Impact of the indexed effective orifice area on mid-term cardiac-related mortality after aortic valve replacement

被引:56
作者
Bleiziffer, Sabine [1 ]
Ali, Ayyaz [2 ]
Hettich, Ina M. [1 ]
Akdere, Deniz [1 ]
Laubender, Ruediger P. [3 ]
Ruzicka, Daniel [1 ]
Boehm, Johannes [1 ]
Lange, Ruediger [1 ]
Eichinger, Walter [1 ]
机构
[1] German Heart Ctr Munich, Cardiovasc Surg Clin, D-80636 Munich, Germany
[2] Stanford Univ, Med Ctr, Stanford, CA 94305 USA
[3] Ludwig Maximilians Univ Munchen, Inst Med Informat Biometry & Epidemiol, Munich, Germany
关键词
PROSTHESIS-PATIENT MISMATCH; LONG-TERM SURVIVAL; VENTRICULAR MASS REGRESSION; CLINICAL IMPACT; COMPETING RISK; SIZE; POSITION; DYSFUNCTION; PREVENTION; MODEL;
D O I
10.1136/hrt.2009.177220
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background There has been ongoing controversy as to whether prosthesis-patient mismatch (PPM, defined as indexed effective orifice area (EOAI) <0.85 m(2)/cm(2)) influences mortality after aortic valve replacement (AVR). In most studies, PPM is anticipated by reference tables based on mean EOAs as opposed to individual assessment. These reference values may not reflect the actual in vivo EOAI and hence, the presence or absence of PPM may be based on false assumptions. Objective To assess the impact of small prosthesis EOA on survival after aortic valve replacement AVR. Methods 645 patients had undergone an AVR between 2000 and 2007 entered the study. All patients underwent transthoracic echocardiography for determination of the actual EOAI within 6 months postoperatively. In order to predict time from surgery to death a proportional hazards model for competing risks (cardiac death vs death from other causes) was used. EOAI was entered as a continuous variable. Results PPM occurred in 40% of the patients. After a median follow-up of 2.35 years, 92.1% of the patients were alive. The final Cox regression model showed a significantly increased risk for cardiac death among patients with a smaller EOAI (HR=0.32, p=0.022). The effect of EOAI on the 2-5 year mortality risk was demonstrated by risk plots. Conclusions In contrast to previous studies these EOAI values were obtained through postoperative echocardiography, substantially improving the accuracy of measurement, and the EOAI was modelled as a continuous variable. There was a significantly improved survival for larger EOAIs following AVR. Strategies to avoid PPM should become paramount during AVR.
引用
收藏
页码:865 / 871
页数:7
相关论文
共 34 条
  • [1] DANGERS OF USING OPTIMAL CUTPOINTS IN THE EVALUATION OF PROGNOSTIC FACTORS
    ALTMAN, DG
    LAUSEN, B
    SAUERBREI, W
    SCHUMACHER, M
    [J]. JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1994, 86 (11) : 829 - 835
  • [2] Prosthesis size and long-term survival after aortic valve replacement
    Blackstone, EH
    Cosgrove, DM
    Jamieson, WRE
    Birkmeyer, NJ
    Lemmer, JH
    Miller, DC
    Butchart, EG
    Rizzoli, G
    Yacoub, M
    Chai, AK
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (03) : 783 - 796
  • [3] Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement
    Blais, C
    Dumesnil, JG
    Baillot, R
    Simard, S
    Doyle, D
    Pibarot, P
    [J]. CIRCULATION, 2003, 108 (08) : 983 - 988
  • [4] Impact of patient-prosthesis mismatch on exercise capacity in patients after bioprosthetic aortic valve replacement
    Bleiziffer, S.
    Eichinger, W. B.
    Hettich, I.
    Ruzicka, D.
    Wottke, M.
    Bauernschmitt, R.
    Lange, R.
    [J]. HEART, 2008, 94 (05) : 637 - 641
  • [5] Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: which is the best method?
    Bleiziffer, Sabine
    Eichinger, Walter B.
    Hettich, Ina
    Guenzinger, Ralf
    Ruzicka, Daniel
    Bauernschmitt, Robert
    Lange, Ruediger
    [J]. HEART, 2007, 93 (05) : 615 - 620
  • [6] ACC/AHA 2006 guidelines for the management of patients with valvular heart disease
    Bonow, Robert O.
    Carabello, Blase A.
    Chatterjee, Kanu
    de Leon, Antonio C., Jr.
    Faxon, David P.
    Freed, Michael D.
    Gaasch, William H.
    Lytle, Bruce Whitney
    Nishimura, Rick A.
    O'Gara, Patrick T.
    O'Rourke, Robert A.
    Otto, Catherine M.
    Shah, Pravin M.
    Shanewise, Jack S.
    Smith, Sidney C., Jr.
    Jacobs, Alice K.
    Adams, Cynthia D.
    Anderson, Jeffrey L.
    Antman, Elliott M.
    Faxon, David P.
    Fuster, Valentin
    Halperin, Jonathan L.
    Hiratzka, Loren F.
    Hunt, Sharon A.
    Lytle, Bruce W.
    Nishimura, Rick
    Page, Richard L.
    Riegel, Barbara
    [J]. CIRCULATION, 2006, 114 (05) : E84 - E231
  • [7] STANDARDIZATION OF M-MODE ECHOCARDIOGRAPHIC LEFT-VENTRICULAR ANATOMIC MEASUREMENTS
    DEVEREUX, RB
    LUTAS, EM
    CASALE, PN
    KLIGFIELD, P
    EISENBERG, RR
    HAMMOND, IW
    MILLER, DH
    REIS, G
    ALDERMAN, MH
    LARAGH, JH
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 4 (06) : 1222 - 1230
  • [8] A formula to estimate the approximate surface area if height and weight be known
    Du Bois, D
    Du Bois, EF
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1916, 17 (06) : 863 - 871
  • [9] A proportional hazards model for the subdistribution of a competing risk
    Fine, JP
    Gray, RJ
    [J]. JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1999, 94 (446) : 496 - 509
  • [10] Prosthesis-patient mismatch is not clinically relevant in aortic valve replacement using the Carpentier-Edwards Perimount valve
    Flameng, Willem
    Meuris, Bart
    Herijgers, Paul
    Herregods, Marie-Christine
    [J]. ANNALS OF THORACIC SURGERY, 2006, 82 (02) : 530 - 536