Transjugular Intrahepatic Portosystemic Shunt Flow Reduction with Adjustable Polytetrafluoroethylene-Covered Balloon-Expandable Stents Using the "Sheath Control" Technique

被引:15
作者
Blue, Robert C. [1 ]
Lo, Grace C. [1 ]
Kim, Edward [1 ]
Patel, Rahul S. [1 ]
Nowakowski, F. Scott [1 ]
Lookstein, Robert A. [1 ]
Fischman, Aaron M. [1 ]
机构
[1] Icahn Sch Med Mt Sinai, Dept Radiol, Intervent Radiol Sect, Box 1234,One Gustave Levy Pl, New York, NY 10029 USA
关键词
REFRACTORY HEPATIC-ENCEPHALOPATHY; HOURGLASS STENT; MANAGEMENT; INSERTION; GRAFTS;
D O I
10.1007/s00270-015-1249-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A complication of transjugular intrahepatic portosystemic shunts (TIPS) placement is refractory portosystemic encephalopathy (PSE) often requiring TIPS reduction. We report the results of a "sheath control technique" utilizing constraining sheaths during deployment of polytetrafluoroethylene (PTFE)-covered balloon-expandable stents, minimizing stent migration, and providing additional procedural control. TIPS reduction was performed in 10 consecutive patients for PSE using Atrium iCast covered stents (Atrium Maquet Getinge Group, Germany). Within the indwelling TIPS stent, a 9 mm x 59 mm iCast stent was deployed with 2 cm exposed from the sheath's distal end and the majority of the stent within the sheath to create the distal hourglass shape. During balloon retraction, the stent was buttressed by the sheath. The proximal portion of the stent was angioplastied to complete the hourglass configuration, and the central portion of the stent was dilated to 5 mm. Demographics, pre- and post-procedure laboratory values, and outcomes were recorded. Ten patients underwent TIPS reduction with 100 % technical success. There was no stent migration during stent deployment. All patients experienced initial improvement of encephalopathy. One patient ultimately required complete TIPS occlusion for refractory PSE, and another developed TIPS occlusion 36 days post-procedure. There was no significant trend toward change in patients' MELD scores immediately post-procedure or at 30 days (p = 0.46, p = 0.47, respectively). TIPS reduction using Atrium iCast PTFE balloon-expandable stents using the "sheath control technique" is safe and effective, and minimizes the risk of stent migration.
引用
收藏
页码:935 / 939
页数:5
相关论文
共 11 条
[1]   Comparison of transjugular intrahepatic portosystemic shunt dysfunction in PTFE-covered stent-grafts versus bare stents [J].
Barrio, J ;
Ripoll, C ;
Bañares, R ;
Echenagusia, A ;
Catalina, MV ;
Camúñez, F ;
Simó, G ;
Santos, L .
EUROPEAN JOURNAL OF RADIOLOGY, 2005, 55 (01) :120-124
[2]   Clearing the Confusion over Hepatic Encephalopathy After TIPS Creation: Incidence, Prognostic Factors, and Clinical Outcomes [J].
Casadaban, Leigh C. ;
Parvinian, Ahmad ;
Minocha, Jeet ;
Lakhoo, Janesh ;
Grant, Christopher W. ;
Ray, Charles E., Jr. ;
Knuttinen, M. Grace ;
Bui, James T. ;
Gaba, Ron C. .
DIGESTIVE DISEASES AND SCIENCES, 2015, 60 (04) :1059-1066
[3]   Management of Refractory Hepatic Encephalopathy After Insertion of TIPS: Long-Term Results of Shunt Reduction With Hourglass-Shaped Balloon-Expandable Stent-Graft [J].
Fanelli, Fabrizio ;
Salvatori, Filippo Maria ;
Rabuffi, Paolo ;
Boatta, Emanuele ;
Riggio, Oliviero ;
Lucatelli, Pierleone ;
Passariello, Roberto .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (06) :1696-1702
[4]   A modified procedure for transjugular intrahepatic portosystemic shunt flow reduction [J].
Jacquier, Alexis ;
Vidal, Vincent ;
Monnet, Olivier ;
Varoquaux, Arthur ;
Gaubert, Jean-Yves ;
Champsaur, Pierre ;
Gerolami, Rene ;
Bartoli, Jean-Michel ;
Moulin, Guy .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (08) :1359-1363
[5]   Transjugular Intrahepatic Portosystemic Shunt Flow Reduction with Adjustable Polytetrafluoroethylene-covered Balloon-expandable Stents [J].
Kroma, Ghazwan ;
Lopera, Jorge ;
Cura, Marco ;
Suri, Rajeev ;
El-Merhi, Fadi ;
Reading, Jerad .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (07) :981-986
[6]   2-YEAR OUTCOME FOLLOWING TRANSJUGULAR INTRAHEPATIC PORTOSYSTEMIC SHUNT FOR VARICEAL BLEEDING - RESULTS IN 90 PATIENTS [J].
LABERGE, JM ;
SOMBERG, KA ;
LAKE, JR ;
GORDON, RL ;
KERLAN, RK ;
ASCHER, NL ;
ROBERTS, JP ;
SIMOR, MM ;
DOHERTY, CA ;
HAHN, J ;
BACCHETTI, P ;
RING, EJ .
GASTROENTEROLOGY, 1995, 108 (04) :1143-1151
[7]  
Madoff David C, 2005, Semin Intervent Radiol, V22, P316, DOI 10.1055/s-2005-925558
[8]   Management of transjugular intrahepatic portosystemic shunt-induced refractory hepatic encephalopathy with the parallel technique: Results of a clinical follow-up study [J].
Maleux, Geert ;
Heye, Sam ;
Verslype, Chris ;
Nevens, Fredrik .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 18 (08) :986-993
[9]   Successful treatment of TIPS-induced hepatic failure with an hourglass stent-graft: A simple new technique for reducing shunt flow [J].
Quaretti, P ;
Michieletti, E ;
Rossi, S .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (07) :887-890
[10]   TIPS reduction with use of stents or stent-grafts [J].
Saket, RR ;
Sze, DY ;
Razavi, MK ;
Kee, STW ;
Frisoli, JK ;
Semba, CP ;
Dake, MD .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (07) :745-751