Bioprosthetic mitral valve replacement in patients aged 65 years or younger: long-term outcomes with the Carpentier-Edwards PERIMOUNT pericardial valve

被引:34
作者
Bourguignon, Thierry [1 ]
Espitalier, Fabien [1 ]
Pantaleon, Clemence [1 ]
Vermes, Emmanuelle [1 ]
El-Arid, Jean Marc [1 ]
Loardi, Claudia [1 ]
Karam, Elias [1 ]
Candolfi, Pascal [2 ]
Ivanes, Fabrice [3 ]
Aupart, Andmichel [1 ]
机构
[1] Trousseau Univ Hosp, Dept Cardiothorac Surg, Tours, France
[2] Edwards Lifesci, Dept Biostat, Nyon, Switzerland
[3] Trousseau Univ Hosp, Dept Cardiol, Tours, France
关键词
Mitral valve replacement; Bioprosthesis; Deterioration; Long-term outcomes; HANCOCK-II BIOPROSTHESIS; HEART-VALVE; FOLLOW-UP; EXPERIENCE; PORCINE; SURGERY; PROSTHESES; SURVIVAL; POSITION; ADULTS;
D O I
10.1093/ejcts/ezy029
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: Mitral valve replacement using a bioprosthesis remains controversial in young patients because data on long-term outcomes are missing. This study evaluated the long-term results of the PERIMOUNT pericardial mitral bioprosthesis in patients aged 65 years or younger. METHODS: From 1984 to 2010, 148 Carpentier-Edwards PERIMOUNT mitral bioprostheses were implanted in 148 patients aged 65 years or younger. Baseline clinical, perioperative and follow-up data were recorded prospectively. Structural valve deterioration (SVD) was defined by strict echocardiographic assessment. RESULTS: The mean follow-up period was 8.6 +/- 5.5 years, for a total of 1269 valve-years. Operative mortality rate was 2.0%. Fifty-one late deaths occurred (linearized rate 4.0% per valve-year). Actuarial survival rates averaged 70 +/- 4%, 53 +/- 6% and 31 +/- 7% after 10, 15 and 20 years of follow-up, respectively. Actuarial freedom from SVD at 10, 15 and 20 years was 78 +/- 5%, 47 +/- 7% and 19 +/- 7%, respectively. Reoperation was associated with no operative mortality. Actuarial freedom from reoperation due to SVD at 10, 15 and 20 years was 82 +/- 4%, 50 +/- 6% and 25 +/- 8%, respectively. Competing risk analysis demonstrated an actual risk of explantation secondary to SVD at 20 years of 44 +/- 5%. Expected valve durability was 14.2 years for this age group. CONCLUSIONS: In the selected patients aged 65 years or younger undergoing mitral valve replacement with a pericardial bioprosthesis, the expected valve durability was 14.2 years. Reoperation for SVD was associated with a low risk of mortality.
引用
收藏
页码:302 / 309
页数:8
相关论文
共 28 条
[21]   Twenty year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses [J].
Oxenham, H ;
Bloomfield, P ;
Wheatley, DJ ;
Lee, RJ ;
Cunningham, J ;
Prescott, RJ ;
Miller, HC .
HEART, 2003, 89 (07) :715-721
[22]   Bleeding with anticoagulation therapy - Who is at risk, and how best to identify such patients [J].
Palareti, Gualtiero ;
Cosmi, Benilde .
THROMBOSIS AND HAEMOSTASIS, 2009, 102 (02) :268-278
[23]   MITROFLOW PERICARDIAL BIOPROSTHESIS - CLINICAL-PERFORMANCE TO 10 YEARS [J].
POMAR, JL ;
JAMIESON, WRE ;
PELLETIER, LC ;
GEREIN, AN ;
CASTELLA, M ;
BROWNLEE, RT .
ANNALS OF THORACIC SURGERY, 1995, 60 (02) :S305-S310
[24]   Long-term outcomes of valve replacement with modern prostheses in young adults [J].
Ruel, M ;
Kulik, A ;
Lam, BK ;
Rubens, FD ;
Hendry, PJ ;
Masters, RG ;
Bedard, P ;
Mesana, TG .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 27 (03) :425-433
[25]   Very long-term survival implications of heart valve replacement with tissue versus mechanical prostheses in adults <60 years of age [J].
Ruel, Marc ;
Chan, Vincent ;
Bedard, Pierre ;
Kulik, Alexander ;
Ressler, Ladislaus ;
Lam, B. Khanh ;
Rubens, Fraser D. ;
Goldstein, William ;
Hendry, Paul J. ;
Masters, Roy G. ;
Mesana, Thierry G. .
CIRCULATION, 2007, 116 (11) :I294-I300
[26]   Twenty-Five Year Experience With the St. Jude Medical Mechanical Valve Prosthesis [J].
Toole, J. Matthew ;
Stroud, Martha R. ;
Kratz, John M. ;
Crumbley, Arthur J., III ;
Bradley, Scott M. ;
Crawford, Fred A., Jr. ;
Ikonomidis, John S. .
ANNALS OF THORACIC SURGERY, 2010, 89 (05) :1402-1409
[27]   Outcome after redo-mitral valve replacement in adult patients: a 10-year single-centre experience [J].
Vohra, Hunaid A. ;
Whistance, Robert N. ;
Roubelakis, Apostolos ;
Burton, Andrew ;
Barlow, Clifford W. ;
Tsang, Geoffrey M. K. ;
Livesey, Steve A. ;
Ohri, Sunil K. .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2012, 14 (05) :575-579
[28]   Transcatheter Mitral Valve Replacement for Degenerated Bioprosthetic Valves and Failed Annuloplasty Rings [J].
Yoon, Sung-Han ;
Whisenant, Brian K. ;
Bleiziffer, Sabine ;
Delgado, Victoria ;
Schofer, Niklas ;
Eschenbach, Lena ;
Fujita, Buntaro ;
Sharma, Rahul ;
Ancona, Marco ;
Yzeiraj, Ermela ;
Cannata, Stefano ;
Barker, Colin ;
Davies, James E. ;
Frangieh, Antonio H. ;
Deuschl, Florian ;
Podlesnikar, Tomaz ;
Asami, Masahiko ;
Dhoble, Abhijeet ;
Chyou, Anthony ;
Masson, Jean-Bernard ;
Wijeysundera, Harindra C. ;
Blackman, Daniel J. ;
Rampat, Rajiv ;
Taramasso, Maurizio ;
Gutierrez-Ibanes, Enrique ;
Chakravarty, Tarun ;
Attizzani, Guiherme F. ;
Kaneko, Tsuyoshi ;
Wong, S. Chiu ;
Sievert, Horst ;
Nietlispach, Fabian ;
Hildick-Smith, David ;
Nombela-Franco, Luis ;
Conradi, Lenard ;
Hengstenberg, Christian ;
Reardon, Michael J. ;
Kasel, Albert Markus ;
Redwood, Simon ;
Colombo, Antonio ;
Kar, Saibal ;
Maisano, Francesco ;
Windecker, Stephan ;
Pilgrim, Thomas ;
Ensminger, Stephan M. ;
Prendergast, Bernard D. ;
Schofer, Joachim ;
Schaefer, Ulrich ;
Bax, Jeroen J. ;
Latib, Azeem ;
Makkar, Raj R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (09) :1121-1131