Evaluation of Shear Bond Strength between Resin Composites and Conventional Glass Ionomer Cement in Class II Restorative Technique-An In Vitro Study

被引:9
作者
Bilgrami, Afreen [1 ]
Maqsood, Afsheen [2 ]
Alam, Mohammad Khursheed [3 ]
Ahmed, Naseer [4 ,5 ]
Mustafa, Mohammed [6 ]
Alqahtani, Ali Robaian [6 ]
Alshehri, Abdullah [6 ]
Alqahtani, Abdullah Ali [6 ]
Alghannam, Shahad [7 ]
机构
[1] Fatimah Jinnah Dent Coll, Dept Dent Mat, Karachi 74900, Pakistan
[2] Bahria Univ, Dept Oral Pathol, Dent Coll, Karachi 74400, Pakistan
[3] Jouf Univ, Dept Prevent Dent, Coll Dent, Sakaka 72345, Saudi Arabia
[4] Univ Sains Malaysia, Sch Dent Sci, Prosthodont Unit, Hlth Campus, Kota Baharu 16150, Kelantan, Malaysia
[5] Altamash Inst Dent Med, Dept Prosthodont, Karachi 75500, Pakistan
[6] Prince Sattam Bin Abdulaziz Univ, Dept Conservat Dent Sci, Coll Dent, Al Kharj 11942, Saudi Arabia
[7] Prince Sattam Bin Abdulaziz Univ, Dept Clin & Patient Affairs, Coll Dent, Al Kharj 11942, Saudi Arabia
关键词
sandwich technique; shear bond strength; glass ionomer cement; microhybrid composites; nanocomposites; MICROLEAKAGE; DENTIN;
D O I
10.3390/ma15124293
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The success of dental restorations depends mainly on the ability to bond to other filling materials and tooth substances, in order to resist the multitude of forces acting on the bond within the oral cavity. Although the shortcomings of composite resins have been significantly reduced over the past three decades, microleakage due to shrinkage under masticatory loads is unavoidable. In order to overcome such problems, two materials laminated with matched properties can be used to achieve optimum results. The sandwich technique is an approach in which dentine is replaced by glass ionomer cement (GIC), and enamel is replaced by composite resin. In the past, numerous materials have been proposed with adequate properties to be used in this manner, but the results are conflicting in terms of bonding to the various forms of GIC, and the appearance of microcracks or gap formation during functional loading. This study aimed to evaluate the shear bond strength (SBS) and mode of failure between the following core materials: composite resins (CR) (Methacrylate Z350 (TM), Ceram X (TM), and Spectrum (TM)) with a base material of glass ionomer cement (GIC, Ketac Molar (TM)). Eight samples were made with the help of polytetrafluoroethylene sheets (TEFLON, Wilmington, DE, USA). Each sheet consisted of holes which were 4 mm in diameter and 2 mm in thickness. The combination of materials was sandwiched. The samples were stored in distilled water and then placed in an incubator for 24 h in order to ensure complete polymerization. The samples were thermocycled for 500 cycles between 5-55 degrees C/ 30 s. Following thermocycling, SBS testing was performed using a universal testing machine. Additionally, scanning electron microscopy (SEM) was performed on representative samples for the bond failure analysis between GIC and the composite resins. The Ceram-X (TM) nanocomposite showed significantly higher bond strength than Methacrylate Z350 (TM) or Spectrum (TM) (p = 0.002). The Methacrylate Z350 (TM) and the Spectrum (TM) composite specimens demonstrated a similar SBS (p = 0.281). The SBS of the Ceram X (TM) to GIC was the highest compared to Methacrylate Z350 (TM) and Spectrum (TM). Therefore Ceram X (TM) may produce a better bond with GIC, and may protect teeth against recurrent caries and failure of the restoration. Methacrylate Z350 (TM) is comparable to Spectrum (TM) CR and can be used as an alternative. A combination of adhesive and mixed failure was observed in Methacrylate Z350 (TM) CR and GIC, while adhesive failure was predominantly found in both Ceram X (TM) and Spectrum (TM) with GIC restorations.
引用
收藏
页数:15
相关论文
共 29 条
[1]   Secondary caries risk of different adhesive strategies and restorative materials in permanent teeth: Systematic review and network meta-analysis [J].
Askar, Haitham ;
Krois, Joachim ;
Goestemeyer, Gerd ;
Schwendicke, Falk .
JOURNAL OF DENTISTRY, 2021, 104
[2]  
Aslam S, 2021, ANN KING EDWARD MED, V27, P355
[3]  
Babar B.Z., 2020, PAK ORAL DENT J, V40, P92
[4]  
BECCI Ana Carolina de Oliveira, 2017, Rev. odontol. UNESP, V46, P214, DOI 10.1590/1807-2577.01717
[5]   Glass ionomer cements compared with composite resin in restoration of noncarious cervical lesions: A systematic review and meta-analysis [J].
Bezerra, Isis Morais ;
Muniz Brito, Arella Cristina ;
de Sousa, Simone Alves ;
Santiago, Bianca Marques ;
Cavalcanti, Yuri Wanderley ;
Dantas de Almeida, Leopoldina de Fatima .
HELIYON, 2020, 6 (05)
[6]   Effect of Saliva Contamination on Microleakage of Open Sandwich Restorations [J].
Celik, Cigdem ;
Bayraktar, Yusuf ;
Ozdemir, Behiye Esra .
ACTA STOMATOLOGICA CROATICA, 2020, 54 (03) :273-282
[7]  
Celik E, 2021, Czas Stomatol, V74, P89, DOI [10.5114/jos.2021.106589, DOI 10.5114/JOS.2021.106589]
[8]  
Pacheco ALD, 2017, BRAZ ORAL RES, V31, DOI [10.1590/1807-3107bor-2017.vol31.0088, 10.1590/1807-3107BOR-2017.vol31.0088]
[9]   Microshear Bond Strength of Nanoparticle-Incorporated Conventional and Resin-Modified Glass Ionomer to Caries-Affected Dentin [J].
Fattah, Zahra ;
Jowkar, Zahra ;
Rezaeian, Safoora .
INTERNATIONAL JOURNAL OF DENTISTRY, 2021, 2021
[10]   Shear bond strength and interfacial analysis of high-viscosity glass ionomer cement bonded to dentin with protocols including silver diammine fluoride [J].
Francois, Philippe ;
Greenwall-Cohen, Joseph ;
Le Goff, Stephane ;
Ruscassier, Nathalie ;
Attal, Jean-Pierre ;
Dursun, Elisabeth .
JOURNAL OF ORAL SCIENCE, 2020, 62 (04) :444-448