komarov, FF
    Konstantinov, YA
    HARD X-RAY/GAMMA-RAY AND NEUTRON OPTICS, SENSORS, AND APPLICATIONS, 1996, 2859 : 298 - 306