Experimental study of an ORC (Organic Rankine Cycle) and analysis of R1233zd-E as a drop-in replacement for R245fa for low temperature heat utilization

被引:133
作者
Eyerer, Sebastian [1 ]
Wieland, Christoph [1 ]
Vandersickel, Annelies [1 ]
Spliethoff, Hartmut [1 ,2 ]
机构
[1] Tech Univ Munich, Fac Mech Engn, Inst Energy Syst, Boltzmannstr 15, D-85748 Garching, Germany
[2] Bavarian Ctr Appl Energy Res ZAE Bayern, Div Technol Energy Syst & Renewable Energy 1, Walter Meissner Str, D-85748 Garching, Germany
关键词
Organic Rankine Cycle; ORC; Low GWP working fluid; Low temperature heat utilization; Fourth generation refrigerants; Experimental investigation; POWER-GENERATION; WORKING FLUIDS; WASTE HEAT; RECOVERY; DESIGN;
D O I
10.1016/j.energy.2016.03.034
中图分类号
O414.1 [热力学];
学科分类号
摘要
The Organic Rankine Cycle can be applied to convert low temperature heat to electrical power using organic working fluids. Recently, a new generation of working fluids has been introduced with almost no Ozone Depletion Potential and significantly smaller Global Warming Potential, compared to currently used refrigerants. R1233zd-E is a promising low-GWP (global warming potential) alternative to R245fa, a widely used fluid in ORC (Organic Rankine Cycle) systems. This paper analyzes the applicability of the new fluid as drop-in replacement for R245fa in existing systems and compares system parameters such as cycle efficiency and power output. To this end, the influence of the process parameters mass-flow rate, condensation temperature and expander rotational speed is investigated experimentally for both fluids. The test rig used has an electrical heater as a heat source and a scroll compressor as an expander. As a conclusion, R1233zd-E can be used as a substitute for R245fa in existing ORC systems. In addition to the advantage of having a much smaller GWP, the use of R1233zd-E may lead to higher thermal efficiencies. Comparing the highest achieved thermal efficiency, R1233zd-E performs 6.92% better than R245fa. However, comparing the maximal gross power output, R245fa performs 12.17% better than R1233zd-E. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:660 / 671
页数:12
相关论文
共 32 条
[1]  
American Society of Heating, REFR AIR COND ENG AS
[2]  
[Anonymous], KYOT PROT UN FRAM CO
[3]  
Aumann Richard, 2011, Patent No. [DE 102009053390 B3, 102009053390]
[4]   Experimental tests and modelization of a domestic-scale ORC (Organic Rankine Cycle) [J].
Bracco, Roberto ;
Clemente, Stefano ;
Micheli, Diego ;
Reini, Mauro .
ENERGY, 2013, 58 :107-116
[5]  
Brown JS, 2009, ASHRAE J, V51, P22
[6]  
Datla B. V., 2014, 15 INT COMPR ENG COR
[7]  
Dickes R., 2014, 22 INT COMPR ENG COR
[8]  
Heberle F., 2013, THESIS U BAYREUTH
[9]  
Juhasz J. R., 2015, 3 INT SEM ORC BRUSS
[10]   An experimental and modelling study of a 1 kW organic Rankine cycle unit with mixture working fluid [J].
Jung, Hyung-Chul ;
Taylor, Leighton ;
Krumdieck, Susan .
ENERGY, 2015, 81 :601-614