Endovascular Treatment of Posterior Circulation Saccular Aneurysms With the p64 Flow Modulation Device: Mid-and Long-Term Results in 54 Aneurysms From a Single Center

被引:13
作者
Hellstern, Victoria [1 ]
Aguilar-Perez, Marta [1 ]
Henkes, Elina [1 ]
Serna-Candel, Carmen [1 ]
Wendl, Christina [2 ]
Baezner, Hansjoerg [3 ]
Ganslandt, Oliver [4 ]
Henkes, Hans [1 ,5 ]
机构
[1] Klinikum Stuttgart, Neuroradiolog Klin Kopf & Neurozentrum, Stuttgart, Germany
[2] Univ Klinikum Regensburg, Inst Rontgendiagnost, Zentrum Neuroradiol, Regensburg, Germany
[3] Klinikum Stuttgart, Neurozentrum, Neurolog Klin, Stuttgart, Germany
[4] Klinikum Stuttgart, Neurozentrum, Neurochirurg Klin, Stuttgart, Germany
[5] Univ Duisburg Essen, Med Fak, Essen, Germany
关键词
p64; posterior circulation aneurysms; flow diversion; unruptured aneurysm; saccular aneurysm; PIPELINE EMBOLIZATION DEVICE; INTRACRANIAL ANEURYSMS; CEREBRAL ANEURYSMS; DIVERSION; DIVERTOR; EXPERIENCE; HEMORRHAGE;
D O I
10.3389/fneur.2021.711863
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Flow diverter (FD) stents have become one of the most common tools for treating intracranial aneurysms; however, their role in treating posterior circulation aneurysms is still discussed with controversy. In this study, we evaluated the safety and effectiveness of p64 FD for the treatment of saccular, unruptured aneurysms in the posterior circulation over a long-term follow-up period in a single center. Methods: From our prospectively maintained database, we retrospectively identified patients who underwent treatment of an intracranial saccular aneurysm arising from the posterior circulation with >= 1 p64 FD implanted or attempted between October 2012 and December 2019. Aneurysms could have been treated with prior or concomitant saccular treatment (e.g., coiling, intra-aneurysmal flow diversion). Aneurysms with parent vessel implants other than p64, fusiform aneurysms, and dissections were excluded. Peri- and postprocedural complications, clinical outcome, and clinical and angiographic follow-up results were evaluated. Results: In total, 54 patients (45 female, 9 male; mean age 55.1 years) with 54 intracranial aneurysms met the inclusion criteria. In 51 cases (94.4%), one p64 was implanted; in 2 cases (3.7 %), two p64s were implanted; in one case, deployment of the p64 was not feasible. Procedural complications occurred in 3.7% and postprocedural complications in 9.3 %, respectively. Hemorrhagic complications occurred in 2/54 patients (3.7%), thereof one fatal parenchymal hemorrhage. Ischemic complications were observed in 5/54 patients (9.3%). Early, mid-term, and long-term angiographic follow-up examinations showed complete or near-complete aneurysm occlusion, defined according to the O'Kelly -Marotta (OKM) scale as OKM C + D in 56, 75.6, and 82.9 %, respectively. Asymptomatic side vessel occlusions occurred in 3.8%, each during the first follow-up. Conclusions: The implantation of a p64 FD is a safe and effective device for endovascular treatment of posterior circulation saccular aneurysms with a high success rate and low morbi-mortality.
引用
收藏
页数:9
相关论文
共 25 条
[1]   The p48 Flow Modulation Device with Hydrophilic Polymer Coating (HPC) for the Treatment of Acutely Ruptured Aneurysms: Early Clinical Experience Using Single Antiplatelet Therapy [J].
Aguilar-Perez, Marta ;
Hellstern, Victoria ;
AlMatter, Muhammad ;
Wendl, Christina ;
Baezner, Hansjoerg ;
Ganslandt, Oliver ;
Henkes, Hans .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2020, 43 (05) :740-748
[2]   Pre-procedure P2Y12 reaction units value predicts perioperative thromboembolic and hemorrhagic complications in patients with cerebral aneurysms treated with the Pipeline Embolization Device [J].
Almandoz, Josser E. Delgado ;
Crandall, Benjamin M. ;
Scholz, Jill M. ;
Fease, Jennifer L. ;
Anderson, Ruth E. ;
Kadkhodayan, Yasha ;
Tubman, David E. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2013, 5 :III3-III10
[3]   Flow Diversion of Posterior Circulation Cerebral Aneurysms: A Single-Institution Series of 59 Cases [J].
Bender, Matthew T. ;
Colby, Geoffrey P. ;
Jiang, Bowen ;
Lin, Li-Mei ;
Campos, Jessica K. ;
Xu, Risheng ;
Westbroek, Erick M. ;
Vo, Chau D. ;
Zarrin, David A. ;
Caplan, Justin M. ;
Huang, Judy ;
Tamargo, Rafael J. ;
Coon, Alexander L. .
NEUROSURGERY, 2019, 84 (01) :206-216
[4]   The p48_HPC antithrombogenic flow diverter: initial human experience using single antiplatelet therapy [J].
Bhogal, Pervinder ;
Bleise, Carlos ;
Chudyk, Jorge ;
Lylyk, Ivan ;
Perez, Nicolas ;
Henkes, Hans ;
Lylyk, Pedro .
JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (01)
[5]   Mid-term and long-term follow-up of intracranial aneurysms treated by the p64 Flow Modulation Device: a multicenter experience [J].
Briganti, Francesco ;
Leone, Giuseppe ;
Ugga, Lorenzo ;
Marseglia, Mariano ;
Macera, Antonio ;
Manto, Andrea ;
Delehaye, Luigi ;
Resta, Maurizio ;
Resta, Mariachiara ;
Burdi, Nicola ;
Nuzzi, Nunzio Paolo ;
Divenuto, Ignazio ;
Caranci, Ferdinando ;
Muto, Mario ;
Solari, Domenico ;
Cappabianca, Paolo ;
Maiuri, Francesco .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2017, 9 (01) :70-76
[6]   Endovascular treatment of cerebral aneurysms using flow-diverter devices: A systematic review [J].
Briganti, Francesco ;
Leone, Giuseppe ;
Marseglia, Mariano ;
Mariniello, Giuseppe ;
Caranci, Ferdinando ;
Brunetti, Arturo ;
Maiuri, Francesco .
NEURORADIOLOGY JOURNAL, 2015, 28 (04) :365-375
[7]   Endovascular Treatment of Intracranial Aneurysms With Flow Diverters A Meta-Analysis [J].
Brinjikji, Waleed ;
Murad, Mohammad H. ;
Lanzino, Giuseppe ;
Cloft, Harry J. ;
Kallmes, David F. .
STROKE, 2013, 44 (02) :442-447
[8]   Treatment of Posterior Circulation Aneurysms With the Pipeline Embolization Device [J].
Chalouhi, Nohra ;
Tjoumakaris, Stavropoula ;
Dumont, Aaron S. ;
Gonzalez, L. Fernando ;
Randazzo, Ciro ;
Starke, Robert M. ;
Rosenwasser, Robert H. ;
Jabbour, Pascal .
NEUROSURGERY, 2013, 72 (06) :883-889
[9]   Delayed Ipsilateral Parenchymal Hemorrhage Following Flow Diversion for the Treatment of Anterior Circulation Aneurysms [J].
Cruz, J. P. ;
Chow, M. ;
O'Kelly, C. ;
Marotta, B. ;
Spears, J. ;
Montanera, W. ;
Fiorella, D. ;
Marotta, T. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (04) :603-608
[10]   Review of current intracranial aneurysm flow diversion technology and clinical use [J].
Dandapat, Sudeepta ;
Mendez-Ruiz, Alan ;
Martinez-Galdamez, Mario ;
Macho, Juan ;
Derakhshani, Shahram ;
Foa Torres, Gustavo ;
Pereira, Vitor M. ;
Arat, Anil ;
Wakhloo, Ajay K. ;
Ortega-Gutierrez, Santiago .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2021, 13 (01) :54-+