Reliability analysis of the Manchester Triage System: inter-observer and intra-observer agreement

被引:15
|
作者
de Souza, Cristiane Chaves [1 ]
Machado Chianca, Tania Couto [2 ]
Cordeiro Junior, Welfane [3 ]
Paixao Rausch, Maria do Carmo [3 ,4 ]
Lana Nascimento, Gabriela Fontoura [3 ]
机构
[1] Univ Fed Vicosa, Dept Med & Enfermagem, Vicosa, MG, Brazil
[2] Univ Fed Minas Gerais, Escola Enfermagem, Belo Horizonte, MG, Brazil
[3] Grp Brasileiro Classificacao Risco, Belo Horizonte, MG, Brazil
[4] Grp Brasileiro Classificacao Risco, Epidemiol Hlth Serv, Belo Horizonte, MG, Brazil
来源
关键词
Nursing; Emergency Medical Services; Triage; Nursing Assessment; Reproducibility of Results; Validity of Tests; DECISION-MAKING; EMERGENCY-DEPARTMENT; VALIDITY; NURSES;
D O I
10.1590/1518-8345.2205.3005
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Objective: To analyze the reliability of the Manchester Triage System to determine the priority of patients in emergency services. Method: This is a reliability study with a sample of 361 nurses. The data were collected in three stages and the questionnaires were applied using the electronic software. The agreement was measured by the evaluation of clinical cases. The outcomes evaluated were agreement with the gold standard and intra-observer in the indication of the flowchart, discriminator, and level of risk. Data were submitted to univariate and bivariate analyses. The agreement was measured by the Kappa index. Results: The external and internal reliability of the protocol ranged from moderate to substantial (Kappa: 0.55-0.78). The time of professional experience as a nurse, in emergency services and in the classification of risk were associated with external and internal reliability. The correct choice of the discriminator influenced the correct indication of the risk level (R-2 = 0.77, p < 0.0001) more than the correct choice of the flowchart (R-2 = 0.16, p < 0.0001). Conclusion: The reliability of the Manchester Triage System ranged from moderate to substantial and it was influenced by the clinical experience of the nurse. The protocol is safe for defining clinical priorities using different classification flowcharts.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] INTRA-OBSERVER AND INTER-OBSERVER VARIATION IN DIAGNOSIS OF SACRO-ILIITIS
    VANDERLINDEN, S
    VALKENBURG, HA
    CATS, A
    BRITISH JOURNAL OF RHEUMATOLOGY, 1984, 23 (02): : 147 - 147
  • [32] INTER-OBSERVER AND INTRA-OBSERVER VARIABILITY IN THE INTERPRETATION OF THE DISCRETE CHARACTERS OF THE SKULL
    DESTEFANO, GF
    AUEHAUSER, G
    GUIDOTTI, A
    ROSSI, S
    GUALANDI, PB
    JOURNAL OF HUMAN EVOLUTION, 1983, 12 (08) : 690 - 690
  • [33] Anterior segment ultrasound biomicroscopy image analysis using ImageJ software: Intra-observer repeatability and inter-observer agreement
    Qureshi, Azam
    Chen, Haoxing
    Saeedi, Osamah
    Kaleem, Mona A.
    Stoleru, Gianna
    Margo, Jordan
    Kalarn, Sachin
    Alexander, Janet L.
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (04) : 829 - 837
  • [34] Anterior segment ultrasound biomicroscopy image analysis using ImageJ software: Intra-observer repeatability and inter-observer agreement
    Azam Qureshi
    Haoxing Chen
    Osamah Saeedi
    Mona A. Kaleem
    Gianna Stoleru
    Jordan Margo
    Sachin Kalarn
    Janet L. Alexander
    International Ophthalmology, 2019, 39 : 829 - 837
  • [35] Assessment of inter-observer and intra-observer variability in the measurement of QT dispersion
    Bhullar, HK
    Chia, P
    Ong, K
    Ng, WL
    COMPUTERS IN CARDIOLOGY 1996, 1996, : 297 - 300
  • [36] Assessing the inter-observer and intra-observer reliability of radiographic measurements for size-specific dose estimates
    Alrehily, Faisal A.
    BMC MEDICAL IMAGING, 2024, 24 (01):
  • [37] Intra-observer and inter-observer agreement of the manual examination of the lumbar spine in chronic low-back pain
    Etienne Qvistgaard
    Jens Rasmussen
    Jes Lætgaard
    Steen Hecksher-Sørensen
    Henning Bliddal
    European Spine Journal, 2007, 16 : 277 - 282
  • [38] Intra-observer and inter-observer agreement of the manual examination of the lumbar spine in chronic low-back pain
    Qvistgaard, Etienne
    Rasmussen, Jens
    Laetgaard, Jes
    Hecksher-Sorensen, Steen
    Bliddal, Henning
    EUROPEAN SPINE JOURNAL, 2007, 16 (02) : 277 - 282
  • [39] INTRA-OBSERVER AND INTER-OBSERVER MEASUREMENT ERROR IN CRANIOMETRY - VONTOROK WOULD NOT BE PLEASED
    ZEGURA, SL
    UTERMOHLE, CJ
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1982, 57 (02) : 243 - 243
  • [40] Intra-observer and inter-observer variation in the histopathological assessment of chronic viral hepatitis
    Goldin, RD
    Goldin, JG
    Burt, AD
    Dhillon, PA
    Hubscher, S
    Wyatt, J
    Patel, N
    JOURNAL OF HEPATOLOGY, 1996, 25 (05) : 649 - 654