Bond Efficacy and Interface Morphology of Self-etching Adhesives to Ground Enamel

被引:22
|
作者
Abdalla, Ali I. [1 ]
El Zohairy, Ahmed A. [2 ]
Mohsen, Mohamed M. Abdel
Feilzer, Albert J. [3 ,4 ]
机构
[1] Tanta Univ, Fac Dent, Dept Restorat Dent, Tanta, Egypt
[2] Cairo Univ, Fac Dent, Dept Operat Dent, Cairo, Egypt
[3] Univ Amsterdam, Dept Dent Mat Sci, ACTA, Amsterdam, Netherlands
[4] Vrije Univ Amsterdam, Amsterdam, Netherlands
关键词
bond strength; self-etching adhesives; microshear; BUR-CUT ENAMEL; CLINICAL-EVALUATION; PRISM ORIENTATION; RESIN COMPOSITE; STRENGTH; DENTIN; SYSTEMS; PRIMER;
D O I
10.3290/j.jad.a17527
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study compared the microshear bond strengths to ground enamel of three one-step self-etching adhesive systems, a self-etching primer system and an etch-and-rinse adhesive system. Materials and Methods: Three self-etching adhesives, Futurabond DC (Voco), Clearfil S Tri Bond (Kuraray) and Hybrid bond (Sun-Medical), a self-etching primer, Clearfil SE Bond (Kuraray), and an etch-and-rinse system, Admira Bond (Voco), were selected. Thirty human molars were used. The root of each tooth was removed and the crown was sectioned into halves. The convex enamel surfaces were reduced by polishing on silicone paper to prepare a flat surface. The bonding systems were applied on this surface. Prior to adhesive curing, a hollow cylinder (2.0 mm height/0.75 mm internal diameter) was placed on the treated surfaces. A resin composite was then inserted into the tube and cured. After water storage for 24 h, the tube was removed and shear bond strength was determined in a universal testing machine at a crosshead speed of 0.5 mm/min. The results were analyzed with ANOVA and the Tukey.-Kramer test at a 59 degrees confidence level. The enamel of five additional teeth was ground, and the etching component of each adhesive was applied and removed with absolute ethanol instead of being light cured. These teeth and selected fractured surfaces were examined by SEM. Results: Adhesion to ground enamel of the Futurabond DC (25 +/- 3.5 MPa) and Clearfil SE Bond (23 +/- 2.9 MPa) self-etching systems was not significantly different from the etch-and-rinse system Admira Bond (27 +/- 2.3 MPa). The two self-etching adhesives Clearfil S Tri bond and Hybrid Bond demonstrated significantly lower bond strengths (14 +/- 1.4 MPa; 11 +/- 1.9 MPa) with no significant differences between them (p < 0.05). Conclusion: Bond strengths to ground enamel of self-etching adhesive systems are dependant on the type of adhesive system. Some of the new adhesive systems showed bond strength values comparable to that of etch-and-rinse systems. There was no correlation between bond strength and morphological changes in enamel.
引用
收藏
页码:19 / 25
页数:7
相关论文
共 50 条
  • [11] Effect of oxygen inhibition of self-etching adhesives on enamel-dentin polymer bond
    Endo, Tatsuo
    Osada, Takayuki
    Finger, Werner J.
    Hoffmann, Marcus
    Kanehira, Masafumi
    Komatsu, Masashi
    JOURNAL OF ADHESIVE DENTISTRY, 2007, 9 (01) : 33 - 38
  • [12] BOND STRENGTH DURABILITY OF SELF-ETCHING ADHESIVES AND RESIN CEMENTS TO DENTIN
    Lima Chaves, Carolina de Andrade
    de Melo, Renata Marques
    Passos, Sheila Pestana
    Camargo, Fernanda Pelogia
    Bottino, Marco Antonio
    Balducci, Ivan
    JOURNAL OF APPLIED ORAL SCIENCE, 2009, 17 (03) : 155 - 160
  • [13] Influence of Methods of Application of Self-etching Adhesive Systems on Adhesive Bond Strength to Enamel
    Gomes Torres, Carlos Rocha
    Barcellos, Daphne Camara
    Pucci, Cesar Rogerio
    Gouvea Lima, Gabriela de Morais
    Rodrigues, Cristiana Martins
    Siviero, Mariana
    JOURNAL OF ADHESIVE DENTISTRY, 2009, 11 (04) : 279 - 286
  • [14] Influence of de/remineralization of enamel on the tensile bond strength of etch-and-rinse and self-etching adhesives
    Farias de lacerda, Ana Julia
    Zanatta, Rayssa Ferreira
    Crispim, Bruna
    Borges, Alessandra Buhler
    Goivies Torres, Carlos Rocha
    Tay, Franiclin R.
    Pucci, Cesar Rogerio
    AMERICAN JOURNAL OF DENTISTRY, 2016, 29 (05) : 289 - 293
  • [15] Water Content in Self-Etching Primers Affects Their Aggressiveness and Strength of Bonding to Ground Enamel
    Lima, Giana S.
    Ogliari, Fabricio A.
    Moraes, Rafael R.
    Mattos, Elisa S.
    Silva, Adriana F.
    Carreno, Neftali L. V.
    Petzhold, Cesar L.
    Piva, Evandro
    JOURNAL OF ADHESION, 2010, 86 (09) : 937 - 950
  • [16] Adhesion Performance of New Hydrolytically Stable One-component Self-etching Enamel/Dentin Adhesives
    Salz, Ulrich
    Bock, Thorsten
    JOURNAL OF ADHESIVE DENTISTRY, 2010, 12 (01) : 7 - 10
  • [17] Effect of acid-etching on the enamel bond of two self-etching systems
    Miguez, PA
    Castro, PS
    Nunes, MF
    Walter, R
    Pereira, PNR
    JOURNAL OF ADHESIVE DENTISTRY, 2003, 5 (02) : 107 - 112
  • [18] MICROTENSILE BOND STRENGTH OF SELF-ETCHING ADHESIVES TO DENTIN
    Vulicevic, Zoran R.
    Radovic, Ivana
    Cury, Alvaro Hafiz
    Krstanovic, Goranka
    Mandic, Jelena
    Ferrari, Marco
    METALLURGICAL & MATERIALS ENGINEERING, 2008, 14 (02) : 101 - 109
  • [19] Wetting ability of single-component self-etching adhesives on enamel and dentin
    Bortolotto, Tissiana
    Ferrari, Marco
    Krejci, Ivo
    AMERICAN JOURNAL OF DENTISTRY, 2008, 21 (01) : 59 - 63
  • [20] BOND STRENGTH AND MORPHOLOGY OF ENAMEL USING SELF-ETCHING ADHESIVE SYSTEMS WITH DIFFERENT ACIDITIES
    Moura, Sandra Kiss
    Reis, Alessandra
    Pelizzaro, Arlete
    Dal-Bianco, Karen
    Loguercio, Alessandro Dourado
    Arana-Chavez, Victor Elias
    Miranda Grande, Rosa Helena
    JOURNAL OF APPLIED ORAL SCIENCE, 2009, 17 (04) : 315 - 325