A Fully Integrated Closed-Loop System Based on Mesoporous Microneedles-Iontophoresis for Diabetes Treatment

被引:150
作者
Li, Xiangling [1 ,2 ,3 ]
Huang, Xinshuo [1 ,2 ]
Mo, Jingshan [1 ,2 ]
Wang, Hao [1 ,2 ]
Huang, Qiqi [1 ,2 ]
Yang, Cheng [1 ,2 ]
Zhang, Tao [1 ,2 ,3 ]
Chen, Hui-Jiuan [1 ,2 ]
Hang, Tian [1 ,2 ]
Liu, Fanmao [1 ,2 ]
Jiang, Lelun [3 ]
Wu, Qianni [1 ,2 ,4 ]
Li, Hongbo [1 ,2 ]
Hu, Ning [1 ,2 ]
Xie, Xi [1 ,2 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 1, Sch Elect & Informat Technol, State Key Lab Optoelect Mat & Technol, Guangzhou, Peoples R China
[2] Sun Yat Sen Univ, Guangdong Prov Key Lab Display Mat & Technol, Guangzhou, Peoples R China
[3] Sun Yat Sen Univ, Sch Biomed Engn, Guangzhou, Peoples R China
[4] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, Guangzhou, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
mesoporous microneedles-iontophoresis; minimally invasive; diabetes monitor and therapy; intelligent wearable device; closed-loop system; TRANSDERMAL DELIVERY; INSULIN DELIVERY; GLUCOSE; SENSOR; MANAGEMENT; PATCH; ARRAY;
D O I
10.1002/advs.202100827
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A closed-loop system that can mini-invasively track blood glucose and intelligently treat diabetes is in great demand for modern medicine, yet it remains challenging to realize. Microneedles technologies have recently emerged as powerful tools for transdermal applications with inherent painlessness and biosafety. In this work, for the first time to the authors' knowledge, a fully integrated wearable closed-loop system (IWCS) based on mini-invasive microneedle platform is developed for in situ diabetic sensing and treatment. The IWCS consists of three connected modules: 1) a mesoporous microneedle-reverse iontophoretic glucose sensor; 2) a flexible printed circuit board as integrated and control; and 3) a microneedle-iontophoretic insulin delivery component. As the key component, mesoporous microneedles enable the painless penetration of stratum corneum, implementing subcutaneous substance exchange. The coupling with iontophoresis significantly enhances glucose extraction and insulin delivery and enables electrical control. This IWCS is demonstrated to accurately monitor glucose fluctuations, and responsively deliver insulin to regulate hyperglycemia in diabetic rat model. The painless microneedles and wearable design endows this IWCS as a highly promising platform to improve the therapies of diabetic patients.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Is an Automatic Pump Suspension Feature Safe for Children with Type 1 Diabetes? An Exploratory Analysis with a Closed-Loop System
    Cengiz, Eda
    Swan, Karena L.
    Tamborlane, William V.
    Steil, Garry M.
    Steffen, Amy T.
    Weinzimer, Stuart A.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (04) : 207 - 210
  • [32] A Compact Closed-Loop Optogenetics System Based on Artifact-Free Transparent Graphene Electrodes
    Liu, Xin
    Lu, Yichen
    Iseri, Ege
    Shi, Yuhan
    Kuzum, Duygu
    [J]. FRONTIERS IN NEUROSCIENCE, 2018, 12
  • [33] Smart Construction from Head to Toe: A Closed-Loop Lifecycle Management System Based on IoT
    Xu, Jinying
    Lu, Weisheng
    [J]. CONSTRUCTION RESEARCH CONGRESS 2018: CONSTRUCTION INFORMATION TECHNOLOGY, 2018, : 157 - 168
  • [34] A Digital Closed-Loop Control System for MEMS Resonant Pressure Sensors Based on a Quadrature Phase-Locked Loop
    Zhou, Mengyang
    Xia, Wenliang
    Lu, Yulan
    Xie, Bo
    Chen, Jian
    Wang, Junbo
    Chen, Deyong
    [J]. IEEE SENSORS JOURNAL, 2024, 24 (07) : 10355 - 10363
  • [35] Parents' experiences of using a hybrid closed-loop system (CamAPS FX) to care for a very young child with type 1 diabetes: Qualitative study
    Kimbell, Barbara
    Rankin, David
    Hart, Ruth, I
    Allen, Janet M.
    Boughton, Charlotte K.
    Campbell, Fiona
    Frohlich-Reiterer, Elke
    Hofer, Sabine E.
    Kapellen, Thomas M.
    Rami-Merhar, Birgit
    Schierloh, Ulrike
    Thankamony, Ajay
    Ware, Julia
    Hovorka, Roman
    Lawton, Julia
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 2022, 187
  • [36] Assessment of a Program Based on Digital Tools in Monitoring Type 1 Diabetes Patients Using Closed-Loop Systems
    Amaya Garcia, Maria Jose
    Enciso Izquierdo, Fidel Jesus
    Cordero Vaquero, Ana Alejandra
    Lucas Gamero, Jose Antonio
    Cordero Pearson, Andrea
    Claro Garrido, Blanca
    Pulido Chapado, Eugenia
    Gomez Turegano, Paula
    [J]. ENDOCRINOLOGY RESEARCH AND PRACTICE, 2023, 27 (02): : 48 - 53
  • [37] Assessment of a Program Based on Digital Tools in Monitoring Type 1 Diabetes Patients Using Closed-Loop Systems
    Garcia, Mari Jose Amaya
    Izquierdo, Fidel Jesus Enciso
    Vaquero, Ana Alejandra Cordero
    Gamero, Jose Antonio Lucas
    Pearson, Andrea Cordero
    Garrido, Blanca Claro
    Chapado, Eugenia Pulido
    Turegano, Paula Gomez
    [J]. TURKISH JOURNAL OF ENDOCRINOLOGY AND METABOLISM, 2023, 27 (02) : 48 - 53
  • [38] An integrated System Dynamics model for strategic capacity planning in closed-loop recycling networks: A dynamic analysis for the paper industry
    Georgiadis, Patroklos
    [J]. SIMULATION MODELLING PRACTICE AND THEORY, 2013, 32 : 116 - 137
  • [39] Short-term fully closed-loop insulin delivery using faster insulin aspart compared with standard insulin aspart in type 2 diabetes
    Bally, Lia
    Herzig, David
    Ruan, Yue
    Wilinska, Malgorzata E.
    Semmo, Mariam
    Vogt, Andreas
    Wertli, Maria M.
    Vogt, Bruno
    Stettler, Christoph
    Hovorka, Roman
    [J]. DIABETES OBESITY & METABOLISM, 2019, 21 (12) : 2718 - 2722
  • [40] A qualitative study exploring the expectations of people living with type 1 diabetes regarding prospective use of a hybrid closed-loop system
    Quintal, A.
    Messier, V
    Rabasa-Lhoret, R.
    Racine, E.
    [J]. DIABETIC MEDICINE, 2020, 37 (11) : 1832 - 1840