The effect of humidity on formaldehyde emission parameters of a medium-density fiberboard: Experimental observations and correlations

被引:45
作者
Liang, Weihui [1 ]
Lv, Mengqiang [2 ]
Yang, Xudong [2 ]
机构
[1] Nanjing Univ, Sch Architecture & Urban Planning, Nanjing 210093, Jiangsu, Peoples R China
[2] Tsinghua Univ, Dept Bldg Sci, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Humidity; Initial emittable concentration; Linear relation; Hydrolysis; Formaldehyde; INITIAL EMITTABLE CONCENTRATION; VOC EMISSIONS; TEMPERATURE; MODEL; EXPOSURE; IMPACT; PARTICLEBOARD; COEFFICIENT; ADSORPTION; IRRITATION;
D O I
10.1016/j.buildenv.2016.03.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Initial emittable concentration (C-0), diffusion coefficient (D-m) and partition coefficient (K) are the three key emission parameters determining formaldehyde emissions from "dry" building materials. Previous studies of humidity effect on formaldehyde emissions were mainly focused on the analysis of steady-state emission rates or concentrations, whereas humidity effects on emission parameters were seldom discussed. In this study, we measured formaldehyde emissions of a medium-density fiberboard in a dynamic small-scale environmental chamber at the relative humidity (RH) of 20%, 30%, 50% and 80%, respectively. Emission parameters were estimated and the effects of humidity were analyzed. C-0 was the most sensitive parameter influenced by humidity, which increased 2.97-fold when RH changed from 20% to 80%. Empirical positive linear relations between C-0 and RH, C-0 and absolute humidity (AH) were identified. Differences of Dm and K between each humidity scenarios were within 11% and 17%, suggesting the negligible impacts of humidity on them. Moreover, the reversible and simultaneous responses of formaldehyde emissions to humidity changes were exhibited in experiments. Possible mechanisms of humidity effect on formaldehyde emission were hydrolysis of resins or polymers and adsorption competitions between formaldehyde and water molecules. The conclusions and empirical relations obtained in this study would be useful in understanding emission parameters at different humidity conditions. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:110 / 115
页数:6
相关论文
共 41 条
  • [1] [Anonymous], 2000, GBT18204262000 ADM Q
  • [2] EnergyPlus and CHAMPS-Multizone co-simulation for energy and indoor air quality analysis
    Chen, Yixing
    Gu, Lixing
    Zhang, Jianshun
    [J]. BUILDING SIMULATION, 2015, 8 (04) : 371 - 380
  • [3] An analytical model for VOCs emission from dry building materials
    Deng, BQ
    Kim, CN
    [J]. ATMOSPHERIC ENVIRONMENT, 2004, 38 (08) : 1173 - 1180
  • [4] Study on a new correlation between diffusion coefficient and temperature in porous building materials
    Deng, Qinqin
    Yang, Xudong
    Zhang, Jianshun
    [J]. ATMOSPHERIC ENVIRONMENT, 2009, 43 (12) : 2080 - 2083
  • [5] Raised exhaled nitric oxide in healthy children is associated with domestic formaldehyde levels
    Franklin, P
    Dingle, P
    Stick, S
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 161 (05) : 1757 - 1759
  • [6] Frihart C. R., 2010, SOC WOOD SCI TECHN P
  • [7] Frihart CR, 2012, FOREST PROD J, V62, P551
  • [8] Influence of mix proportions on microstructure and gas permeability of cement pastes and mortars
    Hamami, A. A.
    Turcry, Ph.
    Ait-Mokhtar, A.
    [J]. CEMENT AND CONCRETE RESEARCH, 2012, 42 (02) : 490 - 498
  • [9] Material emission parameters obtained through regression
    He, G
    Yang, XD
    Shaw, CY
    [J]. INDOOR AND BUILT ENVIRONMENT, 2005, 14 (01) : 59 - 68
  • [10] Sources of formaldehyde, other aldehydes and terpenes in a new manufactured house
    Hodgson, AT
    Beal, D
    McIlvaine, JER
    [J]. INDOOR AIR, 2002, 12 (04) : 235 - 242