A single-centre experience of 200 consecutive unselected patients in percutaneous EVAR

被引:10
作者
Petronelli, Sergio [1 ]
Zurlo, Maria Teresa [2 ]
Giambersio, Silvia [1 ]
Danieli, Lucia [3 ]
Occhipinti, Mariaelena [3 ]
机构
[1] Ente Ecclesiast Osped Gen Reg F Miulli, Unita Operat Semplice, Dipartimentale Radiol Interventist, Acquaviva Delle Fonti, BA, Italy
[2] Ente Ecclesiast Osped Gen Reg F Miulli, Unita Operat Complessa Chirurg Vasc, Dipartimento Chirurg, Acquaviva Delle Fonti, BA, Italy
[3] Univ Cattolica Sacro Cuore, Policlin A Gemelli, Dipartimento Sci Radiol, Ist Radiol, Rome, RM, Italy
来源
RADIOLOGIA MEDICA | 2014年 / 119卷 / 11期
关键词
Prostar XL; EVAR; Percutaneous access; Endovascular treatment; AORTIC-ANEURYSM REPAIR; VASCULAR-SURGERY DEVICE; ENDOVASCULAR REPAIR; CLOSURE DEVICES; PRECLOSE TECHNIQUE; STENT-GRAFT; ACCESS; COMPLICATIONS; SUTURE; RISK;
D O I
10.1007/s11547-014-0399-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study evaluated the feasibility and safety of percutaneous endovascular aneurysm repair (P-EVAR) in an "unselected" population of patients using Prostar XL closure device, comparing our results with the literature data reported for open EVAR (O-EVAR) and P-EVAR in selected populations. We prospectively enrolled 200 patients with abdominal aortic aneurysms to be treated with the P-EVAR procedure, without any selection criteria. Four hundred percutaneous femoral accesses using the Prostar XL closure device were performed. The early follow-up protocol consisted of a Doppler ultrasound (US) examination. Later evaluations were performed with US and computed tomography. Technical success was achieved in all percutaneous accesses (100 %). Ten early complications related to access site were recorded (10/400; 2.5 %): four pseudoaneurysms and six cases of lower limb ischaemia. Five of ten complications occurred in patients presenting calcification of the common femoral arteries, whereas 4/10 were in patients with "complex" groin anatomy. Eight of ten complications occurred at the access site of the main body of the prosthesis using a sheath size > 20 Fr. Percutaneous endovascular aneurysm repair in "unselected" patients is safe and efficient, with a very low risk of access-related complications, comparable to P-EVAR in selected populations and to the best O-EVAR series.
引用
收藏
页码:835 / 841
页数:7
相关论文
共 35 条
[1]   Ultrasound-Guided Access Improves Rate of Access-Related Complications for Totally Percutaneous Aortic Aneurysm Repair [J].
Arthurs, Zachary M. ;
Starnes, Benjamin W. ;
Sohn, Vance Y. ;
Singh, Niten ;
Andersen, Charles A. .
ANNALS OF VASCULAR SURGERY, 2008, 22 (06) :736-741
[2]   Percutaneous AAA repair:: Is it safe? [J].
Börner, G ;
Ivancev, K ;
Sonesson, B ;
Lindblad, B ;
Griffin, D ;
Malina, M .
JOURNAL OF ENDOVASCULAR THERAPY, 2004, 11 (06) :621-626
[3]   Initial experience with endovascular aneurysm repair: Comparison of early results with outcome of conventional open repair [J].
Brewster, DC ;
Geller, SC ;
Kaufman, JA ;
Cambria, RP ;
Gertler, JP ;
LaMuraglia, GM ;
Atamian, S ;
Abbott, WM .
JOURNAL OF VASCULAR SURGERY, 1998, 27 (06) :992-1003
[4]  
Can A, 2008, ENDOVASCULAR AORTIC, P57
[5]  
Chuter TAM, 2000, J ENDOVASC THER, V7, P1
[6]   Which factors increase the risk of conversion to open surgery following endovascular abdominal aortic aneurysm repair? [J].
Cuypers, PWM ;
Laheij, RJF ;
Buth, J .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 20 (02) :183-189
[7]   Mid-term results after endovascular repair of abdominal aortic aneurysms: A four-year experience [J].
Dalainas, I ;
Nano, G ;
Casana, R ;
Tealdi, DG .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2004, 27 (03) :319-323
[8]  
Dosluogiu HH, 2007, J ENDOVASC THER, V14, P184, DOI 10.1583/1545-1550(2007)14[184:TPEROA]2.0.CO
[9]  
2
[10]   Percutaneous Endovascular Aortic Aneurysm Repair: A Prospective Evaluation of Safety, Efficiency, and Risk Factors [J].
Eisenack, Markus ;
Umscheid, Thomas ;
Tessarek, Joerg ;
Torsello, Giovanni F. ;
Torsello, Giovanni B. .
JOURNAL OF ENDOVASCULAR THERAPY, 2009, 16 (06) :708-713