High frequency transducer arrays for medical imaging

被引:0
作者
Ritter, T [1 ]
Shung, KK [1 ]
Tutwiler, R [1 ]
Shrout, T [1 ]
机构
[1] Penn State Univ, NIH, Ctr Med Ultrason Transducer Technol, University Pk, PA 16802 USA
来源
MEDICAL IMAGING 2000: ULTRASONIC IMAGING AND SIGNAL PROCESSING | 2000年 / 3982卷
关键词
transducers; piezoelectric composites; ultrasound arrays; high frequency arrays; imaging arrays;
D O I
10.1117/12.382227
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper discusses the design, fabrication, testing, and simulated imaging performance of high frequency linear arrays. Both a 2-2 PZT composite array with a fine spatial scale and a PbTiO3 array have been investigated at 30 MHz. The composite array demonstrated a seven-fold increase in sensitivity over the PbTiO3 array, as well as increased bandwidth and reduced crosstalk. The electrical impedance magnitude of the composite array was 56 ohms at 30 MHz, and the measured insertion loss was -14 dB. Simulated results demonstrate excellent lateral and axial resolution when imaging a phantom using a synthetic aperture approach. A 35 MHz device is also under development. An interconnect method using a flex circuit and sputtered metal films is used to electrically connect to each element. A curve fitting technique was then used to characterize elements of the array. Electromechanical coupling coefficients from 0.55 to 0.62 and clamped relative permittivities (epsilon(33)(S)'/epsilon(0)) from 1200 to 2000 were observed.
引用
收藏
页码:208 / 216
页数:9
相关论文
共 23 条
  • [1] LENS IN THE NEARFIELD OF A CIRCULAR TRANSDUCER - GAUSSIAN-LAGUERRE FORMULATION
    CAVANAGH, E
    COOK, BD
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1981, 69 (02) : 345 - 351
  • [2] CORI PD, 1978, 1978 IEEE ULTR S, P263
  • [3] Two-dimensional arrays for medical ultrasound using multilayer flexible circuit interconnection
    Davidsen, RE
    Smith, SW
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (02) : 338 - 348
  • [4] DESILETS CS, 1978, 2833 EL GINZT LAB
  • [5] Guess JF, 1995, ULTRASON, P1279, DOI 10.1109/ULTSYM.1995.495790
  • [6] A 100-MHZ ULTRASONIC TRANSDUCER ARRAY USING ZNO THIN-FILMS
    ITO, Y
    KUSHIDA, K
    SUGAWARA, K
    TAKEUCHI, H
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (02) : 316 - 324
  • [7] Jensen J. A., 1996, MED BIOL ENG COMPUT, V34, P351
  • [8] Kwok KW, 1997, IEEE T ULTRASON FERR, V44, P733, DOI 10.1109/58.655188
  • [9] LETHIECQ M, 1994, ULTRASON, P1009, DOI 10.1109/ULTSYM.1994.401708
  • [10] Beyond 30 MHz - Applications of high-frequency ultrasound imaging
    Lockwood, GR
    Turnbull, DH
    Christopher, DA
    Foster, FS
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (06): : 60 - 71