High beat-to-beat blood pressure variability in atrial fibrillation compared to sinus rhythm

被引:36
作者
Olbers, Joakim [1 ]
Gille, Adam [1 ]
Ljungman, Petter [2 ]
Rosenqvist, Marten [2 ]
Ostergren, Jan [3 ,4 ]
Witt, Nils [1 ]
机构
[1] Karolinska Inst, Dept Clin Sci & Educ, Unit Cardiol, Sodersjukhuset, Stockholm, Sweden
[2] Karolinska Inst, Danderyd Univ Hosp, Dept Cardiol, Dept Clin Sci, Stockholm, Sweden
[3] Karolinska Inst, Karolinska Univ Hosp, Dept Med, Stockholm, Sweden
[4] Karolinska Inst, Karolinska Univ Hosp, Dept Emergency Med, Stockholm, Sweden
关键词
Atrial fibrillation; hemodynamics; blood pressure; blood pressure measurement; monitoring; atherosclerosis; blood pressure variability; SYMPATHETIC-NERVE ACTIVITY; MEAN ARTERIAL-PRESSURE; MYOCARDIAL-INFARCTION; CARDIAC-OUTPUT; RISK; IMPACT; PLAQUE;
D O I
10.1080/08037051.2018.1436400
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Purpose: Atrial fibrillation (AF) is associated with an increased risk for cardiovascular morbidity and mortality, not entirely explained by thromboembolism. The underlying mechanisms for this association are largely unknown. Similarly, high blood pressure (BP) increases the risk for cardiovascular events. Despite this the interplay between AF and BP is insufficiently studied. The purpose of this study was to examine and quantify the beat-to-beat blood pressure variability in patients with AF in comparison to a control group of patients with sinus rhythm.Materials and methods: We studied 33 patients - 21 in atrial fibrillation and 12 in sinus rhythm - undergoing routine coronary angiography. Invasive blood pressure was recorded at three locations: radial artery, brachial artery and ascending aorta. Blood pressure variability, defined as average beat-to-beat blood pressure difference, was calculated for systolic and diastolic blood pressure at each site.Results: We observed a significant difference (p<.001) in systolic and diastolic blood pressure variability between the atrial fibrillation and sinus rhythm groups at all locations. Systolic blood pressure variability roughly doubled in the atrial fibrillation group compared to the sinus rhythm group (4.9 and 2.4mmHg respectively). Diastolic beat-to-beat blood pressure variability was approximately 6 times as high in the atrial fibrillation group compared to the sinus rhythm group (7.5 and 1.2mmHg respectively). No significant difference in blood pressure variability was seen between measurement locations.Conclusions: Beat-to-beat blood pressure variability in patients with atrial fibrillation was substantially higher than in patients with sinus rhythm. Hemodynamic effects of this beat-to-beat variation in blood pressure may negatively affect vascular structure and function, which may contribute to the increased cardiovascular morbidity and mortality seen in patients with atrial fibrillation.
引用
收藏
页码:249 / 255
页数:7
相关论文
共 50 条
[21]   Standing beat-to-beat blood pressure variability is reduced among fallers in the Malaysian Elders Longitudinal Study [J].
Goh, Choon-Hian ;
Ng, Siew-Cheok ;
Kamaruzzaman, Shahrul Bahyah ;
Chin, Ai-Vyrn ;
Tan, Maw Pin .
MEDICINE, 2017, 96 (42)
[22]   Predictive Capacity of Beat-to-Beat Blood Pressure Variability for Cardioautonomic and Vascular Dysfunction in Early Metabolic Challenge [J].
Fares, Souha A. ;
Bakkar, Nour-Mounira Z. ;
El-Yazbi, Ahmed F. .
FRONTIERS IN PHARMACOLOGY, 2022, 13
[23]   Effect of nebivolol on beat-to-beat and short-term blood pressure variability in spontaneously hypertensive rats [J].
Facundo Martín Bertera ;
Julieta Sofía Del Mauro ;
Ariel Héctor Polizio ;
Diego Chiappetta ;
Carlos Alberto Taira ;
Christian Höcht .
Naunyn-Schmiedeberg's Archives of Pharmacology, 2012, 385 :833-843
[24]   Soft Wearable Pressure Sensors for Beat-to-Beat Blood Pressure Monitoring [J].
Kim, Joshua ;
Chou, En-Fan ;
Le, Jamie ;
Wong, Sabrina ;
Chu, Michael ;
Khine, Michelle .
ADVANCED HEALTHCARE MATERIALS, 2019, 8 (13)
[25]   Augmented resting beat-to-beat blood pressure variability in young, healthy, non-Hispanic black men [J].
Young, Benjamin E. ;
Kaur, Jasdeep ;
Vranish, Jennifer R. ;
Stephens, Brandi Y. ;
Barbosa, Thales C. ;
Cloud, Jane N. ;
Wang, Jing ;
Keller, David M. ;
Fadel, Paul J. .
EXPERIMENTAL PHYSIOLOGY, 2020, 105 (07) :1102-1110
[26]   A comparison of beat-to-beat blood pressure variability in acute and subacute stroke patients with cerebral infarction [J].
Robinson, T ;
WardClose, S ;
Potter, J .
CEREBROVASCULAR DISEASES, 1997, 7 (04) :214-219
[27]   Prognostic value of beat-to-beat blood pressure variability parameters in patients after mechanical thrombectomy [J].
Sun, Ying-Ying ;
Pang, Shu-Yan ;
Qu, Yang ;
Wang, Si-Ji ;
Zhu, Hong-Jing ;
Yin, Wen-Jing ;
Yang, Yi ;
Guo, Zhen-Ni .
HYPERTENSION RESEARCH, 2025, 48 (03) :1155-1162
[28]   Beat-to-beat P-wave morphology as a predictor of paroxysmal atrial fibrillation [J].
Filos, Dimitrios ;
Chouvarda, Ioanna ;
Tachmatzidis, Dimitris ;
Vassilikos, Vassilios ;
Maglaveras, Nicos .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2017, 151 :111-121
[29]   Beat-to-Beat Blood Pressure Estimation by Photoplethysmography and Its Interpretation [J].
Fleischhauer, Vincent ;
Feldheiser, Aarne ;
Zaunseder, Sebastian .
SENSORS, 2022, 22 (18)
[30]   Assessment of Beat-To-Beat Variability in Left Atrial Hemodynamics Using Real Time Phase Contrast MRI in Patients With Atrial Fibrillation [J].
DiCarlo, Amanda L. ;
Haji-Valizadeh, Hassan ;
Passman, Rod ;
Greenland, Philip ;
McCarthy, Patrick ;
Lee, Daniel C. ;
Kim, Daniel ;
Markl, Michael .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 58 (03) :763-771