Current Control of Grid-Connected Inverter With LCL Filter Based on Extended-State Observer Estimations Using Single Sensor and Achieving Improved Robust Observation Dynamics

被引:98
|
作者
Wang, Baochao [1 ,2 ]
Xu, Yongxiang [2 ]
Shen, Zhaoyuan [2 ]
Zou, Jibin [1 ,2 ]
Li, Chaoquan [3 ]
Liu, Hong [4 ,5 ]
机构
[1] Harbin Inst Technol, State Key Lab Robot & Syst, Harbin 150001, Peoples R China
[2] Harbin Inst Technol, Sch Elect Engn & Automat, Harbin 150001, Peoples R China
[3] NORINCO, Nav & Control Inst, Beijing 100089, Peoples R China
[4] Harbin Inst Technol, Sch Mechatron Engn, Harbin 150001, Peoples R China
[5] Harbin Inst Technol, State Key Lab Robot & Syst, Harbin 150001, Peoples R China
基金
中国国家自然科学基金;
关键词
Active damping; extended state observer (ESO); grid-connected inverter; grid synchronization; independent of expertise tuning; LCL filter; observer dynamic decoupling; parameter mismatch; single sensor; CONVERTERS;
D O I
10.1109/TIE.2017.2674600
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In the context of distributed generation and renewable energy penetration toward smart grid, grid-connected inverter with LCL filter has drawn many attentions, whose current control conventionally requires several sensors to realize active damping and grid synchronization. In this paper, a novel full status observation strategy based on extended state observer (ESO) is proposed using inverter current feedback only and without grid voltage sensor. The proposed observation strategy contains observation and transformation process. Unlike conventional Luenberger observer, by using ESO, the system parameters do not appear in observation process, thus the observer dynamics and parameter mismatch error can be separately handled, providing more robust observation dynamics during parameter variation. Parameter mismatch study was carried out, and it is found that purposely choosing the observer parameters smaller than the real value can achieve relatively low estimation error and a large adaption range for parameter variation. The proposed observation strategy is simple to implement, without the need of expert knowledge-based parameter tuning such as pole placement. Experimental tests validated that the proposed observation-based control is able to give satisfactory performance in both dynamic and steady states, as well as adaption for system parameter variation.
引用
收藏
页码:5428 / 5439
页数:12
相关论文
共 50 条
  • [41] Observer-Based State-Space Current Control for a Three-Phase Grid-Connected Converter Equipped With an LCL Filter
    Kukkola, Jarno
    Hinkkanen, Marko
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 1371 - 1378
  • [42] Indirect Current Control Method Based on Reference Current Compensation of an LCL-Type Grid-Connected Inverter
    Li, Zheng
    Yang, Linhang
    Yang, Daliang
    Peng, Zuwen
    Shao, Dashuai
    Liu, Jinbao
    ENERGIES, 2022, 15 (03)
  • [43] Improved DPWM Scheme for Improvement of Grid Current Quality in a Large-Scale Grid-Connected Inverter System with a LCL-Filter
    Park, JinHyuk
    Lee, Kyo-Beum
    2015 IEEE CONFERENCE ON ENERGY CONVERSION (CENCON), 2015, : 343 - 348
  • [44] Design of passivity-based stabilized control of grid-connected inverter system with LCL filter
    Kato, Toshiji
    Inoue, Kaoru
    Nakajima, Yusuke
    Yamamoto, Yuki
    ELECTRICAL ENGINEERING IN JAPAN, 2019, 207 (02) : 49 - 58
  • [45] Design of passivity-based stabilized control of grid-connected inverter system with LCL filter
    Kato T.
    Inoue K.
    Nakajima Y.
    Yamamoto Y.
    IEEJ Transactions on Industry Applications, 2019, 139 (01) : 93 - 101
  • [46] ROBUST CONTROL STRATEGY OF LCL-TYPE GRID-CONNECTED INVERTER BASED ON DELAY COMPENSATION
    Liang J.
    Kong F.
    Wang Z.
    Li X.
    Ding X.
    Chen Y.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2023, 44 (12): : 444 - 452
  • [47] Robust Suppression Strategy for Photovoltaic Grid-Connected Inverter Cluster Resonance Based on Kalman Filter Improved Disturbance Observer
    He, Guofeng
    Yan, Cheng
    Zhou, Zichun
    Lin, Junfang
    Li, Guojiao
    ENERGIES, 2022, 15 (21)
  • [48] Quasi-Notch-Filter-Based Highly Robust Active Damping for LCL-Filtered Grid-Connected Inverter
    Su, Guoxing
    Xu, Lin
    Wang, Xuehua
    He, Yuying
    Liu, Fuxin
    2020 IEEE 11TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG), 2020, : 376 - 381
  • [49] Dual Closed-Loop Control Strategy of LCL Filter Grid-Connected Inverter Based on the αβ Coordinate System
    Huang, Zuxun
    Liu, Yitao
    Wang, Huaizhi
    Wang, Guibin
    Yin, Jian
    Peng, Jianchun
    2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 1181 - 1186
  • [50] Sliding mode control for a single-phase grid-connected H-bridge NPC inverter with a LCL filter
    Cengiz, Muhammet
    Duman, Turgay
    COMPUTERS & ELECTRICAL ENGINEERING, 2024, 117