Water movement in the hybrid layer after different dentin treatments

被引:68
作者
Chersoni, S
Suppa, P
Breschi, L
Ferrari, M
Tay, FR
Pashley, DH
Prati, C
机构
[1] Univ Bologna, Dept Dent Sci, Sch Dent, I-40125 Bologna, Italy
[2] Univ Bologna, Dept Anat Sci, I-40125 Bologna, Italy
[3] Univ Trieste, Dept Dent Sci, Sch Dent, Trieste, Italy
[4] Univ Siena, Policlin Le Scotte, Dept Dent Mat & Restorat Dent, I-53100 Siena, Italy
[5] Univ Hong Kong, Prince Philip Dent Hosp, Dept Restorat Dent, Hong Kong, Hong Kong, Peoples R China
[6] Med Coll Georgia, Sch Dent, Dept Oral Biol & Maxillofacial Pathol, Augusta, GA 30912 USA
关键词
hybrid layer; water sorption; dentin; permeability; water droplets; dentin treatments;
D O I
10.1016/j.dental.2003.11.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to examine the morphology of the hybrid layer (HL) of bonded water-stored specimens after different chemical pre-treatments of dentin. Materials and methods. Twenty-seven recently extracted human molars were selected. Fifty-four dentin disks in middle/deep dentin were obtained with a slow speed saw with a diamond-impregnated disk under water lubrication. Smear layers were created with 180 grit silicon carbide under running water for 1 min. Different pre-treatments of dentin were: Group (1) no treatment; Group (2) 35% H3PO4 etch for 15 s followed by 10% glutaraldehyde for 120 s; Group (3) 37% H3PO4 etch for 15 s followed by 5% NaOCl for 120 s. Three dentin bonding agents (DBAs), Prime and Bond NT (P and B), AdmiraBond (AB), and Clearfil SE Bond (SEB) were applied in association with a resin composite following the manufacturers' directions. Each specimen was then longitudinally sectioned and polished with wet SiC papers (up to #4000 grit). Impressions of the polished dentin were immediately taken with a silicone impression material. Bonded specimens were then stored for 3 or 12 h in deionized water. Further impressions of stored specimens were taken after air-drying of specimens for 10 s. Positive replicas were obtained using a polyether impression material. All the replicas and the original specimens were inspected by SEM. Results. A line of droplets (0.5-4 mum in diameter) was observed along the region of the adhesive-HL junction in all replicas of specimens stored in water, except in group 3, when P and B and AB were used. When SEB was used in each group the droplet were found in all groups except the zone of droplets was thinner. No differences in droplets dimensions were seen between 3 or 12 h water storage, or between the different dentin treatments. Conclusions. The replica procedure used in this study was able to detect water trapped in the adhesive-HL region that was released during the setting of the impression material. The droplets observed in this region support the hypothesis that there can be bidirectional water movement within the adhesive-HL complex. (C) 2003 Published by Elsevier Ltd on behalf of Academy of Dental Materials.
引用
收藏
页码:796 / 803
页数:8
相关论文
共 36 条
  • [1] Mechanical and thermal properties of gelatin films at different degrees of glutaraldehyde crosslinking
    Bigi, A
    Cojazzi, G
    Panzavolta, S
    Rubini, K
    Roveri, N
    [J]. BIOMATERIALS, 2001, 22 (08) : 763 - 768
  • [2] Dentin proteoglycans: An immunocytochemical FEISEM study
    Breschi, L
    Lopes, M
    Gobbi, P
    Mazzotti, G
    Falconi, M
    Perdigao, J
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 61 (01): : 40 - 46
  • [3] Burrow MF, 1999, AM J DENT, V12, P295
  • [4] Silver tree
    Fan, ZH
    Yoshimura, N
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1996, 3 (01) : 131 - 135
  • [5] Ferracane JL, 1998, AM J DENT, V11, P23
  • [6] Marginal seal and biocompatibility of a fourth-generation bonding agent
    Goracci, G
    Mori, G
    Bazzucchi, M
    [J]. DENTAL MATERIALS, 1995, 11 (5-6) : 343 - 347
  • [7] In vivo degradation of resin-dentin bonds in humans over 1 to 3 years
    Hashimoto, M
    Ohno, H
    Kaga, M
    Endo, K
    Sano, H
    Oguchi, H
    [J]. JOURNAL OF DENTAL RESEARCH, 2000, 79 (06) : 1385 - 1391
  • [8] Itthagarun A, 2000, AM J DENT, V13, P195
  • [9] EFFECT OF COLLAGEN CROSSLINKING ON COLLAGEN-WATER INTERACTIONS (A DSC INVESTIGATION)
    KOPP, J
    BONNET, M
    RENOU, JP
    [J]. MATRIX, 1990, 9 (06): : 443 - 450
  • [10] Nanoleakage patterns of four dentin bonding systems
    Li, H
    Burrow, MF
    Tyas, MJ
    [J]. DENTAL MATERIALS, 2000, 16 (01) : 48 - 56