Predictors of perforation during lead extraction: Results of the Canadian Lead ExtrAction Risk (CLEAR) study

被引:13
作者
Bashir, Jamil [1 ,2 ]
Lee, Arthur J. [1 ,2 ]
Philippon, Francois [3 ]
Mondesert, Blandine [4 ]
Krahn, Andrew D. [1 ,2 ]
Sadek, Mouhannad M. [5 ]
Exner, Derek [6 ]
Pak, Melissa [1 ,2 ]
Legare, Jean Francois [7 ,8 ]
Karim, Shahzad [1 ,2 ]
Fedoruk, Lynn [1 ,2 ]
Peng, Defen [1 ,2 ]
Cusimano, Robert J. [9 ]
Parkash, Ratika [7 ,8 ]
Tyers, G. Frank O. [1 ,2 ]
Andrade, Jason [1 ,2 ]
机构
[1] Univ British Columbia, Div Cardiovasc Surg, Vancouver, BC, Canada
[2] Univ British Columbia, Div Cardiol, Vancouver, BC, Canada
[3] Inst Univ Cardiol & Pneumol Quebec, Div Cardiol, Quebec City, PQ, Canada
[4] Montreal Heart Inst, Div Cardiol, Montreal, PQ, Canada
[5] Univ Ottawa, Div Cardiol, Heart Inst, Ottawa, ON, Canada
[6] Univ Calgary, Div Cardiol, Calgary, AB, Canada
[7] Dalhousie Univ, Div Cardiac Surg, Halifax, NS, Canada
[8] Dalhousie Univ, Div Cardiol, Halifax, NS, Canada
[9] Univ Toronto, Div Cardiovasc Surg, Toronto, ON, Canada
关键词
Complications; Defibrillator; Lead extraction; Pacemaker; Tamponade; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; TRANSVENOUS EXTRACTION; PACEMAKER; MORTALITY;
D O I
10.1016/j.hrthm.2021.10.019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Transvenous lead extraction can have serious adverse events, such as cardiac or vascular perforation. Risk factors have not been well characterized. OBJECTIVE The purpose of this study was to identify factors associated with perforation and death, and to characterize lead extraction in a large contemporary population. METHODS We performed a retrospective multicenter study examining patients undergoing lead extraction at 8 Canadian institutions from 1996 through 2016. Demographic and clinical data were used to identify variables associated with perforation and mortality using logistic regression modeling. RESULTS A total of 2325 consecutive patients (age 61.9 +/- 16.5 years) underwent extraction of 4527 leads. Perforation rate was 2.7% (63/2325) and 30-day mortality was 1.6% (38/2325), with mortality of 0.4% due to perforation (10/2325). Variables associated with perforation included no previous cardiac surgery (odds ratio [OR] 3.33; 95% confidence interval [CI] 1.54-7.19; P = .002), female sex (OR 3.27; 95% CI 1.91-5.60; P<.001); left ventricular ejection fraction >= 40% (OR 2.81; 95% CI 1.28-6.14; P =.010); lead age >8 years (OR 2.64; 95% CI 1.52-4.60; P<.001); >= 2 leads extracted (OR 2.49; 95% CI 1.23-5.04; P = .011); and diabetes (OR 2.12; 95% CI 1.16-3.86; P = .014). Variables associated with death included infection as indication for extraction (OR 3.85; 95% CI 1.38-10.73; P = .010); anemia (OR 3.14; 95% CI 1.38-6.61; P = .003), and patient age (OR 1.04; 95% CI 1.01-1.07; P = .012). CONCLUSION Risk factors associated with perforation in lead extraction include no history of cardiac surgery, female sex, preserved left ventricular ejection fraction, lead age >8 years, >= 2 leads extracted, and diabetes.
引用
收藏
页码:1097 / 1103
页数:7
相关论文
共 20 条
  • [1] RIsk Stratification prior to lead Extraction and impact on major intraprocedural complications (RISE protocol)
    Afzal, Muhammad R.
    Daoud, Emile G.
    Matre, Nancy
    Shoben, Abigail
    Burnside, Melissa
    Gilliam, Courtney
    Pinkhas, Daniel
    Okabe, Toshimasa
    Tyler, Jaret
    Houmsse, Mahmoud
    Kalbfleisch, Steven S.
    Crestanello, Juan A.
    Turner, Katja
    Weiss, Raul
    Hummel, John D.
    Love, Charles J.
    Augostini, Ralph S.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (11) : 2453 - 2459
  • [2] Compliant endovascular balloon reduces the lethality of superior vena cava tears during transvenous lead extractions
    Azarrafiy, Ryan
    Tsang, Darren C.
    Boyle, Thomas A.
    Wilkoff, Bruce L.
    Carrillo, Roger G.
    [J]. HEART RHYTHM, 2017, 14 (09) : 1400 - 1404
  • [3] Classification and Surgical Repair of Injuries Sustained During Transvenous Lead Extraction
    Bashir, Jamil
    Fedoruk, Lynn M.
    Ofiesh, John
    Karim, Shahzad S.
    Tyers, G. Frank O.
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2016, 9 (09)
  • [4] The European Lead Extraction ConTRolled (ELECTRa) study: a European Heart Rhythm Association (EHRA) Registry of Transvenous Lead Extraction Outcomes
    Bongiorni, Maria Grazia
    Kennergren, Charles
    Butter, Christian
    Deharo, Jean Claude
    Kutarski, Andrzej
    Rinaldi, Christopher A.
    Romano, Simone L.
    Maggioni, Aldo P.
    Andarala, Maryna
    Auricchio, Angelo
    Kuck, Karl-Heinz
    Blomstrom-Lundqvist, Carina
    [J]. EUROPEAN HEART JOURNAL, 2017, 38 (40) : 2995 - 3005
  • [5] Nomogram for predicting 30-day all-cause mortality after transvenous pacemaker and defibrillator lead extraction
    Brunner, Michael P.
    Yu, Changhong
    Hussein, Ayman A.
    Tarakji, Khaldoun G.
    Wazni, Oussama M.
    Kattan, Michael W.
    Wilkoff, Bruce L.
    [J]. HEART RHYTHM, 2015, 12 (12) : 2381 - 2386
  • [6] Outcomes of patients requiring emergent surgical or endovascular intervention for catastrophic complications during transvenous Lead extraction
    Brunner, Michael P.
    Cronin, Edmond M.
    Wazni, Oussama
    Baranowski, Bryan
    Saliba, Walid I.
    Sabik, Joseph F.
    Lindsay, Bruce D.
    Wilkoff, Bruce L.
    Tarakji, Khaldoun G.
    [J]. HEART RHYTHM, 2014, 11 (03) : 419 - 425
  • [7] Transvenous extraction of implantable cardioverter-defibrillator leads under advisory-A comparison of Riata, Sprint Fidelis, and non-recalled implantable cardioverter-defibrillator leads
    Brunner, Michael P.
    Cronin, Edmond M.
    Jacob, Jessen
    Duarte, Valeria E.
    Tarakji, Khaldoun G.
    Martin, David O.
    Callahan, Thomas
    Borek, P. Peter
    Cantillon, Daniel J.
    Niebauer, Mark J.
    Saliba, Walid I.
    Kanj, Mohamed
    Wazni, Oussama
    Baranowski, Bryan
    Wilkoff, Bruce L.
    [J]. HEART RHYTHM, 2013, 10 (10) : 1444 - 1450
  • [8] Pathways for training and accreditation for transvenous lead extraction: a European Heart Rhythm Association position paper
    Deharo, J. C.
    Bongiorni, M. G.
    Rozkovec, A.
    Bracke, F.
    Defaye, P.
    Fernandez-Lozano, I.
    Golzio, P. G.
    Hansky, B.
    Kennergren, C.
    Manolis, A. S.
    Mitkowski, P.
    Platou, E. S.
    Love, C.
    Wilkoff, B.
    [J]. EUROPACE, 2012, 14 (01): : 124 - 134
  • [9] Deaths and cardiovascular injuries due to device-assisted implantable cardioverter-defibrillator and pacemaker lead extraction
    Hauser, Robert G.
    Katsiyiannis, William T.
    Gornick, Charles C.
    Almquist, Adrian K.
    Kallinen, Linda M.
    [J]. EUROPACE, 2010, 12 (03): : 395 - 401
  • [10] Safety and effectiveness of transvenous extraction of pacemaker and implantable cardioverter-defibrillator leads in patients under or over 80 years of age
    Kempa, Maciej
    Budrejko, Szymon
    Piepiorka, Marta
    Rogowski, Jan
    Raczak, Grzegorz
    Kozlowski, Dariusz
    [J]. KARDIOLOGIA POLSKA, 2013, 71 (02) : 130 - 135