Measurement Reliability of Axial Length of the Human Eye by using Partial Coherence Interferometry

被引:1
|
作者
Kim, Jae-Hyung [1 ]
Moon, Tae Hwan [1 ]
Chae, Ju Byung [1 ]
Hyung, Sungmin [1 ]
机构
[1] Chungbuk Natl Univ, Coll Med, Dept Ophthalmol, Cheongju 361711, South Korea
关键词
Axial length; Malus' law; Media opacity; Partial coherence interferometry; Polarizing lens; CATARACT DENSITY; BIOMETRY; DEVICE;
D O I
10.3807/JOSK.2014.18.5.546
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
To investigate the minimum near-infrared ray intensity required (quantifiable threshold value) for consistent measurements of axial length (AL) using partial coherence interferometry (PO), we attached two polarizing lenses (PL) to two types of PCI (IOLmaster, ALscan). The near-infrared ray intensity of PCI was modified by rotating the axis of one PL at intervals of 5 degrees. The right eye of each volunteer was measured three times and the AL and signal-to-noise ratio (SNR) was recorded five times for each measurement. Reduction of light intensity was theoretically estimated using Malus' Law. AL was measured consistently with both IOLmaster and ALscan until they reached 55 degrees (1.33 % of intensity) and 60 degrees (0.77%), respectively (P = 0.343, Log-rank test). In contrast, SNR decreased as light intensity decreased. In addition, to analyze media opacities that precluded measurement of AL, we retrospectively reviewed the medical records of patients unmeasurable by PCI (ALscan) from May to November 2013. Thirty-eight of 473 eyes (8.0%) could not be measured using ALscan due to media opacities, such as severe posterior subcapsular cataract (PSC, 11 eyes), hypermature cataract (9 eyes), and vitreous hemorrhage (18 eyes). The mean grades of vitreous haze and PSC were 7.72 +/- 0.96 and 4.45 +/- 1.04, respectively. In conclusion, up to 0.77-1.33% of near-infrared rays decreased, and AL could be measured consistently.
引用
收藏
页码:546 / 550
页数:5
相关论文
共 50 条
  • [1] Application of diffractive optics for axial eye length measurement using partial coherence interferometry
    Moller, B
    Rudolph, G
    Klopffleisch, A
    Donnerhacke, KH
    Dorsel, A
    LASERS IN OPHTHALMOLOGY IV, PROCEEDINGS OF, 1996, 2930 : 175 - 182
  • [2] Reliability and validity of the partial coherence interferometry for measurement of ocular axial length in children
    H M Hussin
    P G D Spry
    M A Majid
    P Gouws
    Eye, 2006, 20 : 1021 - 1024
  • [3] Reliability and validity of the partial coherence interferometry for measurement of ocular axial length in children
    Hussin, H. M.
    Spry, P. G. D.
    Majid, M. A.
    Gouws, P.
    EYE, 2006, 20 (09) : 1021 - 1024
  • [4] Evaluation of Axial Length Measurement of the Eye Using Partial Coherence Interferometry and Ultrasound in Cases of Macular Disease
    Kojima, Takashi
    Tamaoki, Akeno
    Yoshida, Norihiko
    Kaga, Tatsushi
    Suto, Chikako
    Ichikawa, Kazuo
    OPHTHALMOLOGY, 2010, 117 (09) : 1750 - 1754
  • [5] Comparison of eye length measurement using partial coherence interferometry and clinical ultrasound
    Greenberg, KP
    Francis, EL
    Allam, A
    Desai, A
    Ying, GS
    Stone, RA
    Quinn, GE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U287 - U287
  • [6] Axial Eye Length Measurement System Based on Low Coherence Interferometry
    Wang Cheng
    Zhou Qi
    Chen Yijun
    Chen Minghui
    Xiang Huazhong
    Zheng Gang
    Zhao Jie
    Zhang Dawei
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2022, 49 (05):
  • [7] Axial Eye Length Measurement System Based on Low Coherence Interferometry
    Wang C.
    Zhou Q.
    Chen Y.
    Chen M.
    Xiang H.
    Zheng G.
    Zhao J.
    Zhang D.
    Zhongguo Jiguang/Chinese Journal of Lasers, 2022, 49 (05):
  • [8] Comparison of Eye Axial Length Measurements Taken Using Partial Coherence Interferometry and OCT Biometry
    Rizzieri, Nicola
    Facchin, Alessio
    VISION, 2024, 8 (03)
  • [9] Partial coherence interferometry versus immersion ultrasonography for axial length measurement in children
    Lenhart, Phoebe D.
    Hutchinson, Amy K.
    Lynn, Michael J.
    Lambert, Scott R.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (12): : 2100 - 2104
  • [10] High sensitive measurement of the human axial eye length in vivo with Fourier domain low coherence interferometry
    Grajciar, Branislav
    Pircher, Michael
    Hitzenberger, Christoph K.
    Findl, Oliver
    Fercher, Adolf F.
    OPTICS EXPRESS, 2008, 16 (04) : 2405 - 2414