Effect of central corneal thickness on dynamic contour tonometry and goldmann applanation tonometry in primary open-angle glaucoma

被引:34
作者
Grieshaber, Matthias C. [1 ]
Schoetzau, Andreas [1 ]
Zawinka, Claudia [1 ]
Flammer, Josef [1 ]
Orgul, Selim [1 ]
机构
[1] Univ Basel Hosp, Dept Ophthalmol, CH-4031 Basel, Switzerland
关键词
D O I
10.1001/archopht.125.6.740
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To compare the dependence of dynamic contour tonometry ( DCT) and Goldmann applanation tonometry ( GAT) on central corneal thickness ( CCT) in primary open-angle glaucoma. Methods: In a prospective study, the interocular ( right vs left eye) difference in intraocular pressure measured by DCT and GAT was compared with the interocular CCT difference in 125 patients with primary open-angle glaucoma. Results: Dynamic contour tonometry measurements ( mean +/- SD, 19.4 +/- 4.1 mm Hg) were significantly ( P = .004) higher than GAT measurements ( mean +/- SD, 15.5 +/- 3.4 mm Hg), correlating significantly with each other ( r(2) = 0.82, P < .001). The interocular difference in intraocular pressure correlated significantly with the interocular CCT difference for GAT ( r = 0.30, P = .001) and DCT ( r = 0.23, P = .02) readings. Dynamic contour tonometry and GAT intraocular pressure differences significantly increased with older age ( slope, 0.033 [ 95% confidence interval, 0.002-0.064] mm Hg/y; P = .03) but not with thicker CCT ( slope, 0.006 [ 95% confidence interval, -0.003 to 0.017] mm Hg/mu m; P = .22). Conclusions: In this series, GAT and DCT measurements were dependent on CCT in patients with primary open-angle glaucoma. Because intraocular pressure differences between DCT and GAT were independent of CCT, DCT and GAT are susceptible to similar measurement biases depending on CCT.
引用
收藏
页码:740 / 744
页数:5
相关论文
共 41 条
[11]  
GOLDMANN H, 1957, Ophthalmologica, V134, P221
[12]  
Gordon MO, 2002, ARCH OPHTHALMOL-CHIC, V120, P714
[13]   Increased corneal thickness in patients with ocular hypertension [J].
Herman, DC ;
Hodge, DO ;
Bourne, WM .
ARCHIVES OF OPHTHALMOLOGY, 2001, 119 (03) :334-336
[14]   Central corneal thickness as a risk factor for advanced glaucoma damage [J].
Herndon, LW ;
Weizer, JS ;
Stinnett, SS .
ARCHIVES OF OPHTHALMOLOGY, 2004, 122 (01) :17-21
[15]   Central corneal thickness in normal, glaucomatous, and ocular hypertensive eyes [J].
Herndon, LW ;
Choudhri, SA ;
Cox, T ;
Damji, KF ;
Shields, MB ;
Allingham, RR .
ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (09) :1137-1141
[16]   Effects of antiglaucoma drops on MMP and TIMP balance in conjunctival and subconjunctival tissue [J].
Ito, T ;
Ohguro, H ;
Mamiya, K ;
Ohguro, I ;
Nakazawa, M .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (03) :823-830
[17]   Dynamic contour tonometry for intraocular pressure measurement [J].
Kamppeter, BA ;
Jonas, JB .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (02) :318-320
[18]   Dynamic contour tonometry - Presentation of a new tonometer [J].
Kanngiesser, HE ;
Kniestedt, C ;
Robert, YCA .
JOURNAL OF GLAUCOMA, 2005, 14 (05) :344-350
[19]   Comparison of dynamic contour tonometry with Goldmann applanation tonometry [J].
Kaufmann, C ;
Bachmann, LM ;
Thiel, MA .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (09) :3118-3121
[20]   Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis [J].
Kaufmann, C ;
Bachmann, LM ;
Thiel, MA .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (09) :3790-3794