Development of membrane inlet photoionization ion trap mass spectrometer for trace VOCs analysis

被引:22
|
作者
Shi, Wenyan [1 ,2 ]
Huo, Xinming [3 ]
Tian, Yuan [1 ]
Lu, Xinqiong [4 ]
Yang, Lili [5 ]
Zhou, Qian [1 ]
Wang, Xiaohao [1 ,2 ]
Yu, Quan [1 ]
机构
[1] Tsinghua Shenzhen Int Grad Sch, Div Adv Mfg, Shenzhen 518055, Peoples R China
[2] Tsinghua Univ, Dept Precis Instrument, State Key Lab Precis Measurement Technol & Instru, Beijing 100084, Peoples R China
[3] Tsinghua Univ, Tsinghua Shenzhen Int Grad Sch, Div Life Sci & Hlth, Shenzhen 518055, Peoples R China
[4] Shenzhen Chin Instrument Co Ltd, Shenzhen 518055, Peoples R China
[5] Yanshan Univ, Measurement Technol & Instrumentat Key Lab Hebei, Qinhuangdao 066004, Hebei, Peoples R China
基金
中国国家自然科学基金;
关键词
Miniature mass spectrometer; Membrane inlet; Photoionization; VOCs analysis; Pulsed carrier gas; VOLATILE ORGANIC-COMPOUNDS; MINIATURE; IONIZATION; INTERFACE; AIR;
D O I
10.1016/j.talanta.2021.122352
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
With the development of instrumental miniaturization, the portable mass spectrometer is becoming a new tool for on-site rapid analysis of environmental samples. Membrane inlet (MI) and photoionization (PI) are two commonly used sampling and ionization techniques, respectively, as they both exhibit detection selectivity for volatile organic compounds (VOCs). In this paper, a membrane inlet photoionization ion trap mass spectrometer was developed for the direct analysis of VOCs in gaseous samples. With the new structure and timing design, various operation modes were proposed and tested. In particular, the use of pulse carrier gas can integrate the appropriate pressure conditions required by each module, thus improving the efficiency of analyte transport, ionization, and mass analysis. The detection limit of sub-ppb was obtained, and the response time can be greatly reduced by increasing the sample flow rate. Furthermore, the capability of selective enrichment for organic analytes was also realized by using a special accumulation mode with a modified sequence, which is easy to operate because no additional devices are needed.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Trace analysis of BTEX compounds in water with a membrane interfaced ion mobility spectrometer
    Wan, C
    Harrington, PD
    Davis, DM
    TALANTA, 1998, 46 (05) : 1169 - 1179
  • [22] Trap-and-release membrane inlet ion mobility spectrometry for on-line measurement of trace propofol in exhaled air
    Zhou, Qinghua
    Li, Enyou
    Wang, Xin
    Gong, Yulei
    Hua, Lei
    Wang, Weiguo
    Qu, Tuanshuai
    Li, Jinghua
    Liu, Yiping
    Wang, Changsong
    Li, Haiyang
    ANALYTICAL METHODS, 2014, 6 (03) : 698 - 703
  • [23] Ion storage biases in the ion funnel trap of a Hybrid ion mobility spectrometer/time of flight mass spectrometer
    Li, Junhui
    Liu, Rong
    Gao, Wenqing
    Yu, Jiancheng
    Tang, Keqi
    TALANTA, 2023, 260
  • [24] An in-source stretched membrane inlet for on-line analysis of VOCs in water with single photon ionization TOFMS
    Hou, Keyong
    Li, Fanglong
    Chen, Wendong
    Chen, Ping
    Xie, Yuanyuan
    Zhao, Wuduo
    Hua, Lei
    Pei, Kemei
    Li, Haiyang
    ANALYST, 2013, 138 (19) : 5826 - 5831
  • [25] Development of portable single photon ionization time-of-flight mass spectrometer combined with membrane inlet
    Gao, Wei
    Tan, Guobin
    Hong, Yi
    Li, Mei
    Nian, Huiqing
    Guo, Changjuan
    Huang, Zhengxu
    Fu, Zhong
    Dong, Junguo
    Xu, Xin
    Cheng, Ping
    Zhou, Zhen
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2013, 334 : 8 - 12
  • [26] Development of Multi-Membrane Near-Infrared Diode Mass Spectrometer for Field Analysis of Aromatic Hydrocarbons
    Mach, Phillip M.
    Wright, Kenneth C.
    Verbeck, Guido F.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2015, 26 (02) : 281 - 285
  • [27] Comparison of Membrane Inlet and Capillary Introduction Miniature Mass Spectrometry for Liquid Analysis
    Shi, Wenyan
    Lu, Xinqiong
    Zhang, Jinbo
    Zhao, Jianhong
    Yang, Lili
    Yu, Quan
    Wang, Xiaohao
    POLYMERS, 2019, 11 (03)
  • [28] A hand-portable digital linear ion trap mass spectrometer
    Xue, Bing
    Sun, Lulu
    Huang, Zhengxu
    Gao, Wei
    Fan, Rongrong
    Cheng, Ping
    Ding, Li
    Ma, Li
    Zhou, Zhen
    ANALYST, 2016, 141 (19) : 5535 - 5542
  • [29] Planar Multipole Ion Trap/Time-of-Flight Mass Spectrometer
    Lorenz, Ulrich J.
    Rizzo, Thomas R.
    ANALYTICAL CHEMISTRY, 2011, 83 (20) : 7895 - 7901
  • [30] Electronics of an ion trap with integrated time-of-flight mass spectrometer
    Schneider, Christian
    Schowalter, Steven J.
    Yu, Peter
    Hudson, Eric R.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2016, 394 : 1 - 8