New analytical methods are needed to understand and optimize the processes by which tablets are produced. Fette 3090 tablet presses are commonly used in the pharmaceutical industry. A near-infrared (NIR) probe was installed into a Fette 3090 feed frame to understand and monitor the die filling process. The second objective was to analyze in detail the different factors that could affect the prediction of the developed NIR calibration models. Two monitoring positions for NIR spectrometers were evaluated; one at each side of the feed frame. A powder wave behavior caused by the paddle motion was observed inside the feed frame. The study also revealed that NIR spectra can help in the understanding of powder flow inside the feed frame. It was demonstrated that NIR spectra baselines can also be used to determine changes in mass inside the feed frame. The new NIR method showed that the paddle wheel speed has a significant impact in the powder dynamics inside the feed frame. The baselines of the NIR spectra depended on the mass hold-up inside the feed frame and paddle wheel speed. Studies using blends were performed to develop a NIR calibration model based on the feed frame system dynamics to determine acetaminophen drug concentration variability during the die filling process. The study found that variation in the distance from the powder to the probe due to paddle wheel speed has a significant effect on the NIR prediction. This study found that with NIR spectroscopy, blend uniformity can be assessed with high accuracy during the die filling process using the corresponding paddle wheel speed in-line calibration model. NIR was demonstrated to be a good development tool for the in-line monitoring of powder during the die filling process.
引用
收藏
页码:40 / 49
页数:10
相关论文
共 29 条
[1]   On-Line Monitoring of A Granulation Process By NIR Spectroscopy [J].
Alcala, Manel ;
Blanco, Marcelo ;
Bautista, Manel ;
Gonzalez, Josep M. .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2010, 99 (01) :336-345
[2]   Quantitative analysis of film coating in a fluidized bed process by in line NIR spectrometry and multivariate batch calibration [J].
Andersson, M ;
Folestad, S ;
Gottfries, J ;
Johansson, MO ;
Josefson, M ;
Wahlund, KG .
ANALYTICAL CHEMISTRY, 2000, 72 (09) :2099-2108
[3]   Monitoring of a film coating process for tablets using near infrared reflectance spectrometry [J].
Andersson, M ;
Josefson, M ;
Langkilde, FW ;
Wahlund, KG .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (1-2) :27-37
[4]   Near-infrared spectroscopic method for real-time monitoring of pharmaceutical powders during voiding [J].
Barajas, Martha J. ;
Cassiani, Alex Rodriguez ;
Vargas, Wandylis ;
Conde, Carlos ;
Ropero, Jorge ;
Figueroa, Jorge ;
Romanach, Rodolfo J. .
APPLIED SPECTROSCOPY, 2007, 61 (05) :490-496
[5]   Pharmaceutical gel analysis by NIR spectroscopy -: Determination of the active principle and low concentration of preservatives [J].
Blanco, M. ;
Alcala, M. ;
Bautista, M. .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2008, 33 (4-5) :409-414
[6]  
Colon Y., 2014, J PHARM INNOV
[7]   Granular flow and segregation in a four-bladed mixer [J].
Conway, SL ;
Lekhal, A ;
Khinast, JG ;
Glasser, BJ .
CHEMICAL ENGINEERING SCIENCE, 2005, 60 (24) :7091-7107
[8]   In-line monitoring of moisture content in fluid bed dryers using near-IR spectroscopy with consideration of sampling effects on method accuracy [J].
Green, RL ;
Thurau, G ;
Pixley, NC ;
Mateos, A ;
Reed, RA ;
Higgins, JP .
ANALYTICAL CHEMISTRY, 2005, 77 (14) :4515-4522
[9]   In-line monitoring of the drug content of powder mixtures and tablets by near-infrared spectroscopy during the continuous direct compression tableting process [J].
Jarvinen, Kristiina ;
Hoehe, Wolfgang ;
Jarvinen, Maiju ;
Poutiainen, Sami ;
Juuti, Mikko ;
Borchert, Sven .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2013, 48 (4-5) :680-688
[10]  
Jivraj Mira, 2000, Pharmaceutical Science and Technology Today, V3, P58, DOI 10.1016/S1461-5347(99)00237-0