Common contact sensitizers in Chandigarh, India - A study of 200 patients with the European standard series

被引:70
作者
Sharma, VK [1 ]
Chakrabarti, A [1 ]
机构
[1] Postgrad Inst Med Educ & Res, Dept Dermatol Venereol & Leoprol, Chandigarh 160012, India
关键词
allergic contact dermatitis; standard series; patch testing; chromate; nickel; sesquiterpene lactone mix; para-phenylenediamine; cobalt; fragrance mix; formaldehyde; colophony; neomycin; mercapto mix; parthenium; compositae; plants;
D O I
10.1111/j.1600-0536.1998.tb05677.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
200 patients (122 male, 78 female) with suspected allergic contact dermatitis were patch tested with the European standard series (ESS) and the results compared with other Asian centres. 131 (65.5%) patients showed 1 or more patch test positives to the ESS. Patch tests were positive to all allergens except primin. Potassium dichromate was the most common allergen (20.5%) followed by nickel sulfate (16.5%), SQL mix (14%), PPD (11.5%), cobalt (8%), fragrance mix (7.5%), formaldehyde (6.5%), colophony (5.5%), neomycin sulfate and mercapto mix (5% each). In women, nickel sulfate was the commonest allergen (30.8%) followed by SQL mix (16.7%) and potassium dichromate (15.4%). In men, potassium dichromate was the commonest sensitizer (23.8%) followed by SQL mix and PPD (12.3% each). Our results are at variance with other centres in Asia. SQL mix was able to detect less than 1/2 (42.2%) of patients allergic to ethanolic dilutions of ether extracts of parthenium. We conclude that the European standard series, with exclusion of primin, is suitable for detection of allergic contact dermatitis in India. However, SQL mix is not a adequate screen for parthenium sensitivity and patch testing with extracts of the plant should be continued, wherever indicated. (C) Munkssgaard, 1998.
引用
收藏
页码:127 / 131
页数:5
相关论文
共 29 条
[1]  
AGRUP G, 1969, ACTA DERMATOLVEN S61, V49, P84
[2]  
AGRUP G, 1969, ACTA DERMATOLVEN S61, V49, P74
[3]  
AGRUP G, 1969, ACTA DERM-VENEREOL, V49, P73
[4]  
CRONIN E, 1980, CONTACT DERMATITIS, P279
[5]   PATCH TESTING WITH THE SESQUITERPENE LACTONE MIX - A MARKER FOR CONTACT ALLERGY TO COMPOSITAE AND OTHER SESQUITERPENE-LACTONE-CONTAINING PLANTS [J].
DUCOMBS, G ;
BENEZRA, C ;
TALAGA, P ;
ANDERSEN, KE ;
BURROWS, D ;
CAMARASA, JG ;
DOOMSGOOSSENS, A ;
FROSCH, PJ ;
LACHAPELLE, JM ;
MENNE, T ;
RYCROFT, RJG ;
WHITE, IR ;
SHAW, S ;
WILKINSON, JD .
CONTACT DERMATITIS, 1990, 22 (05) :249-252
[6]   IS THE EUROPEAN STANDARD SERIES SUITABLE FOR PATCH TESTING IN RIYADB, SAUDI-ARABIA [J].
ELRAB, MOG ;
ALSHEIKH, OA .
CONTACT DERMATITIS, 1995, 33 (05) :310-314
[8]   SESQUITERPENE LACTONE MIX IS NOT AN ADEQUATE SCREEN FOR COMPOSITAE ALLERGY [J].
GREEN, C ;
FERGUSON, J .
CONTACT DERMATITIS, 1994, 31 (03) :151-153
[9]   STANDARD PATCH TEST-RESULTS IN 3,225 CONSECUTIVE DANISH PATIENTS FROM 1973 TO 1977 [J].
HAMMERSHOY, O .
CONTACT DERMATITIS, 1980, 6 (04) :263-268
[10]   NEW HYDROXYISOFLAVANS AS CONTACT SENSITIZERS IN COCUS WOOD BRYA-EBENUS DC (FABACEAE) [J].
HAUSEN, BM ;
BRUHN, G ;
KOENIG, WA .
CONTACT DERMATITIS, 1991, 25 (03) :149-155