The X-ray Radiation Response of CdZnTe Crystal Nuclear Detector

被引:0
|
作者
Dai, X. Y. [1 ]
Meng, H. [1 ]
Zhang, Y. L. [1 ]
Tao, J. [1 ]
Xu, R. [1 ]
Zhang, J. J. [1 ]
Huang, J. [1 ]
Wang, L. [1 ]
Tang, K. [1 ]
Min, J. H. [1 ]
Wang, L. J. [1 ]
机构
[1] Shanghai Univ, Sch Mat Sci & Engn, Shanghai 444, Peoples R China
关键词
CdZnTe; radiation response; radiation damage; ELECTROLESS DEPOSITION; SURFACE; PERFORMANCE; CONTACTS; AU;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The X-ray radiation response and radiation damage of CdZnTe (CZT) detector were studied in this paper. After rapid temperature annealing, the linearity of I-V curve was much better than before. Photo current of Au/CZT planar detector increased linearly with the X-ray intensity. An inflection point around 1030 V was observed for different X-ray intensity. Below the inflection points, with the increase of applied voltage, photon current increased linearly, while the current still increased after the inflection point likely due to the illumination-related impact ionization effect. In addition, under exposure in strong X-ray intensity, the photo current remains unchanged before the inflection point while it changes significantly with after the inflection point.
引用
收藏
页码:1296 / 1299
页数:4
相关论文
共 50 条
  • [1] Temporal pulsed x-ray response of CdZnTe: In detector
    Guo, Rong-Rong
    Xu, Ya-Dong
    Zha, Gang-Qiang
    Wang, Tao
    Jie, Wan-Qi
    CHINESE PHYSICS B, 2018, 27 (12)
  • [2] Temporal pulsed x-ray response of CdZnTe:In detector
    郭榕榕
    徐亚东
    查钢强
    王涛
    介万奇
    Chinese Physics B, 2018, 27 (12) : 454 - 458
  • [3] CdZnTe detector as an x-ray spectrometer
    Miyajima, S
    Sakuragi, H
    Matsumoto, M
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 148 - 155
  • [4] CdZnTe and CdTe materials for X-ray and gamma ray radiation detector applications
    Szeles, C
    PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2004, 241 (03): : 783 - 790
  • [5] On the correlation between crystal morphology and X-ray performance of a CdZnTe detector
    Bavdaz, M
    Peacock, A
    Nenonen, S
    Jantunen, MA
    Gagliardi, T
    Tuomi, T
    Hjelt, KT
    Juvonen, M
    Rantamaki, R
    Kraft, S
    Wedowski, M
    Scholze, F
    Ulm, G
    McNally, PJ
    Curley, J
    Danilewsky, AN
    EUX, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VIII, 1997, 3114 : 322 - 332
  • [6] The X-ray response of CdZnTe
    Owens, A
    Bavdaz, M
    Andersson, H
    Gagliardi, T
    Krumrey, M
    Nenonen, S
    Peacock, A
    Taylor, I
    Tröger, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 484 (1-3): : 242 - 250
  • [7] Hard x-ray response of a CdZnTe ring-drift detector
    Owens, A.
    Den Hartog, R.
    Quarati, F.
    Gostilo, V.
    Kondratjev, V.
    Loupilov, A.
    Kozorezov, A.G.
    Wigmore, J.K.
    Webb, A.
    Welter, E.
    Journal of Applied Physics, 2007, 102 (05):
  • [8] Hard x-ray response of a CdZnTe ring-drift detector
    Owens, A.
    den Hartog, R.
    Quarati, F.
    Gostilo, V.
    Kondratjev, V.
    Loupilov, A.
    Kozorezov, A. G.
    Wigmore, J. K.
    Webb, A.
    Welter, E.
    JOURNAL OF APPLIED PHYSICS, 2007, 102 (05)
  • [9] CdZnTe detector in mammographic x-ray spectroscopy
    Miyajima, S
    Imagawa, K
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (22): : 3959 - 3972
  • [10] CdZnTe detector in diagnostic x-ray spectroscopy
    Miyajima, S
    Imagawa, K
    Matsumoto, M
    MEDICAL PHYSICS, 2002, 29 (07) : 1421 - 1429