Assessment of an Exhaled Breath Test Using High-Pressure Photon Ionization Time-of-Flight Mass Spectrometry to Detect Lung Cancer

被引:37
作者
Meng, Shushi [1 ]
Li, Qingyun [2 ]
Zhou, Zuli [1 ]
Li, Hang [2 ]
Liu, Xianping [1 ]
Pan, Shuli [3 ]
Li, Mingru [4 ]
Wang, Lei [2 ]
Guo, Yanqing [3 ]
Qiu, Mantang [1 ]
Wang, Jun [1 ]
机构
[1] Peking Univ, Peoples Hosp, Dept Thorac Surg, 11 Xizhimen S St, Beijing 100044, Peoples R China
[2] Shenzhen Breatha Biol Technol Co Ltd, Shenzhen, Peoples R China
[3] Aerosp 731 Hosp, Med Examinat Ctr, Beijing, Peoples R China
[4] Aerosp 731 Hosp, Dept Thorac Surg, Beijing, Peoples R China
关键词
LOW-DOSE CT; BIOMARKERS;
D O I
10.1001/jamanetworkopen.2021.3486
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IMPORTANCE Exhaled breath is an attractive option for cancer detection. A sensitive and reliable breath test has the potential to greatly facilitate diagnoses and therapeutic monitoring of lung cancer. OBJECTIVE To investigate whether the breath test is able to detect lung cancer using the highly sensitive high-pressure photon ionization time-of-flight mass spectrometry (HPPI-TOFMS). DESIGN, SETTING, AND PARTICIPANTS This diagnostic study was conducted with a prospective-specimen collection, retrospective-blinded evaluation design. Exhaled breath samples were collected before surgery and detected by HPPI-TOFMS. The detection model was constructed by support vector machine (SVM) algorithm. Patients with pathologically confirmed lung cancer were recruited from Peking University People's Hospital, and healthy adults without pulmonary noncalcified nodules were recruited from Aerospace 731 Hospital. Data analysis was performed from August to October 2020. EXPOSURES Breath testing and SVM algorithm. MAIN OUTCOMES AND MEASURES The detection performance of the breath test was measured by sensitivity, specificity, accuracy, and area under the receiver-operating characteristic curve (AUC). RESULTS Exhaled breath samples were from 139 patients with lung cancer and 289 healthy adults, and all breath samples were collected and tested. Of all participants, 228 (53.27%) were women and the mean (SD) age was 57.0 (11.4) years. After clinical outcomes were ascertained, all participants were randomly assigned into the discovery data set (381 participants) and the blinded validation data set (47 participants). The discovery data set was further broken into a training set (286 participants) and a test set (95 participants) to construct and test the detection model. The detection model reached a mean (SD) of 92.97%(4.64%) for sensitivity, 96.68%(2.21%) for specificity, and 95.51% (1.93%) for accuracy in the test set after 500 iterations. In the blinded validation data set (47 participants), the model revealed a sensitivity of 100%, a specificity of 92.86%, an accuracy of 95.74%, and an AUC of 0.9586. CONCLUSIONS AND RELEVANCE This diagnostic study's results suggest that a breath test with HPPI-TOFMS is feasible and accurate for lung cancer detection, which may be useful for future lung cancer screenings.
引用
收藏
页数:10
相关论文
共 33 条
[11]  
GORDON SM, 1985, CLIN CHEM, V31, P1278
[12]   Accuracy and Methodologic Challenges of Volatile Organic Compound-Based Exhaled Breath Tests for Cancer Diagnosis A Systematic Review and Meta-analysis [J].
Hanna, George B. ;
Boshier, Piers R. ;
Markar, Sheraz R. ;
Romano, Andrea .
JAMA ONCOLOGY, 2019, 5 (01)
[13]  
Henschke CI, 2006, NEW ENGL J MED, V355, P1763, DOI 10.1056/NEJMoa060476
[14]   Exhaled biomarkers in lung cancer [J].
Horvath, I. ;
Lazar, Z. ;
Gyulai, N. ;
Kollai, M. ;
Losonczy, G. .
EUROPEAN RESPIRATORY JOURNAL, 2009, 34 (01) :261-275
[15]  
Jemal A, 2011, CA-CANCER J CLIN, V61, P134, DOI [10.3322/caac.21492, 10.3322/caac.20115, 10.3322/caac.20107]
[16]   Dopant-assisted photoionization positive ion mobility spectrometry coupled with time-resolved purge introduction for online quantitative monitoring of intraoperative end-tidal propofol [J].
Jiang, Dandan ;
Wang, Xin ;
Chen, Chuang ;
Wang, Weiguo ;
Guo, Lei ;
Lv, Yang ;
Li, Enyou ;
Li, Haiyang .
ANALYTICA CHIMICA ACTA, 2018, 1032 :83-90
[17]   Online Monitoring of Intraoperative Exhaled Propofol by Acetone-Assisted Negative Photoionization Ion Mobility Spectrometry Coupled with Time-Resolved Purge Introduction [J].
Jiang, Dandan ;
Li, Enyou ;
Zhou, Qinghua ;
Wang, Xin ;
Li, Hanwei ;
Ju, Bangyu ;
Guo, Lei ;
Liu, Desheng ;
Li, Haiyang .
ANALYTICAL CHEMISTRY, 2018, 90 (08) :5280-5289
[18]   Single photon ionization time-of-flight mass spectrometry with a windowless RF-discharge lamp for high temporal resolution monitoring of the initial stage of methanol-to-olefins reaction [J].
Li, QingYun ;
Hua, Lei ;
Xie, Yuanyuan ;
Jiang, Jichun ;
Li, Hanwei ;
Hou, Keyong ;
Tian, Di ;
Li, HaiYang .
ANALYST, 2019, 144 (04) :1104-1109
[19]   Breath Volatile Organic Compound Profiling of Colorectal Cancer Using Selected Ion Flow-tube Mass Spectrometry [J].
Markar, Sheraz R. ;
Chin, Sung-Tong ;
Romano, Andrea ;
Wiggins, Tom ;
Antonowicz, Stefan ;
Paraskeva, Paraskevas ;
Ziprin, Paul ;
Darzi, Ara ;
Hanna, George B. .
ANNALS OF SURGERY, 2019, 269 (05) :903-910
[20]   A review of exhaled breath: a key role in lung cancer diagnosis [J].
Marzorati, Davide ;
Mainardi, Luca ;
Sedda, Giulia ;
Gasparri, Roberto ;
Spaggiari, Lorenzo ;
Cerveri, Pietro .
JOURNAL OF BREATH RESEARCH, 2019, 13 (03)