Computer-aided detection of pulmonary nodules:: influence of nodule characteristics on detection performance

被引:48
作者
Marten, K
Engelke, C
Seyfarth, T
Grillhösl, A
Obenauer, S
Rummeny, EJ
机构
[1] Tech Univ Munich, Dept Radiol, Munich, Germany
[2] Univ Gottingen, Dept Radiol, Gottingen, Germany
[3] Siemens Med Solut, Forchheim, Germany
关键词
computed tomography (CT); thin-section computers; diagnostic aid; image processing; lung; nodule; diagnostic radiology; observer performance;
D O I
10.1016/j.crad.2004.05.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate prospectively the influence of pulmonary nodule characteristics on detection performances of a computer-aided diagnosis (CAD) tool. and experienced chest radiologists using multislice CT (MSCT). MATERIALS AND METHODS: MSCT scans of 20 consecutive patients were evaluated by a CAD system and two independent chest radiologists for presence of pulmonary nodules. Nodule size, position, margin, matrix characteristics, vascular and pleural. attachments and reader confidence were recorded and data compared with an independent standard of reference. Statistical analysis for predictors influencing nodule detection or reader performance included chi-squared, retrograde stepwise conditional logistic regression with odds ratios and nodule detection proportion estimates (DPE), and ROC analysis. RESULTS: For 135 nodules, detection rates for CAD and readers were 76.3, 52.6 and 52.6%, respectively; false-positive rates were 0.55, 0.25 and 0.15 per examination, respectively. In consensus with CAD the reader detection rate increased to 93.3%, and the false-positive rate dropped to 0.1/scan. DPEs for nodules less than or equal to5 mm were significantly higher for ICAD than for the readers (p < 0.05). Absence of vascular attachment was the only significant predictor of nodule detection by CAD (p = 0.0006-0.008). There were no predictors of nodule detection for reader consensus with CAD. In contrast, vascular attachment predicted nodule detection by the readers (p = 0.0001-0.003). Reader sensitivity was higher for nodules with vascular attachment than for unattached nodules (sensitivities 0.768 and 0.369; 95% confidence intervals = 0.651-0.861 and 0.253-0.498, respectively). CONCLUSION: CAD increases nodule detection rates, decreases false-positive rates and compensates for deficient reader performance in detection of smallest lesions and of nodules without vascular attachment. (C) 2005 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:196 / 206
页数:11
相关论文
共 32 条
[1]   Computerized detection of pulmonary nodules on CT scans [J].
Armato, SG ;
Giger, ML ;
Moran, CJ ;
Blackburn, JT ;
Doi, K ;
MacMahon, H .
RADIOGRAPHICS, 1999, 19 (05) :1303-1311
[2]   Lung cancer: Performance of automated lung nodule detection applied to cancers missed in a CT screening program [J].
Armato, SG ;
Li, F ;
Giger, ML ;
MacMahon, H ;
Sone, S ;
Doi, K .
RADIOLOGY, 2002, 225 (03) :685-692
[3]   Automated detection of lung nodules in CT scans: Preliminary results [J].
Armato, SG ;
Giger, ML ;
MacMahon, H .
MEDICAL PHYSICS, 2001, 28 (08) :1552-1561
[4]   Pulmonary nodules at chest CT: Effect of computer-aided diagnosis on radiologists' detection performance [J].
Awai, K ;
Murao, K ;
Ozawa, A ;
Komi, M ;
Hayakawa, H ;
Hori, S ;
Nishimura, Y .
RADIOLOGY, 2004, 230 (02) :347-352
[5]   PULMONARY NODULES - IMPROVED DETECTION WITS VASCULAR SEGMENTATION AND EXTRACTION WITH SPIRAL CT [J].
CROISILLE, P ;
SOUTO, M ;
COVA, M ;
WOOD, S ;
AFEWORK, Y ;
KUHLMAN, JE ;
ZERHOUNI, EA .
RADIOLOGY, 1995, 197 (02) :397-401
[6]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[7]   Screening for early lung cancer with low-dose spiral CT: Prevalence in 817 asymptomatic smokers [J].
Diederich, S ;
Wormanns, D ;
Semik, M ;
Thomas, M ;
Lenzen, H ;
Roos, N ;
Heindel, W .
RADIOLOGY, 2002, 222 (03) :773-781
[8]  
Fan L, 2002, RADIOLOGY, V225, P475
[9]   Automatic detection of lung nodules from multi-slice low-dose CT images [J].
Fan, L ;
Novak, CL ;
Qian, JZ ;
Kohl, G ;
Naidich, DP .
MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 :1828-1835
[10]   Automatic detection of pulmonary nodules in low-dose screening thoracic CT examinations [J].
Fiebich, M ;
Wietholt, C ;
Renger, BC ;
Armato, SG ;
Hoffmann, KR ;
Wormanns, D ;
Diederich, S .
MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 :1434-1439