The seismic analysis and performance of steel frame with additional low-yield-point steel dampers

被引:13
作者
Akbar, Muhammad [1 ]
Pan Huali [1 ]
Adedamola, Akin-Adewale [2 ]
Ou Guoqiang [1 ]
Amin, Azka [3 ]
机构
[1] Chinese Acad Sci, Inst Mt Hazards & Environm, Chengdu, Peoples R China
[2] Jiangsu Univ Sci & Technol, Sch Civil & Architecture Engn, Zhenjiang, Jiangsu, Peoples R China
[3] Iqra Univ, Karachi, Pakistan
关键词
low-yield-point steel (LYP); steel frame; nonlinear time history analysis; seismic performance; pushover analysis; CONTROLLED SPINE FRAMES;
D O I
10.21595/jve.2020.21531
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes the seismic performance of a steel frame with additional LYP steel dampers. LYP steel dampers provides passive energy dissipation device in a structure, it also reduces the lateral forces in efficient way which is produced by seismic wave. The seismic performance of structures is needed in the design of structure, especially in countries where seismic activities occur. This analysis is accomplished with the FEM and software called SAP2000. The steel frame is only analyzed using numerical simulation. This paper describes two steel frames, the first steel frame is a two story steel frame without LYP steel dampers while the second steel frame has with LYP steel dampers. The seismic mechanism analysis was accomplished with the help of nonlinear time history analysis technique and the results for inter-story drift, steel frames, base shear, the displacement of the top story and the stress of the dampers was obtained. The time history analysis was taken out with three different earthquake waves according to the Chinese code for the seismic design of buildings; the earthquake waves were divided into the three different earthquake levels in China which include the frequent, moderate and rare earthquake level. The seismic mechanism analysis was accomplished on the three different earthquakes and three different earthquake levels in China The modal analysis was taken to obtain the frequency and the period of the steel frames. The steel frames were examined under the different load combination which is also described in the code for the seismic design of buildings to obtain the internal forces of the members of the steel frame which include the axial force, shear force and bending moment. The different load combinations are used to get the stress of the dampers. We notice that the addition of LYP steel dampers increases the seismic resistance of the steel frame as we can observe by a reduction in the displacement of the top story, base shear, and inter-story drift angle by the addition of LYP steel dampers on the steel frame. We can be able to observe the behavior of the frames under the different earthquake levels in China using the pushover analysis.
引用
收藏
页码:647 / 674
页数:28
相关论文
共 41 条
[1]   Shaking table test for evaluating the seismic response characteristics of concentrically braced steel structure with and without hysteretic dampers [J].
Bagheri, Bahador ;
Choi, Kwang-Yong ;
Oh, Sang-Hoon ;
Ryu, Hong-Sik .
INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2016, 16 (01) :23-39
[2]   Heightwise Distribution of Stiffness Ratio for Optimum Seismic Design of Steel Frames with Metallic-Yielding Dampers [J].
Bagheri, Saman ;
Hadidi, Ali ;
Alilou, Alireza .
PROCEEDINGS OF THE TWELFTH EAST ASIA-PACIFIC CONFERENCE ON STRUCTURAL ENGINEERING AND CONSTRUCTION (EASEC12), 2011, 14
[3]  
Bairrao R., 2000, P 12 WORLD C EARTH E
[4]   Shake-table tests of a reinforced concrete frame designed following modern codes: seismic performance and damage evaluation [J].
Benavent-Climent, Amadeo ;
Escolano-Margarit, David ;
Morillas, Leandro .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2014, 43 (06) :791-810
[5]  
Bu G. B., 2012, 15 WORLD C EARTHQ EN
[6]  
Castellano M. G., 2008, AIP C P
[7]  
Chandravanshi M. L., 2013, INT MECH ENG C EXP C
[8]   Simplified design procedure for controlled spine frames with energy-dissipating members [J].
Chen, X. ;
Takeuchi, T. ;
Matsui, R. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 135 :242-252
[9]  
Code for Seismic Design of Buildings, 2010, GB500112010 MIN HOUS
[10]   Assessment of the performance of hysteretic energy dissipation bracing systems [J].
Di Cesare, Antonio ;
Ponzo, Felice Carlo ;
Nigro, Domenico .