A single-centre experience of 200 consecutive unselected patients in percutaneous EVAR

被引:11
|
作者
Petronelli, Sergio [1 ]
Zurlo, Maria Teresa [2 ]
Giambersio, Silvia [1 ]
Danieli, Lucia [3 ]
Occhipinti, Mariaelena [3 ]
机构
[1] Ente Ecclesiast Osped Gen Reg F Miulli, Unita Operat Semplice, Dipartimentale Radiol Interventist, Acquaviva Delle Fonti, BA, Italy
[2] Ente Ecclesiast Osped Gen Reg F Miulli, Unita Operat Complessa Chirurg Vasc, Dipartimento Chirurg, Acquaviva Delle Fonti, BA, Italy
[3] Univ Cattolica Sacro Cuore, Policlin A Gemelli, Dipartimento Sci Radiol, Ist Radiol, Rome, RM, Italy
来源
RADIOLOGIA MEDICA | 2014年 / 119卷 / 11期
关键词
Prostar XL; EVAR; Percutaneous access; Endovascular treatment; AORTIC-ANEURYSM REPAIR; VASCULAR-SURGERY DEVICE; ENDOVASCULAR REPAIR; CLOSURE DEVICES; PRECLOSE TECHNIQUE; STENT-GRAFT; ACCESS; COMPLICATIONS; SUTURE; RISK;
D O I
10.1007/s11547-014-0399-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study evaluated the feasibility and safety of percutaneous endovascular aneurysm repair (P-EVAR) in an "unselected" population of patients using Prostar XL closure device, comparing our results with the literature data reported for open EVAR (O-EVAR) and P-EVAR in selected populations. We prospectively enrolled 200 patients with abdominal aortic aneurysms to be treated with the P-EVAR procedure, without any selection criteria. Four hundred percutaneous femoral accesses using the Prostar XL closure device were performed. The early follow-up protocol consisted of a Doppler ultrasound (US) examination. Later evaluations were performed with US and computed tomography. Technical success was achieved in all percutaneous accesses (100 %). Ten early complications related to access site were recorded (10/400; 2.5 %): four pseudoaneurysms and six cases of lower limb ischaemia. Five of ten complications occurred in patients presenting calcification of the common femoral arteries, whereas 4/10 were in patients with "complex" groin anatomy. Eight of ten complications occurred at the access site of the main body of the prosthesis using a sheath size > 20 Fr. Percutaneous endovascular aneurysm repair in "unselected" patients is safe and efficient, with a very low risk of access-related complications, comparable to P-EVAR in selected populations and to the best O-EVAR series.
引用
收藏
页码:835 / 841
页数:7
相关论文
共 50 条
  • [11] Pathology-specific late outcome after endovascular repair of thoracic aorta: a single-centre experience
    Dufour, Clemence
    Gamondes, Delphine
    Mansuy, Adeline
    Robin, Jacques
    Boussel, Loic
    Douek, Philippe
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 48 (06) : 923 - 930
  • [12] Externalized transapical guidewire technique for complex aortic disease: a single-centre experience
    Murakami, Takashi
    Morisaki, Akimasa
    Nishimura, Shinsuke
    Takahashi, Yosuke
    Sakon, Yoshito
    Nakano, Mariko
    Sohgawa, Etsuji
    Fujii, Hiromichi
    Shibata, Toshihiko
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 55 (04) : 639 - 645
  • [13] Management of abdominal aortic aneurysm in nonagenarians: A single-centre experience
    Pasqui, Edoardo
    de Donato, Gianmarco
    Giannace, Giovanni
    Panzano, Claudia
    Setacci, Carlo
    Palasciano, Giancarlo
    VASCULAR, 2021, 29 (01) : 27 - 34
  • [14] Cumulative doses analysis in young trauma patients: a single-centre experience
    Salerno, Sergio
    Marrale, Maurizio
    Geraci, Claudia
    Caruso, Giuseppe
    Lo Re, Giuseppe
    Lo Casto, Antonio
    Midiri, Massimo
    RADIOLOGIA MEDICA, 2016, 121 (02): : 144 - 152
  • [15] First experience with JenaValve™: a single-centre cohort
    Nijenhuis, V. J.
    Swaans, M. J.
    Michiels, V.
    de Kroon, T.
    Heijmen, R. H.
    ten Berg, J. M.
    NETHERLANDS HEART JOURNAL, 2015, 23 (01) : 35 - 41
  • [16] "The Sword in the Stone": radical excision of deep infiltrating endometriosis with bowel shaving-a single-centre experience on 703 consecutive patients
    Marcello, Ceccaroni
    Roberto, Clarizia
    Adele, Mussi Erica
    Katarzyna, Stepniewska Anna
    Paola, De Mitri
    Matteo, Ceccarello
    Giacomo, Ruffo
    Francesco, Bruni
    Lorenzo, Rettore
    Daniela, Surico
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2022, 36 (05): : 3418 - 3431
  • [17] Percutaneous Mitral Repair with the MitraClip System in Patients with Mild-to-Moderate and Severe Heart Failure: A Single-Centre Experience
    Bozdag-Turan, Ilkay
    Paranskaya, Liliya
    Birkemeyer, Ralf
    Turan, R. Goekmen
    Kische, Stephan
    Akin, Ibrahim
    Ortak, Jasmin
    Stoeckicht, Yannik
    Schubert, Jochen
    Westphal, Bernd
    Nienaber, Christoph A.
    Ince, Hueseyin
    CARDIOVASCULAR THERAPEUTICS, 2014, 32 (02) : 66 - 73
  • [18] Safety and Outcomes of Inferior Vena Cava Filter Placement in Oncology Patients: A Single-Centre Experience
    Kurzyna, Pawel
    Banaszkiewicz, Marta
    Florczyk, Michal
    Kepski, Jaroslaw
    Pilka, Michal
    Kedzierski, Piotr
    Manczak, Rafal
    Szwed, Piotr
    Kasperowicz, Krzysztof
    Wrona, Katarzyna
    Doroszewski, Grzegorz
    Torbicki, Adam
    Kurzyna, Marcin
    Szmit, Sebastian
    Darocha, Szymon
    CANCERS, 2024, 16 (08)
  • [19] Complications of percutaneous liver biopsy with Klatskin needles: a 36-year single-centre experience
    Takyar, V.
    Etzion, O.
    Heller, T.
    Kleiner, D. E.
    Rotman, Y.
    Ghany, M. G.
    Fryzek, N.
    Williams, V. H.
    Rivera, E.
    Auh, S.
    Liang, T. J.
    Hoofnagle, J. H.
    Koh, C.
    ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2017, 45 (05) : 744 - 753
  • [20] Results of the Total Evolutive Shoulder System (TESS®): a single-centre study of 56 consecutive patients
    Bakir Kadum
    Nader Mafi
    Sigge Norberg
    Arkan S. Sayed-Noor
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 1623 - 1629