Chandelier Illumination for Descemet Membrane Endothelial Keratoplasty

被引:8
作者
Shimizu, Toshiki [1 ,2 ]
Hayashi, Takahiko [1 ,2 ]
Yuda, Kentaro [1 ,2 ]
Tsuchiya, Ayako [1 ,2 ]
Oyakawa, Itaru [3 ,4 ]
Mizuki, Nobuhisa [2 ]
Kato, Naoko [5 ]
机构
[1] Yokohama Minami Kyosai Hosp, Dept Ophthalmol, Yokohama, Kanagawa 2360037, Japan
[2] Yokohama City Univ, Sch Med, Dept Ophthalmol, Yokohama, Kanagawa, Japan
[3] Heart Life Hosp, Dept Ophthalmol, Nakagami Dist, Okinawa, Japan
[4] Univ Ryukyus, Dept Ophthalmol, Nishihara, Okinawa, Japan
[5] Saitama Med Univ, Dept Ophthalmol, Saitama, Japan
关键词
Descemet membrane endothelial keratoplasty; endothelial keratoplasty; chandelier illuminator; shallow anterior chamber; bullous keratopathy; GENERATION IMAGING MICROSCOPY; BULLOUS KERATOPATHY; DMEK; SECONDARY; SURGEONS; GRAFT;
D O I
10.1097/ICO.0000000000001254
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To describe a simple technique that uses posterior chandelier illumination during Descemet membrane endothelial keratoplasty in cases of severe bullous keratopathy (BK). Methods: Five eyes of 4 patients with advanced BK undergoing Descemet membrane endothelial keratoplasty were retrospectively analyzed. The pupil of the host eye was not treated with mydriatic or miotic agents. The chandelier illuminator was inserted transconjunctivally into the vitreous cavity from the pars plana. Results: In all eyes, BK was secondary to laser iridotomy, which was performed for prevention or treatment of angle closure glaucoma. The implanted graft was clearly confirmed in the anterior chamber using activated chandelier illumination. The graft was immediately attached to the host cornea, with eventual healing of BK in all eyes. No complication involving insertion or removal of the 25-gauge trocar and the chandelier illuminator was observed. No vision-threatening complication was observed in any of the 5 eyes. Conclusions: The chandelier illuminator provided good visibility of the anterior chamber and enhanced the safety of surgery by preventing formation of an inverted graft.
引用
收藏
页码:1155 / 1157
页数:3
相关论文
共 28 条
[1]   Descemet Membrane Endothelial Keratoplasty: Preliminary Results of a Donor Insertion Pull-through Technique Using a Donor Mat Device [J].
Ang, Marcus ;
Mehta, Jodhbir S. ;
Newman, Stephen D. ;
Han, Sang Beom ;
Chai, Jean ;
Tan, Donald .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 171 :27-34
[2]   Impact of introducing 2 simple technique modifications on the Descemet membrane endothelial keratoplasty learning curve [J].
Arnalich-Montiel, Francisco ;
Perez-Sarriegui, Ane ;
Casado, Alfonso .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (01) :16-20
[3]   A Method to Confirm Correct Orientation of Descemet Membrane During Descemet Membrane Endothelial Keratoplasty [J].
Bachmann, Bjoern O. ;
Laaser, Kathrin ;
Cursiefen, Claus ;
Kruse, Friedrich E. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 149 (06) :922-925
[4]   Handheld Slit Beam Techniques to Facilitate DMEK and DALK [J].
Burkhart, Zachary N. ;
Feng, Matthew T. ;
Price, Marianne O. ;
Price, Francis W. .
CORNEA, 2013, 32 (05) :722-724
[5]   Standardized "No-Touch" Technique for Descemet Membrane Endothelial Keratoplasty [J].
Dapena, Isabel ;
Moutsouris, Kyros ;
Droutsas, Konstantinos ;
Ham, Lisanne ;
van Dijk, Korine ;
Melles, Gerrit R. J. .
ARCHIVES OF OPHTHALMOLOGY, 2011, 129 (01) :88-94
[6]   Impact of Surgical Learning Curve in Descemet Membrane Endothelial Keratoplasty on Visual Acuity Gain [J].
Debellemaniere, Guillaume ;
Guilbert, Emmanuel ;
Courtin, Romain ;
Panthier, Christophe ;
Sabatier, Patrick ;
Gatinel, Damien ;
Saad, Alain .
CORNEA, 2017, 36 (01) :1-6
[7]  
Dirisamer M, 1960, ARCH OPHTHALMOL-CHIC, V2012, P280
[8]   Descemet's Membrane Endothelial Keratoplasty Prospective Study of 1-Year Visual Outcomes, Graft Survival, and Endothelial Cell Loss [J].
Guerra, Frederico P. ;
Anshu, Arundhati ;
Price, Marianne O. ;
Giebel, Arthur W. ;
Price, Francis W. .
OPHTHALMOLOGY, 2011, 118 (12) :2368-2373
[9]   Descemet membrane endothelial keratoplasty (DMEK) for Fuchs endothelial dystrophy: review of the first 50 consecutive cases [J].
Ham, L. ;
Dapena, I. ;
van Luijk, C. ;
van der Wees, J. ;
Melles, G. R. J. .
EYE, 2009, 23 (10) :1990-1998
[10]   Chandelier Illumination for Use During Descemet Stripping Automated Endothelial Keratoplasty in Patients With Advanced Bullous Keratopathy [J].
Inoue, Tomoyuki ;
Oshima, Yusuke ;
Hori, Yuichi ;
Maeda, Naoyuki ;
Nishida, Kohji .
CORNEA, 2011, 30 :S50-S53