Clothing Pressure Modeling Using the Modified Laplace's Law

被引:16
作者
Barhoumi, H. [1 ]
Marzougui, S. [2 ]
Ben Abdessalem, S. [1 ]
机构
[1] Univ Monastir, Text Mat & Proc Res Unit, Monastir 5000, Tunisia
[2] Univ Monastir, Lab Text Engn, Monastir, Tunisia
关键词
clothing pressure; young modulus; flexiforce sensor; knitted garment; strain; INTERFACE PRESSURE; COMPRESSION; THICKNESS; BEHAVIOR;
D O I
10.1177/0887302X19880270
中图分类号
F [经济];
学科分类号
02 ;
摘要
Today, various kinds of pressure garments are designed for specific applications in medical and sports fields. Knitted garments are the most used in these applications due to their high extensibility. The objective of the investigation reported in this article was to develop a theoretical relationship based on Laplace's law, which describes the compression behavior of knitted compression samples in quasi-static deformation from an initially relaxed state to an extended state. Even though several researchers have used Laplace's law, there is some discord between theoretical and experimental results. So, it is essential to pinpoint the most important parameters that influence the mechanical properties of the compression knitted garment in order to better describe the interface pressure it applies to the human body. Fabric parameters that influenced the interface pressure, such as elasticity modulus, strain, and thickness, were determined and integrated into Laplace's law.
引用
收藏
页码:134 / 147
页数:14
相关论文
共 43 条
[1]   Investigating the Accuracy of Prediction Pressure by Laplace Law in Pressure-Garment Applications [J].
Aghajani, Marzie ;
Jeddi, Ali A. A. ;
Tehran, M. Amani .
JOURNAL OF APPLIED POLYMER SCIENCE, 2011, 121 (05) :2699-2704
[2]  
Al Khaburi J., 2011, INT C MECH AUT ICMA
[3]   Effect of bandage thickness on interface pressure applied by compression bandages [J].
Al Khaburi, Jawad ;
Dehghani-Sanij, Abbas A. ;
Nelson, E. Andrea ;
Hutchinson, Jerry .
MEDICAL ENGINEERING & PHYSICS, 2012, 34 (03) :378-385
[4]   Statistics notes - Standard deviations and standard errors [J].
Altman, DG ;
Bland, JM .
BRITISH MEDICAL JOURNAL, 2005, 331 (7521) :903-903
[5]   Measuring contact area, force, and pressure for bioengineering applications: Using Fuji Film and TekScan systems [J].
Bachus, Kent N. ;
DeMarco, Alyssa L. ;
Judd, Kyle T. ;
Horwitz, Daniel S. ;
Brodke, Darrel S. .
MEDICAL ENGINEERING & PHYSICS, 2006, 28 (05) :483-488
[6]  
Barhoumi H, 2018, INDIAN J FIBRE TEXT, V43, P426
[7]  
Barhoumi H., 2018, IEEE 4 MIDDL E C BIO, DOI 10.1109/MECBME.2018.8402418
[8]   Experiments and modelling of skin-knitted fabric friction [J].
Baussan, E. ;
Bueno, M. -A. ;
Rossi, R. M. ;
Derler, S. .
WEAR, 2010, 268 (9-10) :1103-1110
[9]   Influence of linear density of elastic inlay yarn on pressure generation on human body [J].
Bera, Moumita ;
Chattopadhyay, R. ;
Gupta, Deepti .
JOURNAL OF INDUSTRIAL TEXTILES, 2016, 46 (04) :1053-1066
[10]  
Buis A. W., 1979, PROSTHET ORTHOT INT, V21, P179