Time delay estimation for UHF signals in PD location of transformers

被引:0
|
作者
Yang, L [1 ]
Judd, MD [1 ]
Bennoch, CJ [1 ]
机构
[1] Univ Strathclyde, Inst Energy & Environm, Glasgow, Lanark, Scotland
来源
2004 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA | 2004年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Time delay estimation (TDE) is essential for PD location using the UHF technique. However, noise and effects of multi-path propagation are two main problems affecting the accuracy of the estimate. Comparing two methods, which are based on cumulative energy curve and power curve respectively, a cross correlation based method is employed to achieve the estimation. A high-pass filter is applied to the UHF signal to eliminate operating noises. The phase characteristic of the filter is designed to be linear for making the time delay a constant in terms of frequency. A window in the time domain is selected to reduce the effect of multi-path propagation.
引用
收藏
页码:414 / 417
页数:4
相关论文
共 50 条
  • [1] A statistical method of improving the resolution of time-delay of UHF signals for PD location in transformers
    Tang, ZG
    Li, CR
    Cheng, X
    Wang, W
    Li, J
    2005 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2005, : 401 - 404
  • [2] Positioning of UHF PD Sensors on Power Transformers Based on the Attenuation of UHF Signals
    Beura, Chandra Prakash
    Beltle, Michael
    Tenbohlen, Stefan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (04) : 1520 - 1529
  • [3] Location of PD Sources in Power Transformers by UHF and Acoustic Measurements
    Coenen, Sebastian
    Tenbohlen, Stefan
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (06) : 1934 - 1940
  • [4] Simulating propagation of UHF signals for PD monitoring in transformers using the finite difference time domain technique
    Yang, L
    Judd, MD
    Costa, G
    2004 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2004, : 410 - 413
  • [5] Robust Time Delay Estimation Method for Locating UHF Signals of Partial Discharge in Substation
    Hou, Huijuan
    Sheng, Gehao
    Jiang, Xiuchen
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (03) : 1960 - 1968
  • [6] Time-delay estimation algorithm of partial discharge UHF signals in substation based on bispectrum
    Hou, Huijuan
    Sheng, Gehao
    Miao, Peiqing
    Li, Xiuwei
    Jiang, Xiuchen
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2013, 33 (19): : 208 - 214
  • [7] PD Monitoring of Power Transformers by UHF Sensors
    Tenbohlen, S.
    Beltle, M.
    Siegel, Martin
    2017 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM), VOLS 1 & 2, 2017, : 303 - 306
  • [8] Sensitivity of UHF PD Measurements in Power Transformers
    Coenen, S.
    Tenbohlen, S.
    Markalous, S. M.
    Strehl, T.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2008, 15 (06) : 1553 - 1558
  • [9] Study of time delay of UHF signal arrival in Location Partial Discharge
    Yang Jing-gang
    Li Da-jian
    Li Junhao
    Yuan Peng
    Li Yan-ming
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1088 - 1092
  • [10] Time delay estimation techniques in source location
    Cui, Weiwei
    Cao, Zhigang
    Wei, Jianqiang
    Shuju Caiji Yu Chuli/Journal of Data Acquisition and Processing, 2007, 22 (01): : 90 - 99