Carbon dioxide kinetics and capnography during critical care

被引:85
作者
Anderson, CT [1 ]
Breen, PH [1 ]
机构
[1] Univ Calif Irvine, Med Ctr, Dept Anesthesiol, Orange, CA 92868 USA
来源
CRITICAL CARE | 2000年 / 4卷 / 04期
关键词
airway; capnography; carbon dioxide; carbon dioxide kinetics; expirogram; nonsteady state; ventilation;
D O I
10.1186/cc696
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Greater understanding of the pathophysiology of carbon dioxide kinetics during steady and nonsteady state should improve, we believe, clinical care during intensive care treatment. Capnography and the measurement of end-tidal partial pressure of carbon dioxide (PETCO2) will gradually be augmented by relatively new measurement methodology, including the volume of carbon dioxide exhaled per breath (VCO2,br) and average alveolar expired PCO2 (P<(AE)over bar>CO2). Future directions include the study of oxygen kinetics.
引用
收藏
页码:207 / 215
页数:9
相关论文
共 61 条
[1]   Noninvasive capnometry monitoring for respiratory status during pediatric seizures [J].
Abramo, TJ ;
Wiebe, RA ;
Scott, S ;
Goto, CS ;
McIntire, DD .
CRITICAL CARE MEDICINE, 1997, 25 (07) :1242-1246
[2]   Single breath CO2 analysis: Description and validation of a method [J].
Arnold, JH ;
Thompson, JE ;
Arnold, LW .
CRITICAL CARE MEDICINE, 1996, 24 (01) :96-102
[3]   PROGNOSTIC VALUE OF END-TIDAL CARBON-DIOXIDE PRESSURES DURING OUT-OF-HOSPITAL CARDIAC-ARREST [J].
ASPLIN, BR ;
WHITE, RD .
ANNALS OF EMERGENCY MEDICINE, 1995, 25 (06) :756-761
[4]  
BIRMINGHAM PK, 1986, ANESTH ANALG, V65, P886
[5]   EFFECT OF PEEP ON THE ARTERIAL MINUS END-TIDAL CARBON-DIOXIDE GRADIENT [J].
BLANCH, L ;
FERNANDEZ, R ;
BENITO, S ;
MANCEBO, J ;
NET, A .
CHEST, 1987, 92 (03) :451-454
[6]  
BLANCH L, 1988, INTENS CARE MED, V14, P131
[7]   How does experimental pulmonary embolism decrease CO2 elimination [J].
Breen, PH ;
Mazumdar, B ;
Skinner, SC .
RESPIRATION PHYSIOLOGY, 1996, 105 (03) :217-224
[8]   Comparison of end-tidal Pco(2) and average alveolar expired Pco(2) during positive end-expiratory pressure [J].
Breen, PH ;
Mazumdar, B ;
Skinner, SC .
ANESTHESIA AND ANALGESIA, 1996, 82 (02) :368-373
[9]   Measurement of pulmonary CO2 elimination must exclude inspired CO2 measured at the capnometer sampling site [J].
Breen, PH ;
Serina, ER ;
Barker, SJ .
JOURNAL OF CLINICAL MONITORING, 1996, 12 (03) :231-236
[10]   SIMPLE COMPUTER MEASUREMENT OF PULMONARY VCO2 PER BREATH [J].
BREEN, PH ;
ISSERLES, SA ;
HARRISON, BA ;
ROIZEN, MF .
JOURNAL OF APPLIED PHYSIOLOGY, 1992, 72 (05) :2029-2035