Filler improvement and purification effects of constructed rapid infiltration facility

被引:13
作者
Zhao, Rui-song [1 ]
Li, Jia-ke [1 ]
Guo, Chao [1 ]
Li, Fan [1 ]
Li, Huai-en [1 ]
机构
[1] Xian Univ Technol, State Key Lab Ecohydraul Northwest Arid Reg China, Xian 710048, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Constructed rapid infiltration system; Rainwater runoff; Purification effects; Modifier; Permeability; AMMONIA NITROGEN REMOVAL; WATER; ZEOLITE; RUNOFF;
D O I
10.1007/s11356-019-06462-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Purification effects of constructed rapid infiltration system with two main fillers (coarse sand or medium coarse sand) and different addition proportion (5%, 10%, or 15%) modifiers (sponge iron, blast furnace slag, or zeolite) on rainwater runoff were studied through filter column tests. A set of constructed rapid infiltration system test device was designed, which included 9 rainwater filter columns. The test results showed that the permeability of artificial fillers blended with modifiers could have the promotion with varying degrees. There were differences in the characteristics of the modifiers, so the artificial fillers blended with different modifiers had a significant difference for the purification effects on each pollutant. In view of the overall situations, the pollutant removal effects of artificial fillers with two or more modifiers had a smaller gap, and the reduction effects were good, ranging from 38.95 to 46.25% when the main filler is coarse sand and from 46.29 to 49.46% while main filler is medium coarse sand. It was worth noting that the artificial fillers blended with sponge iron showed a slight harden after prolonged used; however, it had little influence on the permeability and water purification effects.
引用
收藏
页码:33654 / 33669
页数:16
相关论文
共 25 条
[1]   State-of-the-art analysis of the environmental benefits of green roofs [J].
Berardi, Umberto ;
GhaffarianHoseini, AmirHosein ;
GhaffarianHoseini, Ali .
APPLIED ENERGY, 2014, 115 :411-428
[2]  
Cui SP, 2014, KEY ENG MATER, V633, P240
[3]   Green engineering principles promote low-impact development [J].
Davis, AP .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (16) :338A-344A
[4]   Removal characteristics of Cd(II) from acidic aqueous solution by modified steel-making slag [J].
Duan, Jinming ;
Su, Bing .
CHEMICAL ENGINEERING JOURNAL, 2014, 246 :160-167
[5]   Effect of Potassium Chlorate on the Treatment of Domestic Sewage by Achieving Shortcut Nitrification in a Constructed Rapid Infiltration System [J].
Fang, Qinglin ;
Xu, Wenlai ;
Yan, Zhijiao ;
Qian, Lei .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2018, 15 (04)
[6]   Evaluation of permeable pavement responses to urban surface runoff [J].
Kamali, Meysam ;
Delkash, Madjid ;
Tajrishy, Massoud .
JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2017, 187 :43-53
[7]  
Li J.K., 2016, LID TECHNOLOGY URBAN
[8]   Experimental study and simulation of water quality purification of urban surface runoff using non-vegetated bioswales [J].
Li, Jiake ;
Jiang, Chunbo ;
Lei, Tingting ;
Li, Yajiao .
ECOLOGICAL ENGINEERING, 2016, 95 :706-713
[9]  
[李婷 Li Ting], 2016, [工业水处理, Industrial Water Treatment], V36, P85
[10]  
[罗发生 Luo Fasheng], 2011, [水处理技术, Technology of Water Treatment], V37, P100