The X-ray Radiation Response of CdZnTe Crystal Nuclear Detector

被引:0
|
作者
Dai, X. Y. [1 ]
Meng, H. [1 ]
Zhang, Y. L. [1 ]
Tao, J. [1 ]
Xu, R. [1 ]
Zhang, J. J. [1 ]
Huang, J. [1 ]
Wang, L. [1 ]
Tang, K. [1 ]
Min, J. H. [1 ]
Wang, L. J. [1 ]
机构
[1] Shanghai Univ, Sch Mat Sci & Engn, Shanghai 444, Peoples R China
关键词
CdZnTe; radiation response; radiation damage; ELECTROLESS DEPOSITION; SURFACE; PERFORMANCE; CONTACTS; AU;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The X-ray radiation response and radiation damage of CdZnTe (CZT) detector were studied in this paper. After rapid temperature annealing, the linearity of I-V curve was much better than before. Photo current of Au/CZT planar detector increased linearly with the X-ray intensity. An inflection point around 1030 V was observed for different X-ray intensity. Below the inflection points, with the increase of applied voltage, photon current increased linearly, while the current still increased after the inflection point likely due to the illumination-related impact ionization effect. In addition, under exposure in strong X-ray intensity, the photo current remains unchanged before the inflection point while it changes significantly with after the inflection point.
引用
收藏
页码:1296 / 1299
页数:4
相关论文
共 50 条
  • [21] Pulse Shaping System Research of CdZnTe Radiation Detector for High Energy X-ray Diagnostic
    Li Miao
    Zhao Mingkun
    Ding Keyu
    Zhou Shousen
    Zhou Benjie
    FOURTH SEMINAR ON NOVEL OPTOELECTRONIC DETECTION TECHNOLOGY AND APPLICATION, 2018, 10697
  • [22] X-Ray CdZnTe Detector in Transverse and Longitudinal Photoconductivity Mode
    Dikaev, Yu. M.
    Kudryashov, A. A.
    TECHNICAL PHYSICS, 2023, 68 (SUPPL 3) : S415 - S417
  • [23] X-Ray CdZnTe Detector in Transverse and Longitudinal Photoconductivity Mode
    Yu. M. Dikaev
    A. A. Kudryashov
    Technical Physics, 2023, 68 : S415 - S417
  • [24] Hard x-ray response of pixellated CdZnTe detectors
    Abbene, L.
    Del Sordo, S.
    Caroli, E.
    Gerardi, G.
    Raso, G.
    Caccia, S.
    Bertuccio, G.
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (12)
  • [25] CdZnTe detector arrays for low-dose x-ray fluoroscopy
    Heanue, JA
    Pearson, DA
    Melen, RE
    MEDICAL APPLICATIONS OF PENETRATING RADIATION, 1999, 3770 : 114 - 121
  • [26] Performance of a prototype CdZnTe detector module for hard X-ray astrophysics
    Slavis, KR
    Dowkontt, P
    Duttweiler, F
    Epstein, JW
    Hink, PL
    Huszar, GL
    Kalemci, E
    Leblanc, PC
    Matteson, JL
    Pelling, MR
    Rothschild, RE
    Stephan, E
    Tümer, T
    Visser, G
    X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XI, 2000, 4140 : 249 - 256
  • [27] FAST RESPONSE AMPLITUDE SCINTILLATION DETECTOR FOR X-RAY SYNCHROTRON RADIATION
    DEMENTYEV, EN
    SHEROMOV, MA
    SOKOLOV, AS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 549 - 551
  • [28] Detective quantum efficiency of flat panel CdZnTe x-ray detector
    Khym, GL
    Kim, KH
    Park, YJ
    Yang, HJ
    Kim, SU
    Jung, TR
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2004, 45 : S893 - S897
  • [29] Direct measurement of mammographic x-ray spectra using a CdZnTe detector
    Matsumoto, M
    Yamamoto, A
    Honda, I
    Taniguchi, A
    Kanamori, H
    MEDICAL PHYSICS, 2000, 27 (07) : 1490 - 1502
  • [30] CdZnTe x-ray detector for 30 similar to 100 keV energy
    Yoo, SS
    Rodricks, B
    Shastri, SD
    Montano, PA
    HARD X-RAY/GAMMA-RAY AND NEUTRON OPTICS, SENSORS, AND APPLICATIONS, 1996, 2859 : 50 - 56