High beat-to-beat blood pressure variability in atrial fibrillation compared to sinus rhythm

被引:31
|
作者
Olbers, Joakim [1 ]
Gille, Adam [1 ]
Ljungman, Petter [2 ]
Rosenqvist, Marten [2 ]
Ostergren, Jan [3 ,4 ]
Witt, Nils [1 ]
机构
[1] Karolinska Inst, Dept Clin Sci & Educ, Unit Cardiol, Sodersjukhuset, Stockholm, Sweden
[2] Karolinska Inst, Danderyd Univ Hosp, Dept Cardiol, Dept Clin Sci, Stockholm, Sweden
[3] Karolinska Inst, Karolinska Univ Hosp, Dept Med, Stockholm, Sweden
[4] Karolinska Inst, Karolinska Univ Hosp, Dept Emergency Med, Stockholm, Sweden
关键词
Atrial fibrillation; hemodynamics; blood pressure; blood pressure measurement; monitoring; atherosclerosis; blood pressure variability; SYMPATHETIC-NERVE ACTIVITY; MEAN ARTERIAL-PRESSURE; MYOCARDIAL-INFARCTION; CARDIAC-OUTPUT; RISK; IMPACT; PLAQUE;
D O I
10.1080/08037051.2018.1436400
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Purpose: Atrial fibrillation (AF) is associated with an increased risk for cardiovascular morbidity and mortality, not entirely explained by thromboembolism. The underlying mechanisms for this association are largely unknown. Similarly, high blood pressure (BP) increases the risk for cardiovascular events. Despite this the interplay between AF and BP is insufficiently studied. The purpose of this study was to examine and quantify the beat-to-beat blood pressure variability in patients with AF in comparison to a control group of patients with sinus rhythm.Materials and methods: We studied 33 patients - 21 in atrial fibrillation and 12 in sinus rhythm - undergoing routine coronary angiography. Invasive blood pressure was recorded at three locations: radial artery, brachial artery and ascending aorta. Blood pressure variability, defined as average beat-to-beat blood pressure difference, was calculated for systolic and diastolic blood pressure at each site.Results: We observed a significant difference (p<.001) in systolic and diastolic blood pressure variability between the atrial fibrillation and sinus rhythm groups at all locations. Systolic blood pressure variability roughly doubled in the atrial fibrillation group compared to the sinus rhythm group (4.9 and 2.4mmHg respectively). Diastolic beat-to-beat blood pressure variability was approximately 6 times as high in the atrial fibrillation group compared to the sinus rhythm group (7.5 and 1.2mmHg respectively). No significant difference in blood pressure variability was seen between measurement locations.Conclusions: Beat-to-beat blood pressure variability in patients with atrial fibrillation was substantially higher than in patients with sinus rhythm. Hemodynamic effects of this beat-to-beat variation in blood pressure may negatively affect vascular structure and function, which may contribute to the increased cardiovascular morbidity and mortality seen in patients with atrial fibrillation.
引用
收藏
页码:249 / 255
页数:7
相关论文
共 50 条
  • [1] BEAT-TO-BEAT VARIABILITY IS ATTENUATED IN SINUS TACHYCARDIA AS COMPARED TO SINUS RHYTHM
    GAYLE, DD
    FITZGERALD, DM
    HAISTY, WK
    SIMMONS, TF
    CROSSLEY, GH
    CLINICAL RESEARCH, 1993, 41 (04): : A781 - A781
  • [2] Beat-to-beat Systolic as Well as Diastolic Blood Pressure Variability is High in Atrial Fibrillation
    Olbers, Joakim
    Gille, Adam
    Ostergren, Jan
    Ljungman, Petter
    Rosenqvist, Marten
    Witt, Nils
    CIRCULATION, 2015, 132
  • [3] The Effect of Medication on P-wave Beat-to-Beat Variability in Atrial Fibrillation during Sinus Rhythm
    Filos, Dimitris
    Tachmatzidis, Dimitris
    Vassilikos, Vassilios
    Chouvarda, Ionanna
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 5578 - 5581
  • [4] Ambulatory and beat-to-beat blood pressure variability: Are they related?
    Sloan, RP
    Shapiro, PA
    Bagiella, E
    McKinley, PS
    Myers, MM
    Brondolo, EN
    Eichler, B
    PSYCHOSOMATIC MEDICINE, 2001, 63 (01): : 172 - 172
  • [5] Prediction Of Atrial Fibrillation From Beat-To-Beat Correlations During Normal Rhythm
    Rasanen, Esa
    Pukkila, Teemu
    Molkkari, Matti
    CIRCULATION, 2024, 150
  • [6] Beat-to-Beat Blood Pressure Variability and Cognition in the MIDUS Study
    Sweigert, Joshua
    McKinley, Paula
    Lachman, Margie
    Gruenewald, Tara
    Seeman, Teresa
    Love, Gayle
    Weinstein, Maxine
    McIntyre, Kathleen
    Duong, Jimmy
    Sloan, Richard P.
    PSYCHOSOMATIC MEDICINE, 2017, 79 (04): : A154 - A155
  • [7] Reliability of beat-to-beat blood pressure variability in older adults
    Lohman, Trevor
    Sible, Isabel J.
    Shenasa, Fatemah
    Engstrom, Allison C.
    Kapoor, Arunima
    Alitin, John Paul M.
    Gaubert, Aimee
    Thayer, Julian F.
    Ferrer, Farrah
    Nation, Daniel A.
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [8] BEAT-TO-BEAT VARIABILITY OF HEART INTERVAL AND BLOOD PRESSURE.
    De Boer, Roel W.
    Karemaker, John M.
    Strackee, Jan
    1600, (04):
  • [9] Beat-to-Beat Patterning of Sinus Rhythm Reveals Non-linear Rhythm in the Dog Compared to the Human
    Meise, N. Sydney
    Flanders, Wyatt H.
    Pariaut, Romain
    FRONTIERS IN PHYSIOLOGY, 2020, 10
  • [10] Beat-to-beat QT dynamics in paroxysmal atrial fibrillation
    Larroude, Charlotte E.
    Jensen, Berit T.
    Agner, Erik
    Toft, Egon
    Torp-Pedersen, Christian
    Wachtell, Kristian
    Kanters, Jorgen K.
    HEART RHYTHM, 2006, 3 (06) : 660 - 664