All-Solid-State Potentiometric Platforms Modified with a Multi-Walled Carbon Nanotubes for Fluoxetine Determination

被引:6
作者
Abd-Rabboh, Hisham S. M. [1 ,2 ]
Hashem, Heba M. [2 ]
Al Shagri, Layla M. S. [3 ]
Amr, Abdel El-Galil E. [4 ]
Almehizia, Abdulrahman A. [4 ]
Naglah, Ahmed M. [4 ]
Kamel, Ayman H. [2 ,3 ]
机构
[1] King Khalid Univ, Fac Sci, Chem Dept, POB 9004, Abha 61413, Saudi Arabia
[2] Ain Shams Univ, Fac Sci, Dept Chem, Cairo 11566, Egypt
[3] Coll Sci, Chem Dept, Sakhir 32038, Bahrain
[4] King Saud Univ, Coll Pharm, Pharmaceut Chem Dept, Riyadh 11451, Saudi Arabia
关键词
screen printed; potentiometric sensors; multi-walled carbon nanotubes (MWCNTs); fluoxetine; nanomaterials-based sensors; ION-SELECTIVE ELECTRODES; LIQUID-PHASE MICROEXTRACTION; SPECTROPHOTOMETRIC DETERMINATION; QUALITY-CONTROL; WATER SAMPLES; HUMAN PLASMA; WASTE-WATER; HUMAN SERUM; SENSORS; NORFLUOXETINE;
D O I
10.3390/membranes12050446
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Novel cost-effective screen-printed potentiometric platforms for simple, fast, and accurate assessment of Fluoxetine (FLX) were designed and characterized. The potentiometric platforms integrate both the FLX sensor and the reference Ag/AgCl electrode. The sensors were based on the use of 4 '-nitrobenzo-15-crown-5 (ionophore I), dibenzo-18-crown-6 (ionophore II), and 2-hydroxypropyl-beta-cyclodextrin (2-HP-beta-CD) (ionophore III) as neutral carriers within a plasticized PVC matrix. Multiwalled carbon nanotubes (MWCNTs) were used as a lipophilic ion-to-electron transducing material and sodium tetrakis [3,5-bis(trifluoromethyl)phenyl] borate (NaTFPB) was used as an anionic excluder. The presented platforms revealed near-Nernstian potentiometric response with slopes of 56.2 +/- 0.8, 56.3 +/- 1.7 and 64.4 +/- 0.2 mV/decade and detection limits of 5.2 x 10(-6), 4.7 x 10(-6) and 2.0 x 10(-7) M in 10 mM Tris buffer solution, pH 7 for sensors based on ionophore I, II, and III, respectively. All measurements were carried out in 10 mM tris buffer solution at pH 7.0. The interfacial capacitance before and after insertion of the MWCNTs layer was evaluated for the presented sensors using the reverse-current chronopotentiometry. The sensors were introduced for successful determination of FLX drug in different pharmaceutical dosage forms. The results were compared with those obtained by the standard HPLC method. Recovery values were calculated after spiking fixed concentrations of FLX in different serum samples. The presented platforms can be potentially manufacturable at large scales and provide a portable, rapid, disposable, and cost-effective analytical tool for measuring FLX.
引用
收藏
页数:14
相关论文
共 53 条
[1]   Tailor-Made Specific Recognition of Cyromazine Pesticide Integrated in a Potentiometric Strip Cell for Environmental and Food Analysis [J].
Abdalla, Nashwa S. ;
Amr, Abd El-Galil E. ;
El-Tantawy, Aliaa S. M. ;
Al-Omar, Mohamed A. ;
Kamel, Ayman H. ;
Khalifa, Nagy M. .
POLYMERS, 2019, 11 (09)
[2]   Determination of Trihexyphenidyl hydrochloride drug in tablets and urine using a potentiometric carbon paste electrode [J].
Abu Shawish, Hazem M. ;
Elhabiby, Mahmoud ;
Abu Aziz, Hadeel S. ;
Saadeh, Salman M. ;
Tbaza, Ahmad .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 235 :18-26
[3]   A mercury(II) selective sensor based on N,N′-bis(salicylaldehyde)-phenylenediamine as neutral carrier for potentiometric analysis in water samples [J].
Abu-Shawish, Hazem M. .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 167 (1-3) :602-608
[4]  
Al-Shalabi R., 2020, AJAC, V11, P233, DOI [10.4236/ajac.2020.116019, DOI 10.4236/AJAC.2020.116019]
[5]   Graphene/graphite paste electrode incorporated with molecularly imprinted polymer nanoparticles as a novel sensor for differential pulse voltammetry determination of fluoxetine [J].
Alizadeh, Taher ;
Azizi, Sorour .
BIOSENSORS & BIOELECTRONICS, 2016, 81 :198-206
[6]   Determination of fluoxetine in pharmaceutical preparations and biological samples using potentiometric sensors based on polymeric membranes [J].
Arvand, M. ;
Rad, N. Ahmadi .
JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (02) :183-188
[7]   Sensitive spectrophotometric determination of fluoxetine from urine samples using charge transfer complex formation after solid phase extraction by magnetic multiwalled carbon nanotubes [J].
Bigdelifam, Davood ;
Mirzaei, Mohammad ;
Hashemi, Mahdi ;
Amoli-Diva, Mitra ;
Rahmani, Omid ;
Zohrabi, Parvin ;
Taherimaslak, Zohreh ;
Turkjokar, Mohammad .
ANALYTICAL METHODS, 2014, 6 (21) :8633-8639
[8]   Potential stability of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers [J].
Bobacka, J .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4932-4937
[9]   Simultaneous determination of Olanzapine and Fluoxetine in human plasma by LC-MS/MS: Its pharmacokinetic application [J].
Bonde, S. L. ;
Bhadane, R. P. ;
Gaikwad, Avinash ;
Gavali, S. R. ;
Katale, D. U. ;
Narendiran, A. S. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 90 :64-71
[10]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536