Impedimetric label-free sensor for specific bacteria endotoxin detection by surface charge registration

被引:29
|
作者
Brosel-Oliu, Sergi [1 ]
Galyamin, Dmitry [1 ]
Abramova, Natalia [1 ,2 ]
Munoz-Pascual, Francesc-Xavier [1 ]
Bratov, Andrey [1 ]
机构
[1] CSIC, Ctr Nacl Microelect IMB CNM, Inst Microelect Barcelona, BioMEMS Grp,Esfera UAB CEI, Campus UAB, Barcelona 08193, Spain
[2] ITMO Univ, Lab Artificial Sensors Syst, Kronverskiy Pr 49, St Petersburg 197101, Russia
关键词
Impedimetric sensor; Surface charge; Interdigitated electrode array; Bacterial endotoxin; Concanavalin A; QUARTZ-CRYSTAL MICROBALANCE; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; INTERDIGITATED ELECTRODE ARRAY; CONCANAVALIN-A; LECTIN; BIOSENSOR; CARBOHYDRATE; ADSORPTION; PROTEIN; SAMPLES;
D O I
10.1016/j.electacta.2017.05.060
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
An impedimetric sensor based on a three dimensional electrode array modified with concanavalin A (Con A) was used for label-free detection of bacterial endotoxin: lipopolysaccharide (LPS) from Escherichia coli. The transducer permits the detection of the surface charge changes due to interaction of immobilized Con A biorecognition element and LPS of E. coli in test solution. The deposition of Con A on the surface was carried out using the layer-by-layer method with polyethyleneimine (PEI) polycation as an initial layer. The sensor surface characterization by means of electrochemical impedance spectroscopy technique allowed registering variations in superficial resistance provoked by surface charge changes and is demonstrated as an effective method to monitor sensor parameters at each modification step as well as to follow Con A - LPS reaction. In order to prevent non-specific adsorption of LPS on PEI covered surface different blocking strategies were tested to achieve the specific response between Con A and LPS. Results obtained in this work clearly show that blocking with bovine serum albumin (BSA) is not sufficient to prevent non-specific interactions of PEI and to ensure the selective biorecognition of LPS by Con A. To achieve more efficient PEI blocking a new method was proposed based on consecutive deposition of Con A-glycogen-Con A layers. Sensors modified with PEI-(Con A-Gly)(2)-Con A multilayers are shown to be highly sensitive, selective and reproducible. Presented biosensor is able to detect bacterial LPS in a very short detection time (20 min) with 2 mu g mL(-1) limit of detection, which is much lower than reported for other biosensors with Con A. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:142 / 151
页数:10
相关论文
共 50 条
  • [1] Development of a label-free impedimetric aptasensor for the detection of Acinetobacter baumannii bacteria
    Abedi, Rokhsareh
    Raoof, Jahan Bakhsh
    Mohseni, Mojtaba
    Hashkavayi, Ayemeh Bagheri
    ANALYTICAL BIOCHEMISTRY, 2023, 679
  • [2] An impedimetric immunosensor for the label-free detection of bisphenol A
    Rahman, Md. Aminur
    Shiddiky, Muhammad J. A.
    Park, Jang-Su
    Shim, Yoon-Bo
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (11): : 2464 - 2470
  • [3] Label-Free Electrochemical Immunoaffinity Sensor Based on Impedimetric Method for Pesticide Detection
    Tran, H. V.
    Reisberg, S.
    Piro, B.
    Nguyen, T. D.
    Pham, M. C.
    ELECTROANALYSIS, 2013, 25 (03) : 664 - 670
  • [4] Label-free impedimetric immunosensor for sensitive detection of atrazine
    Ionescu, Rodica E.
    Gondran, Chantal
    Bouffier, Laurent
    Jaffrezic-Renault, Nicole
    Martelet, Claude
    Cosnier, Serge
    ELECTROCHIMICA ACTA, 2010, 55 (21) : 6228 - 6232
  • [5] Label-free impedimetric immunosensor for sensitive detection of ochratoxin A
    Radi, Abd-Elgawad
    Munoz-Berbel, Xavier
    Lates, Vasilica
    Marty, Jean-Louis
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (07): : 1888 - 1892
  • [6] A new label-free impedimetric aptasensor for gluten detection
    Malvano, Francesca
    Albanese, Donatella
    Pilloton, Roberto
    Di Matteo, Marisa
    FOOD CONTROL, 2017, 79 : 200 - 206
  • [7] Label-Free Cancer Cell Detection with Impedimetric Transducers
    de la Rica, Roberto
    Thompson, Sebastian
    Baldi, Antonio
    Fernandez-Sanchez, Cesar
    Drain, Charles Michael
    Matsui, Hiroshi
    ANALYTICAL CHEMISTRY, 2009, 81 (24) : 10167 - 10171
  • [8] A Reusable Sensor for the Label-Free Detection of Specific Oligonucleotides by Surface Plasmon Fluorescence Spectroscopy
    Noell, Gilbert
    Su, Qiang
    Heidel, Bjoern
    Yu, Yaming
    ADVANCED HEALTHCARE MATERIALS, 2014, 3 (01) : 42 - 46
  • [9] Label-free impedimetric immunosensor for sensitive detection of fenvalerate in tea
    Wang, Meirong
    Kang, Huimin
    Xu, Dan
    Wang, Chengyin
    Liu, Shuzhao
    Hu, Xiaoya
    FOOD CHEMISTRY, 2013, 141 (01) : 84 - 90
  • [10] An Ultrasensitive Field Effect Charge Sensor for Label-free Biomolecule Detection
    Shao, Shiqian
    Wang, Yi
    2009 LASERS & ELECTRO-OPTICS & THE PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, VOLS 1 AND 2, 2009, : 1270 - 1271