Rapid measurement of Gd-DTPA extraction fraction in a dialysis system using echo-planar imaging

被引:16
作者
Niendorf, ER [1 ]
Grist, TM
Frayne, R
Brazy, PC
Santyr, GE
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53705 USA
[2] Carleton Univ, Dept Phys, Ottawa, ON K1S 5B6, Canada
[3] Univ Wisconsin, Dept Radiol, Madison, WI 53705 USA
[4] Univ Wisconsin, Dept Nephrol, Madison, WI 53705 USA
关键词
MRI; glomerular filtration rate; Gd-DTPA; renal filtration fraction; dialysis;
D O I
10.1118/1.598104
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Gd-DTPA (Magnevist, Berlex, Wayne, NJ) extraction fractions (EF) have been measured for three dialysis filter types using an echo-planar imaging (EPI) Look-Locker T-1 measurement technique under conditions of fast and slow flow. The mean EF measured in Fresenius (Bad Homburg, Germany) F3, F6, and F8 dialysis filters were 0.015+/-0.005, 0.053+/-0.004, and 0.084+/-0.003, respectively, under conditions of fast flow which provided complete refreshment of spins in the intervals between read-out pulse samples of the T-1 relaxation recovery. Data acquisition and post processing techniques were developed to extend the accuracy of the LL technique to systems with slow how which did not provide complete refreshment of spins between samples of the T-1 recovery. A multi-shot EPI LL interleaved acquisition of relaxation recovery space (IRRS) provided T-1 measurement accuracy comparable to the refreshed system, +/- 10, but at the expense of increased scan times (factor of 2 or 3). Discarding the first few non-equilibrium relaxation recovery samples from the T-1 fit allowed accurate T-1 estimation (+/-10) with a single-shot EPI LL method under conditions of slow flow. These EPI LL EF measurement methods may provide useful techniques for evaluating renal function in vivo. (C) 1997 American Association of Physicists in Medicine.
引用
收藏
页码:1907 / 1913
页数:7
相关论文
共 10 条
  • [1] EVALUATION OF RENAL-FUNCTION
    BECKER, JA
    [J]. RADIOLOGY, 1991, 179 (02) : 337 - 338
  • [2] NONINVASIVE MEASUREMENT OF RENAL HEMODYNAMIC FUNCTIONS USING GADOLINIUM-ENHANCED MAGNETIC-RESONANCE-IMAGING
    DUMOULIN, CL
    BUONOCORE, MH
    OPSAHL, LR
    KATZBERG, RW
    DARROW, RD
    MORRIS, TW
    BATEY, C
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) : 370 - 378
  • [3] NMR RELAXATION-TIMES OF BLOOD - DEPENDENCE ON FIELD-STRENGTH, OXIDATION-STATE, AND CELL INTEGRITY
    GOMORI, JM
    GROSSMAN, RI
    YUIP, C
    ASAKURA, T
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (04) : 684 - 690
  • [4] Guyton AC, 1991, TXB MED PHYSL
  • [5] Look D. C., 1970, Review of Scientific Instruments, V41, P250, DOI 10.1063/1.1684482
  • [6] Measurement of Gd-DTPA dialysis clearance rates by using a look-locker imaging technique
    Niendorf, ER
    Santyr, GE
    Brazy, PC
    Grist, TM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) : 571 - 578
  • [7] PRESS HW, 1992, NUMERICAL RECIPES
  • [8] Rideout VC, 1991, MATH COMPUTER MODELI
  • [9] FAST 3-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY OF THE INTRACRANIAL VASCULATURE
    TALAGALA, SL
    JUNGREIS, CA
    KANAL, E
    MEYERS, SP
    FOO, TKF
    RUBIN, RA
    APPLEGATE, GR
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 317 - 323
  • [10] PREDICTION OF GLOMERULAR-FILTRATION RATE FROM SERUM CREATININE CONCENTRATION IN ADVANCED CHRONIC-RENAL-FAILURE
    WALSER, M
    DREW, HH
    GULDAN, JL
    [J]. KIDNEY INTERNATIONAL, 1993, 44 (05) : 1145 - 1148