Coordinated control of rotor and grid sides converters in DFIG based wind turbines for providing optimal reactive power support and voltage regulation

被引:27
作者
Rahimi, Mohsen [1 ]
机构
[1] Univ Kashan, Dept Elect & Comp Engn, Kashan, Iran
关键词
DFIG-based wind turbine; Reactive power control; Optimal reactive power sharing; Rotor-side converter; Grid-side converter; Voltage fluctuations; PERFORMANCE;
D O I
10.1016/j.seta.2017.02.012
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper deals with the coordinated control of the rotor and grid sides converters in DFIG based wind turbines in an optimal manner for providing grid voltage support. By using the proposed coordinated control approach, the required reactive power injected by the DFIG into the grid is optimally shared between the rotor side converter (RSC) and grid side converter (GSC) to minimize the back-to-back converter apparent power. Then the paper examines the capability of the proposed control approaches for improvement of voltage profile, mitigation of voltage rise and reduction of voltage variations at the system under study. In this way, the paper analytically determines the required reactive power that should be optimally injected to the grid by the RSC and GSC, at the stationary and dynamic control modes. Hence, the DFIG can operate in both stationary and dynamic voltage control modes. In the stationary mode, the DFIG exchanges mean reactive power with the grid and improves the voltage profile, and in the dynamic mode, the DFIG exchanges dynamic reactive power and alleviates voltage fluctuations. At the end, simulation results for the system under study are given. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:47 / 57
页数:11
相关论文
共 20 条
[1]  
Aghatehrani R, 2009, IEEE POW ENER SOC GE, P5251
[2]   Impact of Distributed Wind Generators Reactive Power Behavior on Flicker Severity [J].
Ammar, Moataz ;
Joos, Geza .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2013, 28 (02) :425-433
[3]   Co-ordinated voltage control strategy for a doubly-fed induction generator (DFIG)-based wind farm [J].
Cartwright, P ;
Holdsworth, L ;
Ekanayake, JB ;
Jenkins, N .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2004, 151 (04) :495-502
[4]   Coordinated reactive power control for facilitating fault ride through of doubly fed induction generator- and fixed speed induction generator-based wind farms [J].
Foster, S. ;
Xu, L. ;
Fox, B. .
IET RENEWABLE POWER GENERATION, 2010, 4 (02) :128-138
[5]   Coordinated control and operation of DFIG and FSIG based Wind Farms [J].
Foster, Sarah ;
Xu, Lie ;
Fox, Brendan .
2007 IEEE LAUSANNE POWERTECH, VOLS 1-5, 2007, :522-527
[6]   Reactive power control strategies for DFIG-based plants [J].
Kayikci, Mustafa ;
Milanovic, Jovica V. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (02) :389-396
[7]   Benefits of Power Electronic Interfaces for Distributed Energy Systems [J].
Kroposki, Benjamin ;
Pink, Christopher ;
DeBlasio, Richard ;
Thomas, Holly ;
Simoes, Marcelo ;
Sen, Pankaj K. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2010, 25 (03) :901-908
[8]   Contribution of variable-speed wind turbines to voltage control [J].
Ledesma, Pablo ;
Usaola, Julio .
Wind Engineering, 2002, 26 (06) :347-358
[9]  
Meegahapola L., 2012, Proceedings of 2012 IEEE 15th International Conference on Harmonics and Quality of Power (ICHQP), P612, DOI 10.1109/ICHQP.2012.6381178
[10]  
Meegahapola L., 2010, POWER ENERGY SOC GEN, P1