Point-of-Care: Roadmap for Analytical Characterization and Validation of a High-Sensitivity Cardiac Troponin I Assay in Plasma and Whole Blood Matrices

被引:18
作者
Christenson, Robert H. [1 ]
Frenk, Lisa D. S. [2 ]
de Graaf, Henk J. [3 ]
van Domburg, Trees S. Y. [3 ]
Wijnands, Frank P. G. [3 ]
Foolen, Helma W. J. [3 ]
Kemper, Danielle W. M. [3 ]
Bruinen, Anne L. [2 ]
Meijering, Bernadet D. M. [3 ]
Fonville, Judith M. [3 ]
de Theije, Femke K. [3 ]
机构
[1] Univ Maryland, Sch Med, Dept Pathol, Baltimore, MD 21201 USA
[2] VieCuri Med Ctr, Venlo, Netherlands
[3] Siemens Healthineers, Eindhoven, Netherlands
关键词
99TH PERCENTILE;
D O I
10.1093/jalm/jfac028
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: High-sensitivity cardiac troponin (hs-cTn) assays enable more precise use of traditional diagnostic strategies and earlier rule-out/rule-in at 0/1 h or 0/2 h after presentation of acute myocardial infarction (AMI). Availability of hs-cTn measurements at point-of-care (POC) can improve timely management of AMI patients. A roadmap for regulatory and analytical validation is exemplified with studies with the Atellica VTLi hs-cTnI at POC. Methods: High-sensitivity performance was assessed with AACC/IFCC expert recommendations. Clinical Laboratory Standards Institute protocols were used for characterizing limit of blank, limit of detection (LoD), limit of quantitation (LoQ), 10% CV, precision, linearity, and analytic specificity with several reagent lots. Bland-Altman, Passing-Bablok, and hematocrit bias plots compared hs-cTnI measurement in lithium-heparin plasma (PL) and whole blood (WB) matrices. Results: LoB was 0.55 ng/L; LoD and LoQ were 1.24 ng/L and 2.1 ng/Lm for PL and 1.60 ng/L and 3.7 ng/L for WB, respectively. The male 99th percentile is 23 ng/L, and female 99th percentile upper reference limit is 18 ng/L; 10% CVs were 6.7 ng/L for PL and 8.9 ng/L for WB. Also >= 50% of hs-cTnI values for healthy cohorts exceeded the LoD, confirming high-sensitivity performance. Linearity spanned from LoQ to 1250 ng/L. Specificity was >90% for 40 potential interferences; no hook effect was detected. WB and PL correlation was WB = 1.02*plasma + 0.3 ng/L (r = 0.996, n = 152). No hs-cTnI association with hematocrit was detected (R-2 = 0.003). Conclusion: This analytical roadmap showed high-sensitivity performance, good analytic characteristics, and excellent PL and WB agreement for the Atellica VTLi hs-cTnI POC system. Essential clinical performance studies in patients by intended POC users may now commence.
引用
收藏
页码:971 / 988
页数:18
相关论文
共 27 条
  • [1] Amsterdam EA, 2014, J AM COLL CARDIOL, V64, P2713, DOI [10.1016/j.jacc.2014.09.017, 10.1016/j.jacc.2014.10.011, 10.1016/j.jacc.2014.09.016, 10.1161/CIR.0000000000000134]
  • [2] [Anonymous], 2008, DEFINING ESTABLISHIN
  • [3] Determination of sex-specific 99th percentile upper reference limits for a point of care high sensitivity cardiac troponin I assay
    Apple, Fred S.
    Schulz, Karen
    Schmidt, Christian W.
    van Domburg, Trees S. Y.
    Fonville, Judith M.
    de Theije, Femke K.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (09) : 1574 - 1578
  • [4] Early Diagnosis of Myocardial Infarction With Point-of-Care High-Sensitivity Cardiac Troponin I
    Boeddinghaus, Jasper
    Nestelberger, Thomas
    Koechlin, Luca
    Wussler, Desiree
    Lopez-Ayala, Pedro
    Walter, Joan Elias
    Troester, Valentina
    Ratmann, Paul David
    Seidel, Funda
    Zimmermann, Tobias
    Badertscher, Patrick
    Wildi, Karin
    Gimenez, Maria Rubini
    Potlukova, Eliska
    Strebel, Ivo
    Freese, Michael
    Miro, Oscar
    Javier Martin-Sanchez, F.
    Kawecki, Damian
    Keller, Dagmar I.
    Gualandro, Danielle M.
    Christ, Michael
    Twerenbold, Raphael
    Mueller, Christian
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (10) : 1111 - 1124
  • [5] Safety and efficacy of the European Society of Cardiology 0/1-hour algorithm for diagnosis of myocardial infarction: systematic review and meta-analysis
    Chiang, Cho-Han
    Chiang, Cho-Hung
    Lee, Gin Hoong
    Gi, Weng-Tein
    Wu, Yuan-Kun
    Huang, Sih-Shiang
    Yeo, Yee Hui
    Giannitsis, Evangelos
    Lee, Chien-Chang
    [J]. HEART, 2020, 106 (13) : 985 - 991
  • [6] Christenson RH., 2020, 72 AACC ANN SCI M AB, P23
  • [7] Validation of high-sensitivity performance for a United States Food and Drug Administration cleared cardiac troponin I assay
    Christenson, Robert H.
    Mullins, Kristin
    Duh, Show-Hong
    [J]. CLINICAL BIOCHEMISTRY, 2018, 56 : 4 - 10
  • [8] Clinical and Laboratory Standards Institute, 2003, EP06A CLSI
  • [9] Clinical and laboratory standards institute, 2012, EP17A2 CLSI
  • [10] Clinical and Laboratory Standards Institute (CLSI), 2018, MEAS PROC COMP BIAS