Value of Computed Tomography-Based Three-Dimensional Pre-operative Planning in Cup Placement in Total Hip Arthroplasty With Dysplastic Acetabulum

被引:19
作者
Wu, Peihui [1 ]
Liu, Qiaoli [1 ]
Fu, Ming [1 ]
Zhang, Zhiqi [1 ]
He, Suiwen [1 ]
Liao, Weiming [1 ]
Kang, Yan [1 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Joint Surg, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
total hip arthroplasty; pre-operative plan; three dimensional; developmental dysplastic hip; DEVELOPMENTAL DYSPLASIA; CONGENITAL DYSPLASIA; CROWE I; REPLACEMENT; ACCURACY; RECONSTRUCTION; SOFTWARE; DISLOCATION; COMPONENT; SOCKET;
D O I
10.1080/08941939.2018.1444828
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objects: To investigate the value of CT-based 3D templating software for pre-operative planning in patients with acetabular dysplasia undergoing total hip arthroplasty (THA) with a minimum follow-up of 2 years. Methods: We performed a retrospective review of a single surgeon?s cohort of patients with Crowe I to III developmental dysplastic hip (49 hips in 41 patients) who underwent cementless primary THA and were available for follow-up at a mean of 2.7 years after THA. We analyzed the accuracy of cup size prediction, the reliability of pre- and post-operative cup orientation and position of reconstructed rotation center using CT-based 3D templating software. Post-operative Harris Hip Score and lower limb discrepancy was obtained at the last follow-up. Results: The sizes of 71% of the cup components (35/49) were estimated exactly, and 100% of the cup size estimates were accurate to within one-cup size. There was good reproducibility of pre- and post-operative position of reconstructed rotation center (correlation coefficient r?=?0.396 for vertical position, p?=?0.005; r?=?0.326 for horizontal position, p?=?0.024). There was no substantial agreement between the planned acetabular orientation and that measured post-operatively (correlation coefficient ?0.174 for inclination and 0.045 for anteversion). There were 44 (90%) excellent or good results according to HHS. Seven patients (14%) reported lower limb discrepancy. Conclusions: Pre-operative CT-based 3D templating made it possible to predict accurate cup size and achieve reproducible cup position in patients with dysplastic acetabulum. The reproducibility of cup orientation could not be demonstrated in this study.
引用
收藏
页码:607 / 613
页数:7
相关论文
共 29 条
  • [1] Accuracy of measuring acetabular cup position after total hip arthroplasty: comparison between a radiographic planning software and three-dimensional computed tomography
    Bayraktar, Vahdettin
    Weber, Markus
    von Kunow, Frederik
    Zeman, Florian
    Craiovan, Benjamin
    Renkawitz, Tobias
    Grifka, Joachim
    Woerner, Michael
    [J]. INTERNATIONAL ORTHOPAEDICS, 2017, 41 (04) : 731 - 738
  • [2] Severity of hip dysplasia and loosening of the socket in cemented total hip replacement - A long-term follow-up
    Chougle, A
    Hemmady, MV
    Hodgkinson, JP
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (01): : 16 - 20
  • [3] Acetabular Considerations During Total Hip Arthroplasty for Hip Dysplasia
    Dapuzzo, Michele R.
    Sierra, Rafael J.
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 2012, 43 (03) : 369 - +
  • [4] Acetabular Retroversion in Developmental Dysplasia of the Hip
    Fujii, Masanori
    Nakashima, Yasuharu
    Yamamoto, Takuaki
    Mawatari, Taro
    Motomura, Goro
    Matsushita, Akinobu
    Matsuda, Shuichi
    Jingushi, Seiya
    Iwamoto, Yukihide
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (04) : 895 - 903
  • [5] Hip Dysplasia in the Young Adult
    Gala, Luca
    Clohisy, John C.
    Beaule, Paul E.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (01) : 63 - 73
  • [6] Effect of Cementless Acetabular Component Orientation, Position, and Containment in Total Hip Arthroplasty for Congenital Hip Disease
    Georgiades, George
    Babis, George C.
    Kourlaba, Georgia
    Hartofilakidis, George
    [J]. JOURNAL OF ARTHROPLASTY, 2010, 25 (07) : 1143 - 1150
  • [7] Total hip arthroplasty for congenital hip disease
    Hartofilakidis, G
    Karachalios, T
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (02) : 242 - 250
  • [8] Value of computed tomography-based three-dimensional surgical preoperative planning software in total hip arthroplasty with developmental dysplasia of the hip
    Inoue, Daisuke
    Kabata, Tamon
    Maeda, Toru
    Kajino, Yoshitomo
    Fujita, Kenji
    Hasegawa, Kazuhiro
    Yamamoto, Takashi
    Tsuchiya, Hiroyuki
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2015, 20 (02) : 340 - 346
  • [9] Independent Evaluation of a Mechanical Hip Socket Navigation Systemin Total Hip Arthroplasty
    Jennings, Jason M.
    Randell, Timmothy R.
    Green, Cynthia L.
    Zheng, Guoyan
    Wellman, Samuel S.
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (03) : 658 - 661
  • [10] Minimum Ten-Year Results of a Porous Acetabular Component for Crowe I to III Hip Dysplasia Using an Elevated Hip Center
    Kaneuji, Ayumi
    Sugimori, Tanzo
    Ichiseki, Toru
    Yamada, Kengo
    Fukui, Kiyokazu
    Matsumoto, Tadami
    [J]. JOURNAL OF ARTHROPLASTY, 2009, 24 (02) : 187 - 194