Experimental and numerical investigation on suppression of thermal stratification in a water-pool: PIV measurements and CFD simulations

被引:30
作者
Kumar, Sunil [1 ]
Grover, R. B. [1 ]
Yadav, H. [2 ]
Vijayan, P. K. [1 ,3 ]
Kannan, U. [1 ,4 ]
Agrawal, A. [2 ]
机构
[1] Homi Bhabha Natl Inst, Dept Engn Sci, Bombay 400094, Maharashtra, India
[2] Indian Inst Technol, Dept Mech Engn, Bombay 400076, Maharashtra, India
[3] Bhabha Atom Res Ctr, Reactor Engn Div, Bombay 400085, Maharashtra, India
[4] Bhabha Atom Res Ctr, Reactor Phys Design Div, Bombay 400085, Maharashtra, India
关键词
Passive Decay Heat Removal System (PDHRS); Gravity Driven Water Pool (GDWP); Thermal stratification; Shrouds; Particle Image Velocimetry; OpenFOAM; DECAY HEAT REMOVAL; CONTAINMENT COOLING SYSTEM; HOT-WATER; NATURAL-CONVECTION; NUCLEAR-REACTOR; STORAGE TANK; FLOW; CONDENSER; WALL; CHANNEL;
D O I
10.1016/j.applthermaleng.2018.04.070
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper deals with experimental and numerical investigation on thermal stratification phenomenon conducted in a scaled transparent pool using Particle Image Velocimetry (PIV) technique and Computational Fluid Dynamics (CFD) simulations respectively. Experiments were designed to simulate thermal stratification in a pool with an immersed heat exchanger. In general, pools with an immersed heat exchanger tend to get thermally stratified; preventing mixing and participation of the whole pool during the heat removal process. The study presented in the paper, focuses on quantification of thermal stratification in the pool without shrouds and examines the effect of shrouds on suppression of thermal stratification. The installation of three shrouds divides the pool in four compartments and ensures participation of the whole pool inventory in the heat removal process. In all the four compartments, pool water circulation was observed since the beginning of the heat transfer from the heater. In a three-shroud configuration, because of mixing, rate of rise of temperature of water near the top decreases.
引用
收藏
页码:686 / 704
页数:19
相关论文
共 44 条
[1]   THEORETICAL AND EXPERIMENTAL STUDIES OF STRATIFIED THERMOCLINE STORAGE OF HOT WATER [J].
ABDOLY, MA ;
RAPP, D .
ENERGY CONVERSION AND MANAGEMENT, 1982, 22 (03) :275-285
[2]   Heat pipe-based cooling systems for photovoltaic cells under concentrated solar radiation [J].
Akbarzadeh, A ;
Wadowski, T .
APPLIED THERMAL ENGINEERING, 1996, 16 (01) :81-87
[3]  
[Anonymous], 2014, J OPEN RES STW
[4]  
[Anonymous], 2009, IAEATECDOC1624
[5]  
[Anonymous], 2014, FLAPPING FLIGHT BIRD
[6]   A thermal model for photovoltaic panels under varying atmospheric conditions [J].
Armstrong, S. ;
Hurley, W. G. .
APPLIED THERMAL ENGINEERING, 2010, 30 (11-12) :1488-1495
[7]  
Aszodi A., 2000, P 2 INT S 2 PHAS FLO, P1667
[8]   Impact of shape of container on natural convection and melting inside enclosures used for passive cooling of electronic devices [J].
El Omari, Kamal ;
Kousksou, Tarik ;
Le Guer, Yves .
APPLIED THERMAL ENGINEERING, 2011, 31 (14-15) :3022-3035
[9]   Thermal stratification in a hot water tank established by heat loss from the tank [J].
Fan, Jianhua ;
Furbo, Simon .
SOLAR ENERGY, 2012, 86 (11) :3460-3469
[10]   Experimental analysis of a domestic electric hot water storage tank.: Part II:: dynamic mode of operation [J].
Fernandez-Seara, Jose ;
Uhia, Francisco J. ;
Sieres, Jaime .
APPLIED THERMAL ENGINEERING, 2007, 27 (01) :137-144