Solenoid micropump-based flow system for generalized calibration strategy

被引:12
|
作者
Wieczorek, Marcin [1 ]
Koscielniak, Pawel [1 ]
Swit, Pawel [1 ]
Paluch, Justyna [1 ]
Kozak, Joanna [1 ]
机构
[1] Jagiellonian Univ, Fac Chem, Dept Analyt Chem, PL-30060 Krakow, Poland
关键词
Analytical calibration; Flow analysis; Generalized calibration strategy; Atomic absorption spectrometry; COMPLEMENTARY DILUTION METHOD;
D O I
10.1016/j.talanta.2014.04.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Generalized calibration strategy (GCS) is one of the innovative approaches aimed at verification and improvement of accuracy of analytical determinations. It combines in a single procedure the interpolative and the extrapolative calibration approaches along with stepwise dilution of a sample with the use of a dedicated flow system. In the paper a simple solenoid micropump-based flow system designed for implementation of GCS has been described. The manifold consists of several modules fully operated by a computer and connected with each other in a properly designed network. Its performance and usefulness were tested on determination of calcium by FAAS in synthetic and natural samples containing strong interferents. It was shown how GCS can serve for detection, examination and elimination of the interference effects. It was demonstrated that the designed manifold enabled to perform GCS procedure with very good precision, in short time and with very low standard, sample and reagent consumption. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:21 / 26
页数:6
相关论文
共 41 条
  • [1] Novel Approach to Two-Component Analysis Based on the Generalized Calibration Strategy
    Chocholous, Petr
    Wieczorek, Marcin
    Swit, Pawel
    Kozak, Joanna
    Solich, Petr
    Koscielniak, Pawel
    ANALYTICAL LETTERS, 2017, 50 (04) : 617 - 628
  • [2] Generalized Calibration Strategy in Analytical Chemistry
    Koscielniak, Pawel
    Wieczorek, Marcin
    Kozak, Joanna
    Herman, Magorzata
    ANALYTICAL LETTERS, 2011, 44 (1-3) : 411 - 430
  • [3] A single standard calibration module for flow analysis systems based on solenoid microdevices
    Tymecki, Lukasz
    Strzelak, Kamil
    Koncki, Robert
    TALANTA, 2009, 79 (02) : 205 - 210
  • [4] A multicommutated flow system based on an opened-loop with micropump propulsion
    Rodrigues, Eunice R. G. O.
    Lapa, Rui A. S.
    Lima, Jose L. F. C.
    ANALYTICAL LETTERS, 2007, 40 (08) : 1632 - 1645
  • [5] Flow analysis-based fast-moving flow calibration for a people-counting system
    Jae Hyeon Park
    Sung In Cho
    Multimedia Tools and Applications, 2021, 80 : 31671 - 31685
  • [6] Flow analysis-based fast-moving flow calibration for a people-counting system
    Park, Jae Hyeon
    Cho, Sung In
    MULTIMEDIA TOOLS AND APPLICATIONS, 2021, 80 (21-23) : 31671 - 31685
  • [7] A multicommuted flow system with solenoid micro-pumps for paraquat determination in natural waters
    Infante, Carlos M. C.
    Morales-Rubio, A.
    de la Guardia, M.
    Rocha, Fabio R. P.
    TALANTA, 2008, 75 (05) : 1376 - 1381
  • [8] Simple flow system for calibration by the standard addition method
    Koscielniak, P
    Herman, M
    CHEMIA ANALITYCZNA, 1999, 44 (04): : 773 - 784
  • [9] White calibration methods based on gradient techniques as a modern approach to quantitative flow analysis
    Koscielniak, Pawel
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2022, 157
  • [10] A new flow injection calibration system based on automatic diagnosis and correction for fault peak signal using flow injection gradient information
    Fan, SH
    Fang, ZL
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (09) : 1038 - 1041