Heat transfer rate characteristics of two-phase closed thermosyphon heat exchanger

被引:5
|
作者
Song, Wei [1 ,2 ]
Zheng, Changjin [1 ]
Yang, Jiaming [1 ,3 ]
机构
[1] North China Univ Technol, Sch Civil & Engn, Beijing 100144, Peoples R China
[2] Chinese Acad Sci, Inst Geol & Geophys, Key Lab Shale Gas & Geoengn, Beijing 100029, Peoples R China
[3] Harbin Inst Technol, Sch Architecture, Harbin 150090, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Ground source heat pump; Sandbox test bench; Seepage; Heat transfer rate characteristics; Two-phase closed thermosyphon heat exchangers; PERFORMANCE;
D O I
10.1016/j.renene.2021.05.147
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Two-phase closed thermosyphon heat exchangers (TPCTs) have considerable potential for use in ground source heat pump systems. This paper proposes a new metal-polyethylene TPCT that uses water as the working fluid and is composed of a galvanized steel pipe and a polyethylene pipe. The heat transfer rate characteristics of the metal-polyethylene TPCT were studied using a constant-temperature water bath test bench. The experimental results show that the metal-polyethylene TPCT has the best heat transfer rate when the vacuum degree and filling ratio are 1.00 kPa and 12.5%, respectively. The average heat transfer rate increased as the temperature of the heat source and the flow rate of the cooling water increased. Finally, a sandbox test bench was built, which provided seepage and non-seepage experimental conditions for the metal-polyethylene TPCT. In the sandbox experiment, the heat transfer rate capacity of the metal-polyethylene TPCT was initially studied and compared with that of a single U-tube heat exchanger, and the heat transfer rates were similar. When the evaporation section length was 0.5 m, the heat transfer rates were 34.89 W/m and 111.75 W/m under non-seepage and seepage conditions, respectively. The experimental results show that the metal-polyethylene TPCT is feasible as a new type of ground heat exchanger. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页码:397 / 410
页数:14
相关论文
共 50 条
  • [1] Heat transfer characteristics of a two-phase thermosyphon heat exchanger
    Cieslinski, Janusz T.
    Fiuk, Artur
    APPLIED THERMAL ENGINEERING, 2013, 51 (1-2) : 112 - 118
  • [2] Heat transfer characteristics in a closed two-phase thermosyphon
    1600, Publ by Hemisphere Publ Corp, New York, NY, USA
  • [3] Heat transfer characteristics of a two-phase closed thermosyphon
    Noie, SH
    APPLIED THERMAL ENGINEERING, 2005, 25 (04) : 495 - 506
  • [4] Effects of nanofluids on heat transfer characteristics of a two-phase closed thermosyphon
    Kamyar, A.
    Ong, K. S.
    Saidur, R.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 65 : 610 - 618
  • [5] Heat transfer characteristics of titanium/water two-phase closed thermosyphon
    Qi Baojin
    Zhang Li
    Xu Hong
    Sun Yan
    ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (09) : 2174 - 2179
  • [6] Laboratory investigation of the heat transfer characteristics of a two-phase closed thermosyphon
    Zhang, Mingyi
    Lai, Yuanming
    Dong, Yuanhong
    Jin, Long
    Pei, Wansheng
    Harbor, Jon
    COLD REGIONS SCIENCE AND TECHNOLOGY, 2013, 95 : 67 - 73
  • [7] Convective heat transfer in a closed two-phase thermosyphon
    Al-Ani, M. A.
    THERMOPHYSICAL BASIS OF ENERGY TECHNOLOGIES, 2014, 76
  • [8] Heat transfer rates in a closed two-phase thermosyphon
    Caratteristiche di scambio termico nei termosifoni chiusi bifase
    Andreini, Pierangelo, 1600, (45):
  • [9] Comparative heat transfer characteristics of a flat two-phase closed thermosyphon (FTPCT) and a conventional two-phase closed thermosyphon (CTPCT)
    Amatachaya, P.
    Srimuang, W.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (03) : 293 - 298
  • [10] Heat transfer characteristics in a condenser of closed two-phase thermosyphon: Effect of entrainment on heat transfer deterioration
    Hashimoto, Hiroyuki
    Kaminaga, Fumito
    Heat Transfer - Asian Research, 2002, 31 (03): : 212 - 225