Clinical validation of high-resolution image reconstruction algorithms in brain 18F-FDG-PET: effect of incorporating Gaussian filter, point spread function, and time-of-flight

被引:14
作者
Nagaki, Akio [1 ,2 ]
Onoguchi, Masahisa [2 ]
Matsutomo, Norikazu [3 ]
机构
[1] Kanazawa Univ, Kurashiki Cent Hosp, Dept Radiol Technol, Kanazawa, Ishikawa 9200942, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, Dept Hlth Sci, Kanazawa, Ishikawa 9200942, Japan
[3] Kyushu Univ, Grad Sch Med Sci, Dept Hlth Sci, Fukuoka 812, Japan
关键词
brain; F-18-FDG; Gaussian filter; ordered subsets expectation maximization; point spread function; positron emission tomography; reconstruction; time-of-flight; WHOLE-BODY; PET; IMPACT; NOISE;
D O I
10.1097/MNM.0000000000000187
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesAccurate estimation of radiopharmaceutical uptake in the brain is difficult because of count statistics, low spatial resolution, and smoothing filter. The aim of this study was to assess the counting rate performance of PET scanners and the image quality with different combinations of high-resolution image reconstruction algorithms in brain F-18-2-fluorodeoxy-d-glucose (F-18-FDG)-PET.Materials and methodsUsing 23 patient studies, we analyzed the coincidence rates of true and random, random fraction, and the noise equivalent counts per axial length (NECpatient) in brain and liver bed positions. The reconstruction algorithms were combined with baseline ordered subsets expectation maximization, Gaussian filter (GF), point spread function (PSF), and time-of-flight (TOF). The image quality of the brain cortex was quantitatively evaluated with respect to spatial resolution, contrast, and signal-to-noise ratio (SNR).ResultsThe true coincidence rate in the brain was higher by 1.86 times and the random coincidence rate was lower by 0.61 times compared with that in the liver. In the brain, random fraction was lower and NECpatient was higher than that of the liver. Although GF improved the SNR, spatial resolution and contrast were reduced by 12 and 11%, respectively (P<0.01). PSF improved spatial resolution and SNR by 11 and 53%, respectively (P<0.01), and TOF improved SNR by approximate to 23% (P<0.01).ConclusionWe have demonstrated that a high-resolution image reconstruction algorithm for brain F-18-FDG-PET is promising without the use of a GF because of high true coincidence counts and that combined with PSF and TOF is optimal for obtaining a better SNR of the image.
引用
收藏
页码:1224 / 1232
页数:9
相关论文
共 26 条
[1]   Improvement in PET/CT Image Quality with a Combination of Point-Spread Function and Time-of-Flight in Relation to Reconstruction Parameters [J].
Akamatsu, Go ;
Ishikawa, Kaori ;
Mitsumoto, Katsuhiko ;
Taniguchi, Takafumi ;
Ohya, Nobuyoshi ;
Baba, Shingo ;
Abe, Koichiro ;
Sasaki, Masayuki .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (11) :1716-1722
[2]   Application and Evaluation of a Measured Spatially Variant System Model for PET Image Reconstruction [J].
Alessio, Adam M. ;
Stearns, Charles W. ;
Tong, Shan ;
Ross, Steven G. ;
Kohlmyer, Steve ;
Ganin, Alex ;
Kinahan, Paul E. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (03) :938-949
[3]   18F-FDG PET and PET/CT in the Evaluation of Cancer Treatment Response [J].
Ben-Haim, Simona ;
Ell, Peter .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (01) :88-99
[4]   Standards for PET Image Acquisition and Quantitative Data Analysis [J].
Boellaard, Ronald .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 :11S-20S
[5]   Effect of reconstruction algorithms on myocardial blood flow measurement with 13N-ammonia PET [J].
Chen, Grace P. ;
Branch, Kelley R. ;
Alessio, Adam M. ;
Pham, Pam ;
Tabibiazar, Ramin ;
Kinahan, Paul ;
Caldwell, James H. .
JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (08) :1259-1265
[6]   Clinical applications of PET in brain tumors [J].
Chen, Wei .
JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (09) :1468-1481
[7]   Focus on time-of-flight PET: the benefits of improved time resolution [J].
Conti, Maurizio .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (06) :1147-1157
[8]   Recommendations on the use of 18F-FDG PET in oncology [J].
Fletcher, James W. ;
Djulbegovic, Benjamin ;
Soares, Heloisa P. ;
Siegel, Barry A. ;
Lowe, Val J. ;
Lyman, Gary H. ;
Coleman, R. Edward ;
Wahl, Richard ;
Paschold, John Christopher ;
Avrill, Norbert ;
Einhorn, Lawrence H. ;
Suh, W. Warren ;
Samson'O, David ;
Delbekell, Dominique ;
Gorman, Mark ;
Shields, Anthony F. .
JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (03) :480-508
[9]   Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 1.0 [J].
Fukukita, Hiroyoshi ;
Senda, Michio ;
Terauchi, Takashi ;
Suzuki, Kazufumi ;
Daisaki, Hiromitsu ;
Matsumoto, Keiichi ;
Ikari, Yasuhiko ;
Hayashi, Masuo .
ANNALS OF NUCLEAR MEDICINE, 2010, 24 (04) :325-334
[10]   Multimodality Assessment of Brain Tumors and Tumor Recurrence [J].
Heiss, Wolf-Dieter ;
Raab, Peter ;
Lanfermann, Heinrich .
JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (10) :1585-1600