A novel quartz crystal microbalance sensor array based on molecular imprinted polymers for simultaneous detection of clenbuterol and its metabolites

被引:58
作者
Feng, Fan [1 ]
Zheng, Jianwu [1 ]
Qin, Peng [2 ]
Han, Tao [2 ]
Zhao, Dayun [1 ,3 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Food Sci & Technol, 800 Dongchuan Rd, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, Dept Instrument Sci & Engn, 800 Dongchuan Rd, Shanghai 200240, Peoples R China
[3] Shanghai Jiao Tong Univ, Bor S Luh Food Safety Res Ctr, 800 Dongchuan Rd, Shanghai 200240, Peoples R China
关键词
Clenbuterol; Metabolites; Molecularly imprinted polymer; Quartz crystal microbalance (QCM); Sensor array; PERFORMANCE LIQUID-CHROMATOGRAPHY; GAS; EXTRACTION; QCM; PHASE; FILMS;
D O I
10.1016/j.talanta.2017.02.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the rapid and robust detection of both parent clenbuterol (CLB) and its metabolites in swine urine samples, a novel quartz crystal microbalance (QCM) sensor array for CLB detection based on molecularly imprinted polymers (MIPs) was developed in this investigation. At first, clenbuterol and the structural analogs of its metabolites, 4-Aminohippuric acid (AHA) and 4-hydroxymandelic acid (HMA), were chosen as molecular templates. Through computational molecular modeling, the optimum ratio between the functional monomer and molecular template was selected. The surface imprinting method was applied to modify QCM electrode surface to graft a thin MIP film. The grafting polymer was characterized by Fourier-transformed infrared spectrometry (FTIR) and atomic force microscopy (AFM), respectively. After then, an array system composed of three sensors was employed to test the responses with different solutions and the principal component analysis (PCA) was adopted to analyze the corresponding data. As a result, for the designed sensor to clenbuterol, a linear equation y=100.07x-722.96 (R-2=0.9928) was found between the sensor frequency shift OF and negative logarithm of clenbuterol concentration (-lgC). The limitation of detection (LOD) was 3.0 ng/mL, which is lower than the Codex Alimentarius Commission regulations residue limit 10 mu g/L. The corresponding data of the three template solutions were analyzed by PCA, obtaining 100% recognition. The result demonstrated the feasibility that the developed method could be applied to detect whether the livestock was feed with CLB nutrient redistribution agent by checking the urine samples.
引用
收藏
页码:94 / 102
页数:9
相关论文
共 38 条
  • [1] A solid binding matrix/molecularly imprinted polymer-based sensor system for the determination of clenbuterol in bovine liver using differential-pulse voltammetry
    Andrea, P
    Miroslav, S
    Silvia, S
    Stanislav, M
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3) : 286 - 294
  • [2] Potentiometric detection of N,N-diethylaminoethanol and lysosomotropic amino alcohols in cation exchange high-performance liquid chromatography systems
    Bazylak, G
    Nagels, LJ
    [J]. ANALYTICA CHIMICA ACTA, 2002, 472 (1-2) : 11 - 26
  • [3] Extraction of clenbuterol from calf urine using a molecularly imprinted polymer followed by quantitation by high-performance liquid chromatography with UV detection
    Blomgren, A
    Berggren, C
    Holmberg, A
    Larsson, F
    Sellergren, B
    Ensing, K
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 975 (01) : 157 - 164
  • [4] Selective optosensing of clenbuterol and melamine using molecularly imprinted polymer-capped CdTe quantum dots
    Bui The Huy
    Seo, Min-Ho
    Zhang, Xinfeng
    Lee, Yong-Ill
    [J]. BIOSENSORS & BIOELECTRONICS, 2014, 57 : 310 - 316
  • [5] Chang LY, 2005, J FOOD DRUG ANAL, V13, P163
  • [6] Short, strong hydrogen bonds in the gas phase and in solution:: Theoretical exploration of pKa matching and environmental effects on the strengths of hydrogen bonds and their potential roles in enzymatic catalysis
    Chen, JG
    McAllister, MA
    Lee, JK
    Houk, KN
    [J]. JOURNAL OF ORGANIC CHEMISTRY, 1998, 63 (14) : 4611 - 4619
  • [7] Amplified QCM-D biosensor for protein based on aptamer-functionalized gold nanoparticles
    Chen, Qiang
    Tang, Wei
    Wang, Dingzhong
    Wu, Xiaojie
    Li, Na
    Liu, Feng
    [J]. BIOSENSORS & BIOELECTRONICS, 2010, 26 (02) : 575 - 579
  • [8] Sample Preincubation Strategy for Sensitive and Quantitative Detection of Clenbuterol in Swine Urine Using a Fluorescent Microsphere-Based Immunochromatographic Assay
    Deng, Sheng L.
    Shan, Shan
    Xu, Chao L.
    Liu, Dao F.
    Xiong, Yong H.
    Wei, Hua
    Lai, Wei H.
    [J]. JOURNAL OF FOOD PROTECTION, 2014, 77 (11) : 1998 - 2003
  • [9] Detection of main urinary metabolites of β2-agonists clenbuterol, salbutamol and terbutaline by liquid chromatography high resolution mass spectrometry
    Dominguez-Romero, Juan C.
    Garcia-Reyes, Juan F.
    Martinez-Romero, Ruben
    Martinez-Lara, Esther
    Del Moral-Leal, Maria L.
    Molina-Diaz, Antonio
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 923 : 128 - 135
  • [10] β2-agonist extraction procedures for chromatographic analysis
    dos Ramos, FJ
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 880 (1-2) : 69 - 83