Ultrasonography of the hip in developmental hip dysplasia

被引:55
作者
Bar-On, E
Meyer, S
Harari, S
Porat, S
机构
[1] Schneider Childrens Med Ctr Israel, Paediat Orthopaed, IL-49202 Petah Tikva, Israel
[2] Alyn Hosp, Rabin Med Ctr, Jerusalem, Israel
[3] Hadassah Med Ctr, Jerusalem, Israel
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1998年 / 80B卷 / 02期
关键词
D O I
10.1302/0301-620X.80B2.8381
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Ultrasonography of the hip was performed sequentially by two different examiners in 75 infants, The ultrasound strips were reviewed twice by three paediatric orthopaedic surgeons and classified by the Graf method, The intraobserver and interobserver agreement between the interpretations was analysed using simple and weighted kappa coefficients calculated for agreement on the Graf classification and for grouping as normal (types 1A to 2A), and abnormal requiring treatment (types 2B to 4). When examining the same ultrasound strip, intraobserver agreement for the Graf classification was substantial (mean kappa 0.61), but interobserver agreement was only moderate (kappa 0.50). For the grouping into normal and abnormal, the mean kappa value for intraobserver agreement was 0.67 and for interobserver agreement 0.57, Because of the significant differences in agreement between normal and abnormal hips, we analysed a subgroup of those with at least one abnormal interpretation, Intraobserver agreement within this subgroup showed moderate reliability (kappa 0.41), but interobserver agreement was only fair (kappa 0.28). Interpretations of two different strips performed sequentially showed significantly lower agreement with an intraobserver kappa value of 0.29 and an interobserver value of 0.28, In the subgroup with at least one abnormal reading, the intraobserver kappa was 0.09 and the interobserver 0.1.
引用
收藏
页码:321 / 324
页数:4
相关论文
共 11 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   ULTRASOUND SCREENING FOR CONGENITAL DYSPLASIA OF THE HIP IN NEWBORNS - ITS VALUE [J].
CASTELEIN, RM ;
SAUTER, AJM .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1988, 8 (06) :666-670
[3]   REAL-TIME ULTRASOUND IN THE DIAGNOSIS OF CONGENITAL DISLOCATION AND DYSPLASIA OF THE HIP [J].
CLARKE, NMP ;
HARCKE, HT ;
MCHUGH, P ;
LEE, MS ;
BORNS, PF ;
MACEWEN, GD .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (03) :406-412
[4]   THE RELIABILITY OF ULTRASONOGRAPHIC ASSESSMENT OF NEONATAL HIPS [J].
DIAS, JJ ;
THOMAS, IH ;
LAMONT, AC ;
MODY, BS ;
THOMPSON, JR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (03) :479-482
[5]   ULTRASOUND SCREENING FOR HIP-DYSPLASIA IN NEONATES [J].
EXNER, GU .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1988, 8 (06) :656-660
[7]  
Graf R, 1987, CONGENITAL DYSPLASIA, P172
[8]  
GRISSOM LE, 1988, J ULTRAS MED, V7, P1
[9]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[10]  
SZOKE N, 1988, J PEDIATR ORTHOPED, V8, P12