Long-term results of implantation of phakic posterior chamber intraocular lenses

被引:134
作者
Lackner, B [1 ]
Pieh, S [1 ]
Schmidinger, G [1 ]
Simader, C [1 ]
Franz, C [1 ]
Dejaco-Ruhswurm, I [1 ]
Skorpik, C [1 ]
机构
[1] Univ Vienna, Dept Ophthalmol, A-1090 Vienna, Austria
关键词
D O I
10.1016/j.jcrs.2004.07.018
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To study the incidence and progression of lens opacification after implantation of phakic posterior chamber intraocular lenses for myopia and its correlation with vaulting and endothelial cell density (ECD). Setting: Department of Ophthalmology, University of Vienna Medical School, Vienna, Austria. Methods: An implantable contact lens (ICL V4, Staar Surgical Inc.) was inserted in 76 myopic eyes. Patients were prospectively followed preoperatively and at 1, 3, 6, 12, 24, and 36 months. The uncorrected visual acuity and best corrected visual acuity (BCVA) were determined. Vaulting was measured optically with a Jaeger II pachymeter, and the crystalline lens was examined at the slitlamp for the presence and characteristics of opacification. Endothelial cell morphometry was performed by specular microscopy, and the ECD was calculated. Eyes in which lens opacification developed were followed for at least 12 months to determine the degree and course of visual impairment. Results: Lens opacification occurred in 11 eyes (114.5%). Opacification was correlated with intraoperative trauma to the crystalline lens, age older than 50 years, and decreased ECD values throughout the observation period. Vaulting of the ICL did not correlate with the risk for lens opacification. After onset of lens opacification, 6 eyes (55%) had a stable BCVA within +/-0.5 lines and 5 eyes had progressive opacification, losing between 3.5 lines and 0.5 lines (mean 1.8 lines 1.1 [SD]). Three eyes (3.9%) in the progressive group had a 1- to 2-line loss of BCVA over preoperative values and subsequently had cataract surgery. Conclusions: Risk factors for lens opacification after implantation of the model V4 ICL included intraoperative trauma to the crystalline lens and older age. Decreased ECD in eyes with opacification suggests ongoing inflammation as a cause. Patients younger than 45 years may have a significantly lower incidence of opacification. (C) 2004 ASCRS and ESCRS.
引用
收藏
页码:2269 / 2276
页数:8
相关论文
共 27 条
[1]   Gonioscopic changes after implantation of a posterior chamber lens in phakic myopic eyes [J].
Abela-Formanek, C ;
Kruger, AJ ;
Dejaco-Ruhswurm, I ;
Pieh, S ;
Skorpik, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (12) :1919-1925
[2]   Collamer intraocular contact lens to correct high myopia [J].
Assetto, V ;
Benedetti, S ;
Pesando, P .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (05) :551-556
[3]   Imaging of posterior chamber phakic intraocular lens by optical coherence tomography [J].
Bechmann, M ;
Ullrich, S ;
Thiel, MJ ;
Kenyon, KR ;
Ludwig, K .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :360-363
[4]   Effects of laser in situ keratomileusis (LASIK) on the corneal endothelium 3 years postoperatively [J].
Collins, MJ ;
Carr, JD ;
Stulting, RD ;
Azar, RG ;
Waring, GO ;
Smith, RE ;
Thompson, KP ;
Edelhauser, HF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2001, 131 (01) :1-6
[5]   Long-term endothelial changes in phakic eyes with posterior chamber intraocular lenses [J].
Dejaco-Ruhswurm, I ;
Scholz, U ;
Pieh, S ;
Hanselmayer, G ;
Lackner, B ;
Italon, C ;
Ploner, M ;
Skorpik, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (09) :1589-1593
[6]   Cataract development after implantation of the Staar Collamer posterior chamber phakic lens [J].
Fink, AM ;
Gore, C ;
Rosen, E .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (02) :278-282
[7]   Implantable contact lens for moderate to high myopia - Relationship of vaulting to cataract formation [J].
Gonvers, M ;
Bornet, C ;
Othenin-Girard, P .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (05) :918-924
[8]   Implantable contact lens for moderate to high myopia - Short-term follow-up of 2 models [J].
Gonvers, M ;
Othenin-Girard, P ;
Bornet, C ;
Sickenberg, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (03) :380-388
[9]   Comparison of confocal biomicroscopy and noncontact specular microscopy for evaluation of the corneal endothelium [J].
Hara, M ;
Morishige, N ;
Chikama, T ;
Nishida, T .
CORNEA, 2003, 22 (06) :512-515
[10]   Safety of posterior chamber phakic intraocular lenses for the correction of high myopia -: Anterior segment changes after posterior chamber phakic intraocular lens implantation [J].
Jiménez-Alfaro, I ;
del Castillo, JMB ;
García-Feijoó, J ;
de Bernabé, JGG ;
de la Iglesia, JMS .
OPHTHALMOLOGY, 2001, 108 (01) :90-99