Monte Carlo simulation to control indoor pollutants from indoor and outdoor sources for residential buildings in Tianjin, China

被引:13
作者
Dai, Xilei [1 ]
Liu, Junjie [1 ]
Zhang, Xin [1 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin Key Lab Indoor Air Environm Qual Control, Tianjin 300072, Peoples R China
关键词
Monte Carlo simulation; PM2.5; Formaldehyde; CO2; Air purifier; AIR-QUALITY; FORMALDEHYDE; PM2.5; EXPOSURE; PARTICLES; RATES; HOMES; PERFORMANCE; ENVIRONMENT; EMISSIONS;
D O I
10.1016/j.buildenv.2019.106376
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The indoor air quality (IAQ) impacts occupants' health significantly. It is important to know the actual IAQ under different source strengths and occupants' air purifier usage strategies. To achieve this goal, we conducted a Monte Carlo simulation to calculate the indoor pollutant concentrations under different conditions. It is confirmed that our simulation is reliable by comparing the simulation results with actual measurement results. According to the simulation results, we found that indoor nighttime CO2, formaldehyde and PM2.5 were lowest in summer. In spring and winter, the nightly indoor CO2 concentration should be kept below 1000 ppm for F3 homes (formaldehyde semission rate: 0.03-0.06 mg/(m(2).h)) and below 900 ppm for F4 homes (formaldehyde emission rate: 0.06-0.12 mg/(m(2).h)) to ensure that the nighttime formaldehyde concentration is lower than 80 mu g/m(3) for one-occupant room. The mean indoor PM2.5 concentration among all sample rooms decreased from 53.2 mu g/ m(3) to 36.8 mu g/m(3) under strategy I (using air purifiers every day) and to 45.8 mu g/m(3) under strategy II (only using when outdoor PM2.5 concentration larger 75 mu g/m(3)). Under the condition of keeping the nighttime CO2 concentration below 1000 ppm, the fraction of healthy days increased from 33.1% to 59.4% and 46.9% for one- and two-occupant rooms under strategy I, respectively. The fraction of unhealthy days decreased from 18.2% to about 7% and 11% under strategy I and strategy II, respectively. Additionally, the suitable clean air change rate was 3-4 h(-1) under current usage time.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Indoor-outdoor relationships of PM2.5 in four residential dwellings in winter in the Yangtze River Delta, China
    Wang, Fang
    Meng, Dan
    Li, Xiuwei
    Tan, Junjie
    ENVIRONMENTAL POLLUTION, 2016, 215 : 280 - 289
  • [32] Source apportionment and health-risk assessment of PM2.5-bound elements in indoor/outdoor residential buildings in Chinese megacities
    Ji, Wenjing
    Zeng, Junjie
    Zhao, Kaijia
    Liu, Jing
    BUILDING AND ENVIRONMENT, 2025, 267
  • [33] Predicted indoor radon concentrations from a Monte Carlo simulation of 1 000 000 granite countertop purchases
    Allen, J. G.
    Zwack, L. M.
    MacIntosh, D. L.
    Minegishi, T.
    Stewart, J. H.
    McCarthy, J. F.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2013, 33 (01) : 151 - 162
  • [34] Dynamics of indoor volatile organic compounds and seasonal ventilation strategies for residential buildings in Northeast China
    Yin, Tingting
    Gao, Weijun
    Wei, Xindong
    Wu, Lei
    Wang, Chao
    INDOOR AND BUILT ENVIRONMENT, 2025, 34 (01) : 227 - 250
  • [35] Relationship between indoor and outdoor temperatures in winter in the Hot Summer and Cold Winter Zone of China - Considering two sources of outdoor temperatures and different indoor heating methods
    Hou, Yuchen
    Zhu, Yingxin
    Cui, Xiuqing
    Wang, Jing
    Jia, Xinyu
    Ab, Bin Cao
    JOURNAL OF BUILDING ENGINEERING, 2024, 87
  • [36] Check updates Indoor air quality analysis of 8 mechanically ventilated residential buildings in northeast China based on long-term monitoring
    Huang, Kailiang
    Sun, Wen
    Feng, Guohui
    Wang, Jun
    Song, Jiasen
    SUSTAINABLE CITIES AND SOCIETY, 2020, 54 (54)
  • [37] Indoor/Outdoor Relationships for Organic and Elemental Carbon in PM2.5 at Residential Homes in Guangzhou, China
    Cao, J. J.
    Huang, H.
    Lee, S. C.
    Chow, Judith C.
    Zou, C. W.
    Ho, K. F.
    Watson, John G.
    AEROSOL AND AIR QUALITY RESEARCH, 2012, 12 (05) : 902 - 910
  • [38] Influence of ambient (outdoor) sources on residential indoor and personal PM2.5 concentrations:: Analyses of RIOPA data
    Meng, QY
    Turpin, BJ
    Korn, L
    Weisel, CP
    Morandi, M
    Colome, S
    Zhang, JFJ
    Stock, T
    Spektor, D
    Winer, A
    Zhang, L
    Lee, JH
    Giovanetti, R
    Cui, W
    Kwon, J
    Alimokhtari, S
    Shendell, D
    Jones, J
    Farrar, C
    Maberti, S
    JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2005, 15 (01): : 17 - 28
  • [39] Influence of ambient (outdoor) sources on residential indoor and personal PM2.5 concentrations: Analyses of RIOPA data
    Qing Yu Meng
    Barbara J Turpin
    Leo Korn
    Clifford P Weisel
    Maria Morandi
    Steven Colome
    Junfeng Zhang
    Thomas Stock
    Dalia Spektor
    Arthur Winer
    Lin Zhang
    Jong Hoon Lee
    Robert Giovanetti
    William Cui
    Jaymin Kwon
    Shahnaz Alimokhtari
    Derek Shendell
    Jennifer Jones
    Corice Farrar
    Silvia Maberti
    Journal of Exposure Science & Environmental Epidemiology, 2005, 15 : 17 - 28
  • [40] A Biplot-Based PCA Approach to Study the Relations between Indoor and Outdoor Air Pollutants Using Case Study Buildings
    Zhang, He
    Srinivasan, Ravi
    BUILDINGS, 2021, 11 (05)