Effects of a digital filter on detectability of a phantom lesion in a scintigram of the equine tarsus

被引:7
作者
Eksell, P
Carlsson, S
Lord, P
Carlsten, J
机构
[1] Swedish Univ Agr Sci, Fac Vet Med, Dept Clin Radiol, S-75007 Uppsala, Sweden
[2] Uddevala Hosp, Dept Med Phys, Uddevalla, Sweden
关键词
nuclear medicine; equine; scintigraphy; digital filter; image processing;
D O I
10.1111/j.1740-8261.2000.tb02089.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The aim of this study was to examine the effects of a digital filter on the detectability of a phantom lesion in a scintigram of the equine tarsus, Lateral images containing 50, 100, 150, 500, or 1000 kcounts were acquired. A created phantom lesion of 0 (normal), 10, 15, 20, or 30% increased intensity relative to local background was placed in the centrodistal tarsal joint area in the images of different count levels. Duplicate images were filtered with a Metz filter. The complete set of filtered and unfiltered images totaling 180 images was projected as slides to a group of 9 observers. The sensitivity in 50 and 100 kcount images was improved by applying the filter, Digital filtering increased the false positive fraction at all count levels but this effect was most pronounced in 500 and 1000 kcount images. Based on receiver operating characteristic analysis, filtering of a 50 kcount image improved image quality to that of a 150 kcount image.
引用
收藏
页码:365 / 370
页数:6
相关论文
共 17 条
  • [1] CHAMBERS MD, 1995, J AM VET MED ASSOC, V206, P792
  • [2] DANIEL GB, 1996, HDB VET NUCL MED, V25, P49
  • [3] DEVOUS MD, 1984, J AM VET MED ASSOC, V184, P318
  • [4] EVAN ALI, 1981, MED PHYSICS HDB, V10, P80
  • [5] HANLEY JA, 1989, CRIT REV DIAGN IMAG, V29, P307
  • [6] THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE
    HANLEY, JA
    MCNEIL, BJ
    [J]. RADIOLOGY, 1982, 143 (01) : 29 - 36
  • [7] HANLEY JA, 1991, MED IMAGING, V5
  • [8] SCINTIGRAPHIC EVALUATION OF SKELETAL DISEASE AND ITS APPLICATION TO THE HORSE
    LAMB, CR
    KOBLIK, PD
    [J]. VETERINARY RADIOLOGY, 1988, 29 (01): : 16 - 27
  • [9] LORD P, 1999, VET RADIOL ULTRASOUN, V40, P203
  • [10] MILLER TR, 1982, J NUCL MED, V23, P66